Custom Mesh Filter, Galvanized Steel, 1 Inch Thick
As low as $0.12 per sq inch
Please provide actual L x W measurements down to the 1/16th inch. Example: “15.25 x 24.1875”. Custom size filters are not returnable so please double check before ordering.
| 1/16 = .0625 | 9/16″ = .5625 |
| 1/8 = .125 | 5/8″ = .625 |
| 3/16 = .1875 | 11/16″ = .6875 |
| 1/4 = .25 | 3/4″ = .75 |
| 5/16 = .3125 | 13/16″ = .8125 |
| 3/8 = .375 | 7/8″ = .875 |
| 7/16 = .4375 | 15/16″ = .9375 |
| 1/2 = .5 | 1″ = 1 |
Description
Product Overview
The HIGS10 Custom 1″ Galvanized Steel Washable Mesh Filter delivers industrial-grade filtration performance for HVAC systems requiring enhanced durability, corrosion resistance, and elevated temperature capability in custom dimensions that off-the-shelf products cannot provide. This made-to-order 1″ nominal depth (7/8″ actual) galvanized steel mesh filter combines 24-gauge hot-dip galvanized steel frame construction with 5-ply corrugated criss-cross screen wire media, providing 325°F continuous temperature capability and superior corrosion resistance for humid industrial environments, commercial laundries, food processing facilities, and applications where standard aluminum construction proves inadequate. Built to UL 900 Class 1 standards with custom manufacturing to your exact dimensional specifications, this galvanized steel filter ensures reliable pre-filtration performance tailored precisely to your unique HVAC system needs while withstanding conditions that would degrade aluminum alternatives.
Engineered with precision-formed 24-gauge galvanized steel frames paired with specialized 5-ply corrugated aluminum screen wire media and 30-gauge galvanized steel face grids, the HIGS10 delivers 43% dust arrestance efficiency in the industry-standard 1″ nominal depth profile. This industrial-grade configuration serves environments requiring enhanced moisture resistance and elevated temperature handling—from commercial kitchens operating at elevated ambient temperatures to manufacturing facilities with high humidity levels where aluminum filters experience premature corrosion. Custom-manufactured to your exact specifications in the USA, each filter ships ready to install with no modifications required, providing permanent filtration for discontinued equipment, non-standard installations, and harsh industrial applications demanding materials that maintain structural integrity beyond aluminum’s capabilities.
Unlike disposable filters requiring constant replacement—especially problematic for custom sizes with discontinued or non-standard dimensions—this custom galvanized steel washable mesh filter delivers 5-10 years of continuous service with proper maintenance protocols. The robust hot-dip galvanized construction features precision-mitered corners secured with galvanized pop rivets and 30-gauge galvanized steel face grids ensuring structural integrity through repeated cleaning cycles using standard water-based methods. Three strategically placed corner drain holes facilitate complete water removal after washing, preventing moisture retention and accelerating return-to-service time. Once you’ve placed your initial custom order, reordering identical replacements is effortless through your online account, ensuring you’ll never struggle to find the right filter size again while maintaining the enhanced durability and temperature capability that galvanized steel provides.
Facility managers, property owners, and HVAC contractors working with industrial environments, elevated temperature applications, humid conditions, or equipment requiring enhanced corrosion resistance rely on custom galvanized steel washable mesh filters to solve filtration challenges where aluminum construction falls short. Whether you’re maintaining commercial kitchen ventilation systems with grease-laden airstreams and elevated temperatures, supporting manufacturing facilities with high humidity and potential corrosive atmospheres, servicing food processing plants requiring frequent washdown environments, or managing commercial laundries operating at sustained elevated temperatures, the HIGS10 provides a permanent solution manufactured to your exact specifications. With 325°F continuous temperature rating, superior corrosion resistance compared to aluminum, low initial airflow resistance, and the ability to maintain peak performance through repeated cleaning cycles, this custom galvanized steel washable mesh filter delivers measurable ROI through eliminated filter replacement costs, extended service life in demanding conditions, and the peace of mind that comes from having a reliable long-term filtration solution precisely matched to your system dimensions and operating environment.
Key Benefits of the HIGS10 Custom 1″ Galvanized Steel Washable Mesh Filter
- Industrial-Grade Galvanized Steel Construction: 24-gauge hot-dip galvanized steel frame with 30-gauge galvanized steel face grids provides enhanced corrosion resistance and structural integrity in humid, corrosive, or elevated temperature environments where aluminum construction degrades prematurely.
- 325°F Continuous Temperature Rating: 50°F higher operating temperature than aluminum construction serves commercial kitchens, manufacturing facilities, and industrial applications with sustained elevated ambient temperatures that exceed aluminum’s 275°F limitation.
- Custom Sizing for Any HVAC System: Made-to-order manufacturing accommodates any height and width combination, solving filtration challenges for discontinued equipment, industrial systems, and non-standard installations where off-the-shelf galvanized filters don’t fit.
- Superior Moisture & Humidity Resistance: Hot-dip galvanized coating provides exceptional rust resistance in humid environments, frequent washdown operations, and moisture-rich atmospheres where aluminum oxidation becomes problematic.
- Industry-Standard 1″ Nominal Depth: 7/8″ actual depth fits the vast majority of commercial and industrial HVAC filter tracks, providing optimal balance of dust-holding capacity and airflow resistance in galvanized steel custom-sized package.
- Effortless Reordering: Once you’ve placed your initial custom order, reordering identical galvanized steel filters is simple through your online account—no need to re-measure or re-specify dimensions for future purchases.
Technical Specifications
The HIGS10 Custom 1″ Galvanized Steel Washable Mesh Filter represents precision-engineered filtration technology manufactured to your exact dimensional specifications with industrial-grade galvanized steel construction. This industry-standard 1″ nominal depth (7/8″ actual) galvanized mesh pre-filter delivers exceptional performance validated through rigorous UL 900 Class 1 testing, ensuring reliable operation in continuous high-temperature and corrosive environments up to 325°F. Every custom filter is built with the same industrial-grade construction standards as our stock HIG Series products, providing the enhanced durability and corrosion resistance you expect from hot-dip galvanized steel construction with dimensions tailored precisely to your unique HVAC system requirements.
Manufactured in the USA using premium 24-gauge galvanized steel framing paired with 5-ply corrugated criss-cross aluminum screen wire media and 30-gauge galvanized steel face grids, this custom washable mesh filter meets the stringent requirements of industrial and commercial HVAC applications requiring non-standard filter dimensions with enhanced environmental resistance. The 1″ nominal (7/8″ actual) depth profile ensures compatibility with the vast majority of HVAC filter tracks while the 43% dust arrestance efficiency protects downstream equipment from premature loading. With 68 grams per square foot dust-holding capacity, this custom galvanized steel filter extends cleaning intervals and reduces maintenance frequency in applications where finding replacement filters has historically been challenging and where material durability directly impacts service life.
| Specifications: | Details: |
|---|---|
| Model Number | HIGS10 (Custom 1″ Galvanized Steel) |
| Filter Depth | 1″ nominal (7/8″ actual depth) |
| Height & Width | Custom dimensions manufactured to your exact specifications |
| Dimensional Tolerance | ±1/8″ on height and width |
| Frame Material | 24-gauge hot-dip galvanized steel |
| Filter Media | 5-ply corrugated criss-cross aluminum screen wire mesh |
| Face Grid Material | 30-gauge galvanized steel |
| Frame Construction | Precision-mitered corners, galvanized pop rivets |
| Drainage | 3 corner drain holes for complete water removal after washing |
| Maximum Operating Temperature | 325°F continuous (UL 900 Class 1 certified) |
| Dust Arrestance Efficiency | 43% average at rated airflow (350 FPM) |
| Dust Holding Capacity | 68 grams per square foot |
| Rated Airflow | 350 FPM (feet per minute) |
| Recommended Airflow Range | 300-500 FPM face velocity |
| Initial Pressure Drop | 0.08″ w.g. @ 350 FPM (clean filter) |
| Recommended Final Resistance | 0.50″ w.g. (water gauge) before cleaning |
| Weight | Varies by custom dimensions (heavier than aluminum, lighter than stainless) |
| Washability | Repeated cleaning cycles with water-based methods, detergents, or pressure washers |
| Service Life | 5-10 years with proper maintenance protocols |
| Compliance & Certifications | UL 900 Class 1, ASTM E 2931 (washable filter standard) |
| Country of Origin | Made in USA |
Industrial & Specialized Applications
The HIGS10 Custom 1″ Galvanized Steel Washable Mesh Filter solves critical filtration challenges across industrial and commercial applications where enhanced corrosion resistance, elevated temperature capability, and structural durability exceed aluminum’s limitations while custom dimensions accommodate unique HVAC equipment requirements. From humid manufacturing environments to commercial kitchens operating at sustained elevated temperatures, this galvanized steel solution ensures reliable pre-filtration when standard materials and standard sizes cannot meet your system’s combined dimensional and environmental demands.
