Mesh
Showing 17–18 of 18 results
Showing 17–18 of 18 results
This page lists all 18 Mesh replacement filters available from Metal Air Filters — precision-manufactured washable aluminum mesh filters engineered as direct OEM replacements for Carrier commercial HVAC equipment. All filters on this page are HI Series products manufactured by American Metal Filter Company (AMFCO) with .030" extruded aluminum alloy frames, corrugated aluminum mesh media, UL 900 Class 1 certification, and a 275°F maximum operating temperature rating.
Each filter is a permanent washable replacement — clean and reuse for 5–10 years rather than replacing disposable filters every 30–90 days. AMFCO’s aluminum mesh construction provides 43% average dust arrestance per ASHRAE 52.1, making these filters ideal pre-filters in multi-stage Carrier commercial HVAC systems protecting downstream MERV 8 through HEPA filtration stages in rooftop units, air handlers, and split systems.
Create a free online account during checkout to instantly receive 10% off your first order. Registered customers also enjoy exclusive benefits including 15% off all repeat orders, priority processing, order history tracking, and expedited reordering. Set up your account by clicking the “Create account?” checkbox during checkout. Commercial and institutional accounts may qualify for NET 30 payment terms with approved credit application.
All 18 Carrier-compatible washable aluminum mesh replacement filters available from Metal Air Filters, with nominal size, actual dimensions, and current pricing. Click any part number for full product details, specifications, and purchasing.
The following specifications apply to the HI Series aluminum mesh filters on this page. Individual products vary by nominal size, actual dimensions, dust holding capacity, and OEM compatibility — see each product page for complete product-specific specifications.
| Specifications: | Details: |
|---|---|
| Frame Material | .030” thick aluminum |
| Frame Construction | Precision-mitered corners secured with pop rivets; 3/8” diameter drain holes along bottom of frame |
| Filter Type | Impingement type washable panel filter |
| Rated Airflow | 500 fpm face velocity |
| Recommended Airflow Range | 450–550 fpm |
| Maximum Operating Temperature | 275°F continuous |
| Recommended Final Resistance | 0.50 inches W.G. before cleaning |
| Washability | Frequent and moderate |
| Compliance & Certifications | UL Classified 900 |
| Country of Origin | Made in USA |
Carrier commercial HVAC equipment is deployed across a wide range of commercial, institutional, and industrial building types. The following applications represent the primary use cases for Mesh permanent washable aluminum mesh filters.
The HMAS100500-1-20.5x23x1 20.5x23x1 aluminum mist eliminator filter delivers reliable performance across commercial, institutional, and light industrial environments where airborne moisture, water droplets, oil mist, or coolant mist must be separated from the airstream to protect downstream HVAC equipment, prevent corrosion and biological growth, and maintain system performance. The impingement-type aluminum screen wire construction, 275°F temperature rating, and all-aluminum corrosion resistance make this filter suitable for continuous operation in demanding applications that would degrade or destroy lower-rated filter alternatives.
Commercial and institutional buildings’ outside air intake systems subject HVAC equipment to rain entrainment, wind-driven water, morning dew, and seasonal precipitation that introduce liquid water into ductwork and air handling equipment. The HMAS100500-1-20.5x23x1 installed at outside air intake locations captures water droplets before they reach fan sections, coils, controls, and downstream filter banks, preventing moisture accumulation that causes rust, corrosion, biological growth, and equipment failure. Commercial office buildings, hospitals, schools, and institutional facilities with outside air systems in coastal, humid, or precipitation-prone climates benefit from the HMAS100500-1-20.5x23x1’s 99%+ capture efficiency on 3-micron and larger water droplets, combined with the passive gravity drainage system that continuously removes captured moisture during normal HVAC operation without operator intervention. Building engineers specifying outdoor air system protection rely on the HM Series mist eliminator’s long service history and verifiable test data to meet ventilation system performance requirements and equipment warranty conditions.
Chilled water coil sections in commercial air handling units generate condensate during normal cooling operation, and coil surfaces can become sites for airborne moisture accumulation that migrates downstream when airflow velocity exceeds the coil’s carry-over limit. Installing the HMAS100500-1-20.5x23x1 downstream of chilled water coil sections captures carried-over moisture droplets before they reach supply ductwork, fan sections, and terminal equipment, protecting investments in downstream components and preventing moisture-related indoor air quality problems. Data centers, server rooms, precision manufacturing facilities, healthcare environments, and other applications with strict humidity control requirements benefit from the HMAS100500-1-20.5x23x1’s combination of high-efficiency moisture capture and heavy-duty washable particulate filtration in a single permanent panel filter unit that installs in standard 20.5x23x1 nominal side-access or built-up filter bank positions.