Commercial Kitchen & Food Service Equipment
Commercial kitchens, restaurants, and food processing facilities operate HVAC systems exposed to elevated ambient temperatures, grease-laden airstreams, high humidity, and frequent washdown protocols that accelerate aluminum corrosion and compromise structural integrity. The HIGS10’s 325°F continuous temperature rating and superior galvanized steel corrosion resistance serve ventilation systems for commercial ovens, dishwasher hood exhaust, prep area ventilation, and walk-in cooler/freezer condensing units where temperatures regularly exceed aluminum’s 275°F capability and where moisture exposure demands enhanced rust protection. Restaurant chains maintaining older HVAC equipment with discontinued filter dimensions, institutional kitchens in schools and hospitals with non-standard ventilation configurations, and food processing plants requiring custom-sized pre-filtration for specialized equipment depend on galvanized steel construction to maintain filtration performance throughout years of demanding service. The permanent washable construction means once you’ve established your custom dimensions and experienced galvanized steel’s superior durability in your specific application, reordering identical replacements through your online account ensures consistent filtration performance without the frustration of searching for compatible custom-sized alternatives.
Manufacturing & Industrial Facilities
Industrial manufacturing environments—including textile mills, printing operations, chemical processing plants, and general manufacturing facilities—subject HVAC filtration systems to elevated temperatures, high humidity levels, chemical vapor exposure, and particulate loading that compromise aluminum filter longevity. The HIGS10’s hot-dip galvanized steel construction provides exceptional corrosion resistance in humid industrial atmospheres while the 325°F temperature rating protects against heat degradation in facilities where aluminum frames would warp or oxidize prematurely. Plastics manufacturing facilities with thermoforming operations generating sustained elevated temperatures, commercial laundries operating with continuous steam and humidity exposure, printing plants with solvent vapor atmospheres, and automotive shops with paint booth ventilation systems rely on galvanized steel filters when equipment dimensions require custom manufacturing and when operating conditions demand materials exceeding aluminum’s environmental limitations. The 5-10 year service life with proper maintenance delivers exceptional ROI in industrial applications where filter accessibility challenges make frequent replacements costly and where galvanized steel’s enhanced durability directly reduces maintenance labor and system downtime.
Humid & Moisture-Rich Environments
Applications involving sustained high humidity, frequent condensation, or regular washdown procedures benefit from galvanized steel’s superior rust resistance compared to aluminum construction. Indoor swimming pool dehumidification systems, greenhouse climate control equipment, car wash facility ventilation, commercial dishwashing hood exhaust, and coastal facilities exposed to salt-laden air experience accelerated aluminum oxidation that galvanized steel’s protective zinc coating effectively prevents. The HIGS10 serves these moisture-rich applications with custom dimensions matching discontinued equipment specifications while providing corrosion resistance that extends service life significantly beyond aluminum alternatives. Facility managers maintaining aquatic centers with older HVAC systems using non-standard filter sizes, greenhouse operators requiring custom filtration for European-manufactured climate control equipment, and car wash operations supporting legacy ventilation systems depend on galvanized steel construction to maintain structural integrity through years of moisture exposure. The washable design means repeated cleaning cycles—even with aggressive detergents required in these environments—don’t compromise the galvanized coating’s protective properties, ensuring the filter maintains both dimensional accuracy and corrosion resistance throughout its service life.
Discontinued Equipment & Legacy Industrial Systems
Industrial facilities maintaining older equipment face compounded challenges when original manufacturers discontinue filter production AND when operating environments require galvanized steel’s enhanced durability rather than standard aluminum construction. Vintage commercial rooftop units serving manufacturing facilities, legacy industrial ventilation systems with non-standard dimensions, European-manufactured industrial HVAC equipment using metric sizing, and specialty industrial applications with custom filter requirements benefit from the HIGS10’s combination of made-to-order dimensional flexibility and industrial-grade galvanized steel construction. The custom manufacturing process ensures exact dimensional match to original specifications while galvanized steel provides the corrosion resistance and temperature capability required by industrial operating conditions. Once you’ve specified your custom dimensions and confirmed galvanized steel performance in your specific environment, future reorders through your online account maintain consistent filtration capability without the perpetual frustration of searching for compatible custom-sized industrial-grade replacement filters.
Material Selection Guide
The HIGS10 features industrial-grade galvanized steel construction specifically engineered for applications requiring enhanced corrosion resistance and elevated temperature capability beyond aluminum’s limitations. Understanding when galvanized steel provides optimal value—compared to cost-effective aluminum or premium stainless steel—ensures maximum service life, performance, and return on investment based on your specific operating environment.
HIG: Galvanized Steel Construction (Industrial Grade)
The galvanized steel construction features 24-gauge hot-dip galvanized steel frame construction with 5-ply aluminum screen wire media and 30-gauge galvanized steel face grids, delivering enhanced corrosion resistance and elevated 325°F temperature capability at moderate cost increase over aluminum. The protective zinc coating applied through hot-dip galvanizing process provides exceptional rust resistance in humid environments, moisture-rich atmospheres, and applications involving frequent washdown or cleaning protocols. Choose galvanized steel when your application involves moderately elevated temperatures (275-325°F), humid environments requiring enhanced rust resistance, industrial settings where aluminum might corrode prematurely, or when the 50°F higher temperature rating provides necessary safety margin over aluminum construction. Galvanized filters excel in commercial laundries, printing facilities, food processing plants, humid industrial environments, manufacturing operations, commercial kitchens, and applications where aluminum’s environmental limitations compromise service life but full stainless steel protection isn’t required. The 5-10 year service life matches aluminum duration but delivers this longevity in significantly more demanding conditions—making galvanized steel the optimal value choice for harsh environments where aluminum fails prematurely.
HIA: Aluminum Construction (Standard Grade)
Aluminum construction with .030″ thick aluminum alloy frames provides the most cost-effective filtration solution for standard commercial and residential HVAC applications with normal indoor temperatures and dry environments. With 275°F continuous temperature rating and excellent corrosion resistance in non-humid conditions, aluminum serves the majority of HVAC environments at lowest initial cost. Consider upgrading to galvanized steel (HIGS10) when your application involves temperatures approaching or exceeding 275°F, sustained high humidity levels, frequent moisture exposure, or when premature aluminum corrosion has shortened filter service life in your specific environment. The moderate cost increase for galvanized construction delivers substantial service life extension in demanding conditions—providing better long-term value than repeatedly replacing corroded aluminum filters.
HIS: 304 Stainless Steel Construction (Premium Grade)
304 stainless steel construction with 24-gauge stainless steel frames and all-stainless media provides maximum corrosion resistance and exceptional 900°F continuous temperature rating for the most extreme applications. Choose stainless steel over galvanized when your application involves extreme temperatures exceeding 325°F (foundries, commercial bakeries, industrial drying operations), highly corrosive chemical environments beyond galvanized steel’s capabilities, or when maximum 5-10 year service life justifies premium initial investment. For most industrial applications with elevated temperatures (275-325°F) and humid or corrosive conditions, galvanized steel (HIGS10) provides optimal balance of enhanced durability and cost-effectiveness—reserving stainless steel for truly extreme environments where galvanized steel’s 325°F rating or corrosion resistance proves inadequate. Note that service life for stainless steel is 5-10 years—the same as galvanized steel and aluminum—with stainless steel’s advantage being its ability to achieve this service life in extremely harsh environments rather than extended longevity in standard conditions.
Construction Features
The HIGS10 Custom 1″ Galvanized Steel Washable Mesh Filter is engineered with precision manufacturing techniques and industrial-grade materials that ensure every custom-sized unit meets rigorous quality standards for enhanced durability and corrosion resistance. UL 900 Class 1 certification validates continuous operation capability at 325°F, while Made in USA construction guarantees dimensional accuracy and structural integrity throughout the filter’s 5-10 year service life in demanding industrial environments.
Hot-Dip Galvanized Steel Frame Construction
The foundation of this custom filter begins with a precision-formed 24-gauge steel frame subjected to hot-dip galvanizing process, where the steel is immersed in molten zinc to create a metallurgically bonded protective coating. This galvanizing process provides superior corrosion resistance compared to aluminum’s natural oxide layer, preventing rust formation in humid environments, moisture-rich atmospheres, and applications involving frequent wet cleaning cycles. The 24-gauge thickness delivers excellent structural rigidity while the hot-dip zinc coating ensures the frame maintains dimensional stability and corrosion resistance throughout repeated thermal cycling between ambient and elevated operating temperatures up to 325°F. Professional-grade mitered corners secured with galvanized pop rivets ensure the frame maintains perfect dimensional accuracy to your custom specifications throughout repeated cleaning cycles and years of service in demanding conditions. Each custom frame is manufactured to your exact height and width requirements with ±1/8″ tolerance, ensuring precise fit without gaps or binding in your HVAC system’s filter tracks while the galvanized construction prevents the corrosion-induced dimensional changes that can compromise aluminum filter fit over time.
Optimized 5-Ply Media Pack
The filtration media consists of five layers of corrugated aluminum screen wire arranged in a precision criss-cross weave pattern specifically engineered for 1″ nominal depth applications. This 5-ply configuration achieves 43% dust arrestance efficiency while maintaining low airflow resistance of just 0.08″ w.g. at rated airflow. The aluminum media provides excellent particulate capture with lightweight construction while the galvanized steel frame and face grids deliver the enhanced structural durability and temperature capability required for industrial applications. Each layer features expanded mesh construction with carefully engineered strand spacing that captures large particulates through multiple interception stages. The corrugated structure provides increased surface area within the 1″ nominal depth while the criss-cross weave pattern ensures uniform particle distribution across the entire media pack. This engineering approach delivers effective pre-filtration performance with minimal pressure drop, protecting downstream HVAC components without overburdening system blowers—with galvanized steel construction ensuring the frame and face grids maintain structural integrity even when industrial operating conditions would compromise aluminum alternatives.
Corner Drain System
Three strategically positioned corner drain holes facilitate rapid water evacuation following cleaning operations, with typical air-drying times of 30-90 minutes depending on ambient conditions. The open mesh construction and robust galvanized steel frame design enable complete water drainage without trapped moisture in corner joints or frame channels. This drainage system prevents water pooling that could lead to odor development while the hot-dip galvanized coating ensures the frame resists corrosion even with repeated wet-dry cycles throughout the filter’s multi-year service life. The galvanized steel construction naturally resists rust formation in humid environments and moisture-rich applications, maintaining structural integrity and filtration performance through thousands of operational hours and repeated cleaning cycles—delivering consistent dimensional accuracy and reliable filtration in conditions where aluminum frames would experience oxidation and potential warping.
Galvanized Steel Face Grid Protection
Both upstream and downstream faces incorporate 30-gauge galvanized steel protective grids that shield the 5-ply media layers from physical damage during handling, installation, and operation. These galvanized steel face grids distribute incoming airflow uniformly across the entire filter surface, preventing concentrated jet streams that could damage the media structure while maintaining the low pressure drop characteristic of 1″ nominal depth filtration. The grid construction provides impact resistance against accidental contact during filter changeouts while the hot-dip galvanized coating ensures the face grids resist corrosion in humid or corrosive atmospheres where aluminum grids might oxidize. This protective layer ensures the custom-manufactured filter maintains its structural integrity and filtration performance throughout thousands of operational hours and repeated cleaning cycles, with galvanized steel construction delivering enhanced durability compared to aluminum in demanding industrial and commercial applications.
Maintenance & Cleaning Protocol
The HIGS10 Custom 1″ Galvanized Steel Washable Mesh Filter requires minimal maintenance while delivering 5-10 years of reliable service in demanding industrial and commercial environments. Unlike disposable filters that create ongoing frustration finding compatible replacements for custom sizes, this industrial-grade galvanized steel mesh filter supports repeated cleaning cycles using simple water-based methods without expensive cleaning agents or replacement costs—with hot-dip galvanized construction ensuring corrosion resistance throughout years of wet cleaning cycles.
Cleaning Methods
Four effective cleaning methods accommodate different facility capabilities and contamination levels. Garden hose cleaning provides the simplest approach, using high-pressure nozzle settings to spray both sides of the 5-ply media until water runs clear—typically sufficient for most commercial and light industrial applications. Sink or tub soaking works well for moderate contamination, submerging the filter in warm soapy water for 15-30 minutes before rinsing thoroughly (galvanized steel benefits from mild detergent and tolerates more aggressive cleaning agents than aluminum without corrosion concerns). Commercial dishwashers offer hands-free cleaning for facilities with industrial dishwashing equipment, with galvanized construction tolerating standard commercial dishwasher temperatures and detergents without degradation. Pressure washing delivers fast results for heavier contamination, using 1000-1500 PSI with warm water—galvanized steel’s robust construction tolerates higher pressure than aluminum while the protective zinc coating prevents rust formation even with repeated high-pressure wet cleaning. The hot-dip galvanized frame and face grids withstand repeated washing without corrosion or degradation, maintaining structural integrity throughout the filter’s service life while operating continuously at 325°F temperature rating.
Recommended Cleaning Frequency
Cleaning intervals depend on operating environment and particulate loading rates. Light dust environments such as standard commercial applications require quarterly cleaning every three months. Moderate industrial applications including manufacturing facilities and commercial operations benefit from monthly cleaning schedules. High-particulate industrial environments with continuous dust generation may need bi-weekly to monthly cleaning to maintain optimal system performance. Visual inspection provides the most reliable cleaning indicator—schedule cleaning when the 5-ply screen wire media appears visibly loaded with dust or when system airflow seems reduced. Monitor pressure drop across the filter if instrumentation is available, cleaning when resistance reaches 0.50″ w.g. to maintain energy-efficient system operation. In humid environments or applications involving frequent moisture exposure, inspect the galvanized steel frame periodically to verify the protective zinc coating maintains its integrity—though properly maintained galvanized filters typically show no corrosion throughout their 5-10 year service life.
Handling Considerations for Galvanized Steel Construction
Galvanized steel filters provide enhanced durability with moderate weight increase compared to aluminum construction, tolerating somewhat more aggressive handling and cleaning pressure while still benefiting from proper support during maintenance. Support larger custom sizes from underneath during cleaning and installation to prevent frame stress. The 24-gauge galvanized steel frame construction provides excellent structural rigidity, though heavier custom sizes may require two-person handling for safe installation and removal. The hot-dip galvanized coating tolerates repeated wet-dry cycles and mechanical cleaning without degradation—maintaining corrosion resistance and dimensional stability throughout years of service in demanding industrial and commercial applications. Avoid using extremely abrasive cleaning tools that might damage the protective zinc coating, though normal pressure washing, detergent cleaning, and standard handling poses no risk to properly galvanized construction.
Installation
Installing the HIGS10 Custom 1″ Galvanized Steel Washable Mesh Filter follows the same straightforward procedures as standard filters, with attention to proper orientation and secure seating to ensure optimal performance from your custom-manufactured industrial-grade filtration solution.
Pre-Installation Verification
Before installing your custom galvanized steel filter, verify the dimensions match your original specifications and that your HVAC system is completely shut down with power disconnected. Inspect the filter housing interior for accumulated dust, debris, or damage that could compromise the seal. The custom-manufactured filter should fit your housing precisely with minimal clearance—if excessive gaps exist, verify you’re installing in the correct location and orientation. Check the condition of existing gaskets or sealing surfaces, replacing worn gaskets before installing your new permanent filter. Clean the filter housing interior thoroughly with a vacuum or damp cloth to ensure optimal sealing surfaces. Locate the airflow direction arrow marked on your new custom filter frame, ensuring you understand proper orientation before installation. Note the galvanized steel construction for documentation in your maintenance records, particularly in industrial environments where tracking filter material specifications supports compliance and quality management protocols.
Installation Steps
With the HVAC system powered off and locked out, open the filter access door or remove the access panel. Carefully remove any existing filter, noting its orientation and airflow direction. Inspect your new HIGS10 custom galvanized steel filter and locate the airflow direction arrow clearly marked on the frame. The 1″ nominal (7/8″ actual) depth provides comfortable handling, though the galvanized steel construction creates slightly heavier weight than aluminum—larger custom sizes may benefit from two-person installation. Insert the filter into the housing with the airflow arrow pointing in the correct direction of air movement through your system. Press the filter firmly into place, ensuring all edges seat properly against the gasket or housing walls without forcing. The robust 24-gauge galvanized steel frame construction prevents flexing during installation while the custom dimensions create proper fit without excessive gaps around the perimeter. Secure the access door or panel, restore power, and restart system operation.
Post-Installation Verification
After system restart, listen carefully for any unusual sounds such as air whistling or rattling that might indicate improper seating. Verify proper airflow by checking that air velocity at supply registers matches expected performance levels. The low pressure drop of the 1″ nominal filter means system performance should match or exceed previous levels with comparable or better filtration. Document the installation date, custom dimensions, and galvanized steel construction specification in your maintenance records for future reordering through your online account. The 43% dust arrestance efficiency begins immediately protecting downstream HVAC components from large particulates and debris. Establish a regular inspection schedule based on your specific environmental conditions to monitor dust accumulation and maintain optimal system performance throughout the filter’s 5-10 year service life. In humid or corrosive industrial environments, the galvanized steel construction provides peace of mind that the filter will maintain structural integrity and dimensional accuracy throughout years of demanding service where aluminum alternatives might experience premature degradation.
Complementary Products
The HIGS10 Custom 1″ Galvanized Steel Washable Mesh Filter excels as a pre-filtration stage, but complete HVAC protection in multi-stage industrial systems may require complementary secondary filtration products. By combining this custom galvanized steel mesh pre-filter with specialized secondary filters, you achieve optimal air quality while protecting expensive downstream filtration equipment in demanding industrial environments.