Steam and evaporative humidifier systems introduce moisture into airstreams to maintain required relative humidity levels in commercial buildings, data centers, healthcare facilities, museums, and manufacturing environments where humidity control is critical for occupant comfort, process control, or material preservation. Improperly positioned or oversized humidifiers can introduce unevaporated water droplets into ductwork that cause corrosion, biological growth, and moisture damage to insulation and finishes downstream. Installing the HMAS100500-1-20.5x23x1 downstream of mist-type humidifier discharge points captures unevaporated droplets before they enter distribution ductwork, providing a reliable safeguard against water damage from humidifier over-injection events while also providing heavy-duty particulate filtration of the humidified supply air stream.
Light industrial manufacturing operations using coolant mist delivery systems, metalworking equipment, or process cooling generate oil mist and coolant aerosols that must be captured before entering building HVAC systems or exhausting to outside air. The HMAS100500-1-20.5x23x1’s impingement-type aluminum screen wire construction captures oil mist and coolant aerosol droplets through the same mechanism it uses for water droplets, collecting the captured liquid in the frame and draining it by gravity when installed upright. Industrial ventilation engineers specifying mist control for machining centers, stamping operations, and cooling tower exhaust applications select the HM Series aluminum mist eliminator for its 275°F temperature rating, all-aluminum construction compatible with coolant chemistry, and heavy-duty washable design that withstands the frequent and rigorous cleaning demanded by industrial operating environments. The HMAS100500-1-20.5x23x1 handles the demanding conditions of industrial mist control applications that would rapidly degrade electrostatic, pleated, or cardboard-framed filter alternatives.
Customers searching for metal mesh air filters, air filter mesh, metal mesh filter, metal filter, “metal mesh air filter”, and metal filter mesh will find all compatible washable aluminum mesh replacement filters on this page. All mesh products shown here are manufactured by American Metal Filter Company (AMFCO) as permanent, washable OEM replacements for Carrier commercial HVAC equipment. Whether searching for metal mesh air filters by Carrier part number or by nominal size, each filter shown here ships directly from AMFCO with full compatibility documentation.
The HMAS100500-1-20.5x23x1 operates on the impingement principle: water droplets and oil mist cannot follow the tortuous path through the 9-ply aluminum screen wire media layers at 500 fpm and collide with wire surfaces where surface tension holds captured liquid until it drains through the 3/8″ bottom drain holes. Achieves 99%+ efficiency on 3-micron+ water droplets.
Rinse with a moderate-to-heavy stream of warm water from the clean side through to the dirty side until water runs clear. High-powered steam cleaning and chemical dips are not recommended. Air dry or shake off excess water before reinstalling. Filter Coat adhesive may optionally be reapplied after each wash if adhesive treatment is used.
The 3/8″ drain holes are along the bottom of the frame and only function when the filter is upright with TOP facing up. Installing sideways or inverted prevents captured moisture from draining, reducing separation efficiency and potentially causing liquid re-entrainment into the airstream.
The HMAS100500-1-20.5x23x1 HMA aluminum model is rated for 275°F continuous operation. For higher temperatures, AMFCO offers HMG galvanized (325°F) and HMS stainless steel (900°F) variants in the same HM Series.
Actual dimensions: 20.5″ H x 23.0″ W x 0.875″ D (±1/8″ H&W, ±1/16″ depth). Nominal size: 20.5x23x1. HM Series uses 5/8″ undercut on height and width—not 1/2″ as used by some other filter series.
Yes—the HM Series aluminum mist eliminator may optionally be sprayed with Filter Coat, a water-soluble adhesive and detergent, before installation to enhance particulate capture. Filter Coat washes off during routine cleaning and must be reapplied after each wash cycle if desired.
Yes—the HM Series may be supplied with polyurethane gaskets on the vertical sides of the frame for side-access housing applications requiring a moisture-tight seal. Specify ‘with gaskets’ and indicate which dimensions (short or long side) require gaskets when ordering.
Wash frequency depends on application: outside air intakes in dusty environments typically every 1–3 months; commercial moisture separation applications every 3–6 months; industrial coolant mist applications may need monthly washing. Inspect visually and monitor drain hole flow as indicators for washing timing.
HMA (.030″ aluminum frame, 24 ga aluminum face grids): 275°F max, frequent and moderate washability. HMG (24 ga galvanized steel): 325°F max, frequent and rigorous washability. HMS (24 ga stainless steel, stainless screen wire): 900°F max. All use aluminum screen wire media except HMS. Contact Metal Air Filters for HMG or HMS if your application requires higher temperature ratings.
The HMAS100500-1-20.5x23x1 is designed for commercial and industrial HVAC systems operating at 500 fpm (450–550 fpm recommended range)—higher than standard residential airflow. It fits 20.5x23x1 nominal filter positions in outside air ducts, side-access housings, and built-up filter banks. Verify your system airflow is within range for optimal moisture separation performance.