The 43% dust arrestance efficiency of this custom 1″ galvanized steel mesh pre-filter makes it the ideal first stage for industrial filtration systems requiring custom dimensions where standard filters cannot accommodate unique equipment specifications and where operating conditions demand galvanized steel’s enhanced durability.
Custom Secondary Filtration (Galvanized Steel)
For systems requiring secondary filtration in custom dimensions with consistent galvanized steel construction:
• Custom 2″ Galvanized Steel Secondary Filter (HIGS20) – Follow your custom 1″ galvanized pre-filter with custom 2″ galvanized secondary filtration for enhanced particle capture and extended cleaning intervals while maintaining consistent material properties.
• Custom 4″ Galvanized Steel Secondary Filter (HIGS40) – 4-inch depth custom galvanized filter provides maximum dust-holding capacity after 1″ pre-filtration stage in demanding industrial applications.
Alternative Material Secondary Filters (Custom Dimensions)
For multi-stage systems with different material requirements per stage:
• Custom 1″ Stainless Steel Filter (HISS10) – Upgrade to stainless steel for secondary stage if temperatures exceed 325°F or extreme corrosion resistance required.
• Custom 2″ Aluminum Filter (HIAS20) – Cost-effective aluminum secondary stage for applications where pre-filter faces harsher conditions than downstream filtration.
Standard Galvanized Steel Filters (If Dimensions Match)
If your secondary stage uses standard dimensions:
• HIG201620 – 16x20x2 Galvanized Steel Filter – Standard 2-inch galvanized steel filter for enhanced secondary filtration in industrial applications.
• HIG201224 – 12x24x2 Galvanized Steel Filter – Stock 2-inch galvanized steel secondary filter for immediate availability.
• HIG401620 – 16x20x4 Galvanized Steel Filter – Deep 4-inch galvanized steel filtration for maximum secondary stage dust-holding capacity.
Frequently Asked Questions
Why choose galvanized steel over aluminum for custom filters?
Choose galvanized steel (HIGS10) over aluminum when your application involves elevated temperatures approaching or exceeding aluminum’s 275°F limit (galvanized steel provides 325°F continuous rating), humid environments where aluminum experiences premature corrosion, industrial settings with moisture exposure, or when previous aluminum filters have shown shortened service life due to environmental conditions. The hot-dip galvanized coating provides superior rust resistance compared to aluminum’s natural oxide layer, while the 50°F higher temperature capability serves commercial kitchens, manufacturing facilities, and industrial applications that aluminum cannot handle. The moderate cost increase over aluminum delivers substantial service life extension in demanding conditions—providing better long-term value than repeatedly replacing corroded aluminum filters.
How does galvanized steel compare to stainless steel?
Galvanized steel (HIGS10 at 325°F) provides excellent corrosion resistance and elevated temperature capability at moderate cost, serving most industrial applications effectively. Stainless steel (HISS10 at 900°F) delivers maximum corrosion resistance and extreme temperature capability but at premium cost. Choose galvanized steel for temperatures up to 325°F, humid environments, moderate corrosion exposure, and when cost-effectiveness matters. Upgrade to stainless steel only for extreme temperatures exceeding 325°F (foundries, commercial bakeries), highly corrosive chemical environments, or when maximum service life justifies premium investment. For most industrial applications, galvanized steel provides optimal balance of enhanced durability and cost-effectiveness. Both materials provide 5-10 year service life with proper maintenance—stainless steel’s advantage is achieving this lifespan in extremely harsh environments rather than extended longevity.
Can I order the same custom dimensions in different materials?
Yes, absolutely. Once you’ve specified your custom dimensions for the HIGS10 galvanized steel filter, you can order the same size in aluminum (HIAS10) for cost-effective applications or stainless steel (HISS10) for extreme conditions. Many facility managers maintain inventory in multiple materials for different zones—aluminum for standard areas, galvanized steel for humid or elevated temperature zones, stainless steel for extreme applications. Your custom dimensions are saved in your account, making it easy to reorder in the same or different materials as needs change or as you optimize material selection based on actual operating experience.
Does galvanized steel affect filtration efficiency?
No, material selection does not affect filtration performance. The HIGS10 galvanized steel filter provides identical 43% dust arrestance efficiency and 68 g/sq ft dust-holding capacity as aluminum or stainless steel construction. The 5-ply media configuration delivers the same particle capture performance regardless of frame material. Material selection affects temperature rating, corrosion resistance, weight, and cost—but not filtration efficiency. Choose galvanized steel for its enhanced environmental durability and temperature capability while achieving the same filtration performance as other materials.
Is galvanized steel washable and reusable?
Yes, the HIGS10 galvanized steel filter is designed for repeated washing and reuse throughout its 5-10 year service life. The hot-dip galvanized coating withstands repeated cleaning cycles using water-based methods, detergents, pressure washers, or commercial dishwashers without corrosion or degradation. In fact, galvanized steel’s superior rust resistance makes it more tolerant of aggressive cleaning protocols and repeated wet-dry cycles compared to aluminum—maintaining structural integrity and dimensional accuracy through years of regular washing in humid or moisture-rich applications where aluminum might experience oxidation.
How long does custom manufacturing take?
Custom galvanized steel filter manufacturing typically requires 5-10 business days from order confirmation to shipment, though production schedules may vary based on current order volume. Galvanized steel production may add 1-2 days to lead time compared to aluminum due to the hot-dip galvanizing process, but this modest lead time increase delivers substantial performance advantages in demanding applications. Rush production is available for critical applications requiring faster turnaround. We recommend ordering before your existing filter reaches end-of-service to ensure continuous filtration coverage, particularly in industrial applications where extended lead times for custom-sized galvanized steel filters might otherwise create operational challenges.
Can this replace discontinued manufacturer filters in industrial applications?
Absolutely. The HIGS10 is specifically designed to provide direct OEM replacement capability for discontinued industrial filters from any manufacturer. Simply measure your existing filter’s height, width, and depth, then specify those details when ordering your custom galvanized steel filter. Our precision manufacturing ensures your filter fits perfectly without modifications, adapter frames, or system changes—while galvanized steel construction provides enhanced durability and temperature capability that may exceed your original equipment specifications. This is particularly valuable for older industrial equipment where original aluminum filters experienced premature corrosion—upgrading to galvanized steel construction often extends service life significantly beyond original manufacturer specifications.
What maintenance does galvanized steel construction require?
Galvanized steel filters require the same simple maintenance as aluminum construction—periodic washing with water-based methods when dust accumulation becomes visible or when pressure drop reaches 0.50″ w.g. The hot-dip galvanized coating requires no special maintenance or treatment, maintaining its corrosion protection throughout the filter’s 5-10 year service life with normal cleaning protocols. Clean using garden hose, sink soaking, commercial dishwasher, or pressure washer depending on facility capabilities and contamination level. The galvanized construction tolerates aggressive cleaning methods without degradation—in fact, its superior rust resistance means you can use stronger detergents and higher pressure than aluminum without corrosion concerns. Periodic visual inspection verifies the protective zinc coating maintains integrity, though properly maintained galvanized filters typically show no corrosion throughout their service life even in humid industrial environments.
Can galvanized steel filters be used in food processing or commercial kitchens?
Yes, galvanized steel filters excel in food processing facilities, commercial kitchens, and food service applications. The 325°F continuous temperature rating handles elevated ambient temperatures from commercial ovens, dishwashers, and cooking equipment, while the hot-dip galvanized coating provides excellent corrosion resistance in humid environments with frequent washdown protocols. The galvanized steel construction tolerates aggressive cleaning with commercial detergents and sanitizers required in food service operations, maintaining structural integrity and dimensional accuracy through repeated cleaning cycles. Many commercial kitchens and food processing facilities specifically choose galvanized steel over aluminum for its enhanced durability in their demanding operating conditions—with custom dimensions solving filtration challenges when equipment uses discontinued or non-standard filter sizes.
Why Choose the HIGS10 Custom 1″ Galvanized Steel Washable Mesh Filter?
Choosing the HIGS10 Custom 1″ Galvanized Steel Washable Mesh Filter eliminates the frustration and expense of searching for compatible replacement filters for HVAC systems with discontinued or non-standard dimensions while providing industrial-grade durability, enhanced corrosion resistance, and elevated temperature capability that aluminum construction cannot match. Whether you’re maintaining commercial kitchen equipment operating at sustained elevated temperatures, supporting manufacturing facilities with high humidity and potential corrosive atmospheres, servicing food processing plants requiring frequent washdown environments, or managing industrial systems where premature aluminum corrosion has shortened filter service life, this made-to-order galvanized steel solution provides permanent filtration precisely matched to your unique dimensional requirements and demanding operating conditions. The custom manufacturing process ensures perfect dimensional fit while hot-dip galvanized steel construction ensures optimal performance and maximum service life in environments where aluminum proves inadequate.
Built to the same rigorous quality standards as our stock HIG Series products, this custom filter features precision-engineered 5-ply media construction and UL 900 Class 1 certification with 325°F continuous temperature rating—50°F higher than aluminum’s limitation. The industry-standard 1″ nominal (7/8″ actual) depth profile fits the vast majority of HVAC filter tracks while providing optimal balance of dust-holding capacity and airflow resistance. Made in USA with premium 24-gauge hot-dip galvanized steel frames and 30-gauge galvanized steel face grids, each custom filter is manufactured to your exact specifications with ±1/8″ tolerance, ensuring precise fit and optimal performance throughout its 5-10 year service life in demanding industrial and commercial applications.
The permanent washable construction delivers exceptional long-term value compared to disposable alternatives—especially critical for custom sizes where finding compatible replacements creates ongoing frustration and expense and where galvanized steel’s enhanced durability extends service life significantly beyond aluminum in harsh operating conditions. Once you’ve placed your initial custom order, reordering identical galvanized steel filters is effortless through your online account, eliminating the need to re-measure or re-specify dimensions for future purchases. The 43% dust arrestance efficiency protects downstream HVAC components while the low 0.08″ pressure drop maintains optimal system efficiency. Simple water-based cleaning every few months restores peak performance without expensive cleaning agents or professional services, with hot-dip galvanized construction supporting repeated cleaning cycles throughout the filter’s multi-year service life without corrosion or degradation.
Facility managers, property owners, HVAC contractors, and industrial maintenance professionals choose the HIGS10 when standard filters cannot solve their combined dimensional and environmental filtration challenges and when operating conditions demand materials exceeding aluminum’s limitations. From maintaining vintage industrial equipment with discontinued filter dimensions to supporting harsh manufacturing environments requiring enhanced corrosion resistance and 325°F temperature capability, this custom galvanized steel mesh filter provides the permanent solution that eliminates filter procurement frustration while delivering industrial-grade filtration performance matched to your exact dimensional and environmental requirements. Invest in a custom-manufactured filter that fits your system perfectly, uses industrial-grade materials engineered for demanding conditions, provides up to a decade of reliable service, and ensures you’ll never struggle to find compatible replacements again. Order your custom HIGS10 today and experience the confidence that comes from having a permanent filtration solution precisely matched to every aspect of your unique HVAC system requirements—with galvanized steel construction delivering the enhanced durability and temperature capability your demanding application requires.
Additional information
| Weight | 4 oz |
|---|---|
| Frame Material | Galvanized Steel |
| GTIN | 00840373527335 |
| MPN | HIGS10 |
Custom Mesh Filter, Stainless Steel, 1 Inch Thick
As low as $0.23 per sq inch
Please provide actual L x W measurements down to the 1/16th inch. Example: “15.25 x 24.1875”. Custom size filters are not returnable so please double check before ordering.
| 1/16 = .0625 | 9/16″ = .5625 |
| 1/8 = .125 | 5/8″ = .625 |
| 3/16 = .1875 | 11/16″ = .6875 |
| 1/4 = .25 | 3/4″ = .75 |
| 5/16 = .3125 | 13/16″ = .8125 |
| 3/8 = .375 | 7/8″ = .875 |
| 7/16 = .4375 | 15/16″ = .9375 |
| 1/2 = .5 | 1″ = 1 |
Description
Product Overview
The HISS10 Custom 1″ Stainless Steel Washable Mesh Filter delivers maximum harsh environment filtration performance for HVAC systems requiring exceptional corrosion resistance, extreme temperature capability, and chemical resistance in custom dimensions that off-the-shelf products cannot provide. This made-to-order 1″ nominal depth (7/8″ actual) stainless steel mesh filter combines 24-gauge Type 304 stainless steel frame construction with 5-ply corrugated criss-cross stainless steel screen wire media and 30-gauge stainless steel face grids, providing 900°F continuous temperature capability and unmatched corrosion resistance for the most extreme industrial environments, highly corrosive chemical processing facilities, foundries, commercial bakeries, and applications where galvanized steel or aluminum construction proves inadequate. Built to UL 900 Class 1 standards with custom manufacturing to your exact dimensional specifications, this premium stainless steel filter ensures reliable pre-filtration performance tailored precisely to your unique HVAC system needs while withstanding the most demanding harsh environment conditions that would compromise alternative materials.
Engineered with precision-formed 24-gauge Type 304 stainless steel frames paired with specialized 5-ply corrugated stainless steel screen wire media and 30-gauge stainless steel face grids, the HISS10 delivers 43% dust arrestance efficiency in the industry-standard 1″ nominal depth profile. This premium-grade all-stainless construction serves extreme environments requiring maximum corrosion resistance, extraordinary temperature handling capability, and chemical resistance that galvanized steel and aluminum cannot provide—from foundries operating at temperatures exceeding 325°F to chemical processing facilities with highly corrosive atmospheres to commercial bakeries with continuous elevated temperature exposure. Custom-manufactured to your exact specifications in the USA, each filter ships ready to install with no modifications required, providing permanent filtration for discontinued equipment, non-standard installations, and harsh environment applications demanding materials that maintain structural integrity and filtration performance in conditions where alternative materials fail prematurely.
Unlike disposable filters requiring constant replacement—especially problematic for custom sizes with discontinued or non-standard dimensions—this custom stainless steel washable mesh filter delivers 5-10 years of continuous service with proper maintenance protocols. The robust all-stainless construction features precision-mitered corners secured with stainless steel pop rivets and 30-gauge stainless steel face grids ensuring structural integrity through repeated cleaning cycles using standard water-based methods, aggressive detergents, and even caustic cleaning agents without corrosion concerns. Three strategically placed corner drain holes facilitate complete water removal after washing, preventing moisture retention and accelerating return-to-service time. Once you’ve placed your initial custom order, reordering identical replacements is effortless through your online account, ensuring you’ll never struggle to find the right filter size again while maintaining the maximum harsh environment capability, exceptional corrosion resistance, and extraordinary temperature handling that stainless steel provides.
Facility managers, property owners, and HVAC contractors working with extreme temperature applications, highly corrosive chemical environments, foundries, commercial bakeries, industrial drying operations, or equipment requiring maximum corrosion resistance beyond galvanized steel’s capabilities rely on custom stainless steel washable mesh filters to solve filtration challenges where alternative materials fall short. Whether you’re maintaining foundry ventilation systems operating above 325°F, supporting chemical processing facilities with corrosive vapor atmospheres, servicing commercial bakery ovens requiring continuous elevated temperature capability, or managing industrial drying operations where standard materials degrade prematurely, the HISS10 provides a permanent solution manufactured to your exact specifications. With 900°F continuous temperature rating, unmatched corrosion resistance in highly corrosive environments, low initial airflow resistance, and the ability to maintain peak performance through repeated cleaning cycles even with aggressive caustic cleaning agents, this custom stainless steel washable mesh filter delivers measurable ROI through eliminated filter replacement costs, maximum service life in the most demanding harsh environment conditions, and the peace of mind that comes from having a reliable long-term filtration solution precisely matched to your system dimensions and extreme operating environment.
Key Benefits of the HISS10 Custom 1″ Stainless Steel Washable Mesh Filter
- Premium Type 304 Stainless Steel Construction: 24-gauge Type 304 stainless steel frame with 30-gauge stainless steel face grids and all-stainless media provides maximum corrosion resistance and structural integrity in highly corrosive, extreme temperature, or chemical environments where galvanized steel and aluminum construction degrade prematurely.
- 900°F Continuous Temperature Rating: Exceptional 900°F operating temperature—575°F higher than aluminum and 575°F higher than galvanized steel—serves foundries, commercial bakeries, industrial drying operations, and extreme temperature applications that alternative materials cannot handle.
- Custom Sizing for Any HVAC System: Made-to-order manufacturing accommodates any height and width combination, solving filtration challenges for discontinued equipment, industrial systems, and non-standard installations where off-the-shelf stainless steel filters don’t fit.
- Maximum Harsh Environment Corrosion Resistance: Type 304 stainless steel provides unmatched rust and corrosion resistance in highly corrosive chemical environments, salt-laden coastal atmospheres, caustic cleaning operations, and aggressive industrial atmospheres where galvanized steel’s zinc coating would be compromised.
- Chemical Resistance & Aggressive Cleaning Tolerance: Stainless steel construction tolerates caustic cleaning agents, aggressive detergents, and corrosive cleaning protocols that would damage galvanized or aluminum alternatives—ideal for applications requiring specialized cleaning procedures.
- Effortless Reordering: Once you’ve placed your initial custom order, reordering identical stainless steel filters is simple through your online account—no need to re-measure or re-specify dimensions for future purchases.
Technical Specifications
The HISS10 Custom 1″ Stainless Steel Washable Mesh Filter represents precision-engineered filtration technology manufactured to your exact dimensional specifications with premium Type 304 stainless steel construction. This industry-standard 1″ nominal depth (7/8″ actual) stainless steel mesh pre-filter delivers exceptional performance validated through rigorous UL 900 Class 1 testing, ensuring reliable operation in continuous extreme temperature and highly corrosive environments up to 900°F. Every custom filter is built with the same premium-grade construction standards as our stock HIS Series products, providing the maximum harsh environment capability and extraordinary corrosion resistance you expect from all-stainless steel construction with dimensions tailored precisely to your unique HVAC system requirements.
Manufactured in the USA using premium 24-gauge Type 304 stainless steel framing paired with 5-ply corrugated criss-cross stainless steel screen wire media and 30-gauge stainless steel face grids, this custom washable mesh filter meets the stringent requirements of extreme industrial and commercial HVAC applications requiring non-standard filter dimensions with maximum environmental resistance. The 1″ nominal (7/8″ actual) depth profile ensures compatibility with the vast majority of HVAC filter tracks while the 43% dust arrestance efficiency protects downstream equipment from premature loading. With 68 grams per square foot dust-holding capacity, this custom stainless steel filter extends cleaning intervals and reduces maintenance frequency in applications where finding replacement filters has historically been challenging and where material durability in harsh environments directly impacts service life.
| Specifications: | Details: |
|---|---|
| Model Number | HISS10 (Custom 1″ Stainless Steel) |
| Filter Depth | 1″ nominal (7/8″ actual depth) |
| Height & Width | Custom dimensions manufactured to your exact specifications |
| Dimensional Tolerance | ±1/8″ on height and width |
| Frame Material | 24-gauge Type 304 stainless steel |
| Filter Media | 5-ply corrugated criss-cross stainless steel screen wire mesh |
| Face Grid Material | 30-gauge Type 304 stainless steel |
| Frame Construction | Precision-mitered corners, stainless steel pop rivets |
| Drainage | 3 corner drain holes for complete water removal after washing |
| Maximum Operating Temperature | 900°F continuous (UL 900 Class 1 certified) |
| Dust Arrestance Efficiency | 43% average at rated airflow (350 FPM) |
| Dust Holding Capacity | 68 grams per square foot |
| Rated Airflow | 350 FPM (feet per minute) |
| Recommended Airflow Range | 300-500 FPM face velocity |
| Initial Pressure Drop | 0.08″ w.g. @ 350 FPM (clean filter) |
| Recommended Final Resistance | 0.50″ w.g. (water gauge) before cleaning |
| Weight | Varies by custom dimensions (heavier than aluminum and galvanized) |
| Washability | Repeated cleaning cycles with water-based methods, aggressive detergents, caustic agents, or pressure washers |
| Service Life | 5-10 years with proper maintenance protocols |
| Compliance & Certifications | UL 900 Class 1, ASTM E 2931 (washable filter standard) |
| Country of Origin | Made in USA |
Industrial Applications
The HISS10 Custom 1″ Stainless Steel Washable Mesh Filter solves critical filtration challenges across extreme industrial and commercial applications where maximum corrosion resistance, extraordinary temperature capability, and chemical resistance exceed galvanized steel’s and aluminum’s limitations while custom dimensions accommodate unique HVAC equipment requirements. From foundries operating at temperatures exceeding 325°F to chemical processing facilities with highly corrosive vapor atmospheres, this premium stainless steel solution ensures reliable pre-filtration when standard materials, standard sizes, and alternative construction cannot meet your system’s combined dimensional, temperature, and harsh environment demands.
Foundries & Extreme Temperature Operations
Foundry operations, metal casting facilities, forge shops, and high-temperature manufacturing environments subject HVAC systems to continuous extreme temperatures that exceed galvanized steel’s 325°F and aluminum’s 275°F limitations. The HISS10’s exceptional 900°F continuous temperature rating serves ventilation systems for foundry operations, metal melting furnaces, forging operations, and high-temperature manufacturing processes where alternative materials would experience structural degradation, warping, or complete failure. Metal casting facilities with continuous elevated ambient temperatures, forge shops with sustained high-temperature exposure near work areas, aluminum smelting operations requiring extreme temperature capability, and specialty metal fabrication facilities with temperatures regularly exceeding 325°F depend on stainless steel construction to maintain filtration performance and structural integrity throughout years of extreme temperature service. The permanent washable construction means once you’ve established your custom dimensions and experienced stainless steel’s extraordinary temperature capability in your specific application, reordering identical replacements through your online account ensures consistent filtration performance without the frustration of searching for compatible custom-sized alternatives with adequate temperature ratings.
Commercial Bakeries & Food Processing
Commercial bakery operations, large-scale food production facilities, and industrial baking operations require HVAC filtration near commercial ovens, proofing chambers, and baking equipment operating continuously at elevated temperatures that compromise aluminum and galvanized steel materials. The HISS10’s 900°F temperature rating and food-grade Type 304 stainless steel construction serve ventilation systems for commercial bread ovens, industrial cookie production lines, large-scale baking operations, and specialty food manufacturing where oven proximity creates sustained elevated ambient temperatures. Multi-deck commercial ovens with ventilation systems exposed to radiant heat, conveyor-style industrial baking lines with continuous elevated temperature exposure, specialty bakeries with artisan ovens generating sustained high temperatures, and food production facilities requiring food-grade materials depend on stainless steel’s extraordinary temperature capability and corrosion resistance. The all-stainless construction tolerates aggressive cleaning protocols required in food production environments, maintaining structural integrity through repeated washdown cycles with food-safe sanitizers and caustic cleaning agents.
Chemical Processing & Corrosive Environments
Chemical processing facilities, pharmaceutical manufacturing operations, electroplating facilities, and industrial operations involving corrosive vapors or aggressive atmospheres require filtration materials that resist chemical attack beyond galvanized steel’s capabilities. The HISS10’s Type 304 stainless steel construction provides maximum corrosion resistance to acidic vapors, alkaline atmospheres, salt spray, chlorine exposure, and chemical environments where galvanized steel’s zinc coating would be compromised or aluminum would experience rapid degradation. Chemical manufacturing plants with acid vapor exposure, electroplating facilities with caustic fume generation, pharmaceutical production cleanrooms requiring corrosion-resistant materials, and coastal industrial facilities exposed to severe salt-laden atmospheres depend on stainless steel construction when equipment dimensions require custom manufacturing and when operating conditions demand materials exceeding galvanized steel’s and aluminum’s chemical resistance limitations. The 5-10 year service life with proper maintenance delivers exceptional ROI in corrosive applications where filter accessibility challenges make frequent replacements costly and where stainless steel’s maximum corrosion resistance directly reduces maintenance labor and premature filter replacement.
Industrial Drying Operations & Continuous Elevated Temperature
Industrial drying operations, powder coating curing ovens, paint drying systems, and manufacturing processes involving continuous elevated temperature exposure benefit from stainless steel’s 900°F rating and structural stability under sustained thermal cycling. Powder coating facilities with curing ovens generating sustained elevated ambient temperatures, industrial paint drying operations with continuous heat exposure, textile drying operations with high-temperature air handling, and specialty manufacturing requiring elevated temperature capability depend on stainless steel construction to maintain filtration performance when alternative materials would experience premature failure. The HISS10 serves these continuous elevated temperature applications with custom dimensions matching discontinued equipment specifications while providing temperature capability and structural stability that extends service life significantly beyond galvanized steel’s 325°F limitation and aluminum’s 275°F constraint. Facility managers maintaining industrial drying systems with older HVAC equipment using non-standard filter sizes, powder coating operations requiring maximum temperature capability, and specialty manufacturing with sustained elevated temperature exposure depend on stainless steel construction to maintain dimensional accuracy and filtration performance through years of thermal cycling between ambient and extreme operating temperatures.
Discontinued Equipment & Legacy Extreme Environment Systems
Industrial facilities maintaining older equipment in extreme environments face compounded challenges when original manufacturers discontinue filter production AND when operating environments require stainless steel’s maximum harsh environment capability rather than standard aluminum or galvanized steel construction. Vintage commercial equipment serving foundries, legacy industrial ventilation systems in chemical processing facilities with non-standard dimensions, European-manufactured extreme temperature HVAC equipment using metric sizing, and specialty extreme environment applications with custom filter requirements benefit from the HISS10’s combination of made-to-order dimensional flexibility and premium stainless steel construction. The custom manufacturing process ensures exact dimensional match to original specifications while stainless steel provides the extraordinary temperature capability and maximum corrosion resistance required by extreme operating conditions. Once you’ve specified your custom dimensions and confirmed stainless steel performance in your specific harsh environment, future reorders through your online account maintain consistent filtration capability without the perpetual frustration of searching for compatible custom-sized extreme-duty replacement filters.
Material Selection Guide
The HISS10 features premium Type 304 stainless steel construction specifically engineered for extreme temperature applications and highly corrosive environments requiring maximum harsh environment capability beyond galvanized steel’s and aluminum’s limitations. Understanding when stainless steel provides essential performance—compared to cost-effective aluminum or industrial-grade galvanized steel—ensures optimal material selection, maximum service life, and return on investment based on your specific extreme operating environment.
HIS: 304 Stainless Steel Construction (Premium Grade – Harsh Environment)
The Type 304 stainless steel construction features 24-gauge stainless steel frame with 5-ply stainless steel screen wire media and 30-gauge stainless steel face grids, delivering exceptional 900°F continuous temperature rating and maximum corrosion resistance for the most extreme and harsh environment applications. The chromium-nickel alloy composition provides unmatched resistance to corrosion from acidic vapors, alkaline atmospheres, salt spray, chemical exposure, and aggressive industrial environments while maintaining structural integrity at temperatures up to 900°F—575°F higher than galvanized steel and 575°F higher than aluminum. Choose stainless steel when your application involves extreme temperatures exceeding 325°F (foundries, commercial bakeries, industrial drying operations, forge shops), highly corrosive chemical environments with acid or alkaline vapor exposure, salt-laden coastal atmospheres requiring maximum corrosion resistance, operations requiring caustic cleaning agents that would damage alternative materials, or when maximum 5-10 year service life in extraordinarily harsh environments justifies premium investment. Stainless steel excels in foundries, commercial bakery ovens, chemical processing facilities, powder coating curing operations, industrial drying systems, pharmaceutical cleanrooms, electroplating facilities, and extreme corrosion or temperature applications where galvanized steel’s 325°F rating or zinc coating protection proves inadequate. Note that service life for stainless steel is 5-10 years—the same as galvanized steel and aluminum—with stainless steel’s advantage being its ability to achieve this service life in extremely harsh environments rather than extended longevity in standard conditions. The premium cost is justified when extreme temperature or corrosion conditions make alternative materials unsuitable.
HIG: Galvanized Steel Construction (Industrial Grade)
Galvanized steel construction with 325°F temperature rating provides enhanced corrosion resistance and elevated temperature capability at moderate cost, serving most industrial applications effectively. With hot-dip galvanized coating for exceptional rust resistance and 50°F higher temperature rating than aluminum, galvanized steel handles humid environments, moderate corrosion exposure, and temperatures up to 325°F. Consider upgrading to stainless steel (HISS10) when your application involves extreme temperatures exceeding 325°F, highly corrosive chemical environments beyond galvanized steel’s zinc coating protection, salt spray or acidic vapor exposure that would compromise zinc coating, or when caustic cleaning agents are required. For temperatures between 275-325°F and moderate corrosion environments, galvanized steel (HIGS10) provides optimal cost-effectiveness—reserve stainless steel for truly extreme applications where galvanized steel’s capabilities prove inadequate.
HIA: Aluminum Construction (Standard Grade)
Aluminum construction with 275°F temperature rating provides the most cost-effective filtration solution for standard commercial and residential HVAC applications with normal indoor temperatures and dry environments. Aluminum serves the majority of HVAC environments at lowest initial cost with excellent performance in non-extreme conditions. Consider upgrading to stainless steel (HISS10) when your application involves temperatures approaching or exceeding 275°F, highly corrosive environments, chemical vapor exposure, or when previous aluminum filters have shown rapid degradation due to environmental conditions. For extreme applications requiring maximum temperature capability or harsh environment corrosion resistance, stainless steel’s premium cost delivers necessary performance that aluminum cannot provide.
Construction Features
The HISS10 Custom 1″ Stainless Steel Washable Mesh Filter is engineered with precision manufacturing techniques and premium Type 304 stainless steel materials that ensure every custom-sized unit meets rigorous quality standards for maximum harsh environment durability, extraordinary temperature capability, and exceptional corrosion resistance. UL 900 Class 1 certification validates continuous operation capability at 900°F, while Made in USA construction guarantees dimensional accuracy and structural integrity throughout the filter’s 5-10 year service life in the most extreme industrial environments.
Type 304 Stainless Steel Frame Construction
The foundation of this custom filter begins with a precision-formed 24-gauge Type 304 stainless steel frame, featuring chromium-nickel alloy composition that provides maximum corrosion resistance and extraordinary temperature capability. Type 304 stainless steel resists corrosion from acidic environments, alkaline atmospheres, salt spray, chemical exposure, and aggressive industrial conditions that would compromise galvanized steel’s zinc coating or aluminum’s oxide layer. The 24-gauge thickness delivers excellent structural rigidity while the stainless steel composition ensures the frame maintains dimensional stability and structural integrity throughout repeated thermal cycling between ambient and extreme operating temperatures up to 900°F. Professional-grade mitered corners secured with Type 304 stainless steel pop rivets ensure the frame maintains perfect dimensional accuracy to your custom specifications throughout repeated cleaning cycles—even with aggressive caustic cleaning agents—and years of service in the most demanding harsh environment conditions. Each custom frame is manufactured to your exact height and width requirements with ±1/8″ tolerance, ensuring precise fit without gaps or binding in your HVAC system’s filter tracks while the stainless steel construction prevents the corrosion-induced dimensional changes and thermal degradation that can compromise alternative materials in extreme applications.
Premium 5-Ply Stainless Steel Media Pack
The filtration media consists of five layers of corrugated Type 304 stainless steel screen wire arranged in a precision criss-cross weave pattern specifically engineered for 1″ nominal depth applications. This all-stainless 5-ply configuration achieves 43% dust arrestance efficiency while maintaining low airflow resistance of just 0.08″ w.g. at rated airflow. The stainless steel media provides excellent particulate capture while delivering the extraordinary temperature capability and maximum corrosion resistance required for extreme and harsh environment applications. Each layer features expanded mesh construction with carefully engineered strand spacing that captures large particulates through multiple interception stages. The corrugated structure provides increased surface area within the 1″ nominal depth while the criss-cross weave pattern ensures uniform particle distribution across the entire media pack. This all-stainless engineering approach delivers effective pre-filtration performance with minimal pressure drop, protecting downstream HVAC components without overburdening system blowers—with stainless steel construction ensuring the entire filter assembly maintains structural integrity and filtration performance even when extreme operating conditions would compromise galvanized steel’s zinc coating or cause aluminum degradation.
Corner Drain System
Three strategically positioned corner drain holes facilitate rapid water evacuation following cleaning operations, with typical air-drying times of 30-90 minutes depending on ambient conditions. The open mesh construction and robust stainless steel frame design enable complete water drainage without trapped moisture in corner joints or frame channels. This drainage system prevents water pooling that could lead to odor development while the Type 304 stainless steel construction ensures the frame resists corrosion even with repeated wet-dry cycles, aggressive caustic cleaning agents, and exposure to corrosive cleaning protocols throughout the filter’s multi-year service life. The stainless steel construction naturally resists rust formation and chemical attack in all environments, maintaining structural integrity and filtration performance through thousands of operational hours at extreme temperatures and repeated cleaning cycles with aggressive agents—delivering consistent dimensional accuracy and reliable filtration in harsh environment conditions where galvanized steel’s zinc coating would be compromised or aluminum would experience severe degradation.
Stainless Steel Face Grid Protection
Both upstream and downstream faces incorporate 30-gauge Type 304 stainless steel protective grids that shield the 5-ply media layers from physical damage during handling, installation, and operation. These stainless steel face grids distribute incoming airflow uniformly across the entire filter surface, preventing concentrated jet streams that could damage the media structure while maintaining the low pressure drop characteristic of 1″ nominal depth filtration. The grid construction provides impact resistance against accidental contact during filter changeouts while the stainless steel composition ensures the face grids resist corrosion and maintain structural integrity in highly corrosive chemical atmospheres, salt-laden environments, and extreme temperature applications where alternative materials would fail. This protective layer ensures the custom-manufactured filter maintains its structural integrity and filtration performance throughout thousands of operational hours at extreme temperatures, repeated cleaning cycles with caustic agents, and continuous exposure to harsh environment conditions—with all-stainless construction delivering maximum durability in demanding industrial and commercial applications that exceed galvanized steel’s and aluminum’s capabilities.
Maintenance & Cleaning Protocol
The HISS10 Custom 1″ Stainless Steel Washable Mesh Filter requires minimal maintenance while delivering 5-10 years of reliable service in the most extreme industrial and commercial environments. Unlike disposable filters that create ongoing frustration finding compatible replacements for custom sizes, this premium stainless steel mesh filter supports repeated cleaning cycles using simple water-based methods, aggressive detergents, and even caustic cleaning agents without corrosion concerns—with Type 304 stainless steel construction ensuring maximum durability throughout years of cleaning cycles in harsh environments.
Cleaning Methods
Four effective cleaning methods accommodate different facility capabilities and contamination levels. Garden hose cleaning provides the simplest approach, using high-pressure nozzle settings to spray both sides of the 5-ply media until water runs clear—typically sufficient for most commercial and light industrial applications. Sink or tub soaking works well for moderate to heavy contamination, submerging the filter in warm soapy water for 15-30 minutes before rinsing thoroughly (stainless steel tolerates aggressive detergents, caustic cleaning agents, and corrosive cleaning solutions that would damage galvanized or aluminum construction). Commercial dishwashers offer hands-off cleaning for facilities with industrial dishwashing equipment, with stainless steel construction tolerating extreme temperatures and harsh commercial detergents without degradation. Pressure washing delivers fast results for heavy contamination typical in extreme-particulate industrial applications, using 1000-1500 PSI with warm water—stainless steel’s robust construction tolerates maximum pressure and aggressive cleaning without corrosion while maintaining structural integrity throughout repeated high-pressure wet cleaning cycles. The Type 304 stainless steel frame, media, and face grids withstand repeated washing with caustic agents, acidic cleaners, or alkaline detergents without corrosion or degradation, maintaining structural integrity throughout the filter’s service life while operating continuously at temperatures up to 900°F.
Recommended Cleaning Frequency
Cleaning intervals depend on operating environment and particulate loading rates. Light dust environments such as standard commercial applications require quarterly cleaning every three months. Moderate industrial applications including manufacturing facilities and commercial operations benefit from monthly cleaning schedules. High-particulate industrial environments with continuous dust generation may need bi-weekly to monthly cleaning to maintain optimal system performance. Visual inspection provides the most reliable cleaning indicator—schedule cleaning when the 5-ply screen wire media appears visibly loaded with dust or when system airflow seems reduced. Monitor pressure drop across the filter if instrumentation is available, cleaning when resistance reaches 0.50″ w.g. to maintain energy-efficient system operation. In harsh corrosive environments or applications involving chemical exposure, the Type 304 stainless steel construction maintains its integrity indefinitely—properly maintained stainless steel filters show no corrosion throughout their 5-10 year service life even in the most aggressive chemical and temperature environments.
Handling Considerations for Stainless Steel Construction
Stainless steel filters provide maximum durability with heavier weight compared to galvanized steel and aluminum construction, tolerating aggressive handling, caustic cleaning agents, and extreme pressure washing while still benefiting from proper support during maintenance. Support larger custom sizes from underneath during cleaning and installation to prevent frame stress. The 24-gauge stainless steel frame construction provides exceptional structural rigidity, though heavier custom sizes may require two-person handling for safe installation and removal. The Type 304 stainless steel construction tolerates repeated wet-dry cycles, caustic cleaning agents, acidic or alkaline cleaners, and aggressive mechanical cleaning without degradation—maintaining corrosion resistance, structural integrity, and dimensional stability throughout years of service in the most demanding harsh environment applications. Stainless steel construction resists damage from all standard cleaning protocols, making it the optimal choice when aggressive cleaning procedures are required or when chemical exposure demands maximum material durability.
Installation
Installing the HISS10 Custom 1″ Stainless Steel Washable Mesh Filter follows the same straightforward procedures as standard filters, with attention to proper orientation and secure seating to ensure optimal performance from your custom-manufactured premium-grade harsh environment filtration solution.
Pre-Installation Verification
Before installing your custom stainless steel filter, verify the dimensions match your original specifications and that your HVAC system is completely shut down with power disconnected. Inspect the filter housing interior for accumulated dust, debris, or damage that could compromise the seal. The custom-manufactured filter should fit your housing precisely with minimal clearance—if excessive gaps exist, verify you’re installing in the correct location and orientation. Check the condition of existing gaskets or sealing surfaces, replacing worn gaskets before installing your new permanent filter. Clean the filter housing interior thoroughly with a vacuum or damp cloth to ensure optimal sealing surfaces. Locate the airflow direction arrow marked on your new custom filter frame, ensuring you understand proper orientation before installation. Note the stainless steel construction for documentation in your maintenance records, particularly in extreme environment applications where tracking filter material specifications supports compliance and quality management protocols and where the 900°F temperature rating and maximum corrosion resistance are critical performance requirements.
Installation Steps
With the HVAC system powered off and locked out, open the filter access door or remove the access panel. Carefully remove any existing filter, noting its orientation and airflow direction. Inspect your new HISS10 custom stainless steel filter and locate the airflow direction arrow clearly marked on the frame. The 1″ nominal (7/8″ actual) depth provides comfortable handling, though the stainless steel construction creates heavier weight than galvanized steel or aluminum—larger custom sizes may benefit from two-person installation. Insert the filter into the housing with the airflow arrow pointing in the correct direction of air movement through your system. Press the filter firmly into place, ensuring all edges seat properly against the gasket or housing walls without forcing. The robust 24-gauge stainless steel frame construction prevents flexing during installation while the custom dimensions create proper fit without excessive gaps around the perimeter. Secure the access door or panel, restore power, and restart system operation.
Post-Installation Verification
After system restart, listen carefully for any unusual sounds such as air whistling or rattling that might indicate improper seating. Verify proper airflow by checking that air velocity at supply registers matches expected performance levels. The low pressure drop of the 1″ nominal filter means system performance should match or exceed previous levels with superior harsh environment filtration capability. Document the installation date, custom dimensions, and stainless steel construction specification in your maintenance records for future reordering through your online account. The 43% dust arrestance efficiency begins immediately protecting downstream HVAC components from large particulates and debris while the 900°F temperature rating and maximum corrosion resistance ensure filtration performance in extreme environments. Establish a regular inspection schedule based on your specific environmental conditions to monitor dust accumulation and maintain optimal system performance throughout the filter’s 5-10 year service life. In extreme temperature or highly corrosive industrial environments, the Type 304 stainless steel construction provides peace of mind that the filter will maintain structural integrity, dimensional accuracy, and filtration performance throughout years of demanding service in conditions where galvanized steel’s zinc coating would be compromised and aluminum would experience premature failure.
Complementary Products
The HISS10 Custom 1″ Stainless Steel Washable Mesh Filter excels as a pre-filtration stage in extreme environments, but complete HVAC protection in multi-stage harsh environment systems may require complementary secondary filtration products. By combining this custom stainless steel mesh pre-filter with specialized secondary filters, you achieve optimal air quality while protecting expensive downstream filtration equipment in the most demanding industrial extreme temperature and corrosive environments.
The 43% dust arrestance efficiency of this custom 1″ stainless steel mesh pre-filter makes it the ideal first stage for extreme environment filtration systems requiring custom dimensions where standard filters cannot accommodate unique equipment specifications and where operating conditions demand stainless steel’s maximum harsh environment capability.
Custom Secondary Filtration (Stainless Steel)
For systems requiring secondary filtration in custom dimensions with consistent stainless steel construction:
• Custom 2″ Stainless Steel Secondary Filter (HISS20) – Follow your custom 1″ stainless pre-filter with custom 2″ stainless secondary filtration for enhanced particle capture and extended cleaning intervals while maintaining consistent extreme temperature capability and maximum corrosion resistance.
• Custom 4″ Stainless Steel Secondary Filter (HISS40) – 4-inch depth custom stainless filter provides maximum dust-holding capacity after 1″ pre-filtration stage in the most demanding extreme environment applications.
Alternative Material Secondary Filters (Custom Dimensions)
For multi-stage systems where pre-filter faces harsher conditions than secondary stages:
• Custom 2″ Galvanized Steel Filter (HIGS20) – Industrial-grade galvanized secondary stage for applications where pre-filter requires stainless steel’s extreme temperature capability but downstream positions operate within galvanized steel’s 325°F rating.
• Custom 2″ Aluminum Filter (HIAS20) – Cost-effective aluminum secondary stage for applications where pre-filter faces extreme conditions but downstream filtration operates in standard temperature ranges.
Standard Stainless Steel Filters (If Dimensions Match)
If your secondary stage uses standard dimensions:
• HIS201620 – 16x20x2 Stainless Steel Filter – Standard 2-inch stainless steel filter for enhanced secondary filtration in extreme temperature applications.
• HIS201224 – 12x24x2 Stainless Steel Filter – Stock 2-inch stainless steel secondary filter for immediate availability with 900°F rating.
• HIS401620 – 16x20x4 Stainless Steel Filter – Deep 4-inch stainless steel filtration for maximum secondary stage dust-holding capacity in extreme environments.
Frequently Asked Questions
When should I choose stainless steel over galvanized steel or aluminum?
Choose stainless steel (HISS10 at 900°F) when your application involves extreme temperatures exceeding 325°F (foundries, commercial bakeries, industrial drying operations), highly corrosive chemical environments beyond galvanized steel’s zinc coating protection, salt-laden coastal atmospheres requiring maximum corrosion resistance, or operations requiring caustic cleaning agents. Stainless steel provides 575°F higher temperature rating than galvanized steel (325°F) and 625°F higher than aluminum (275°F), plus unmatched corrosion resistance to chemical attack. For temperatures below 325°F with moderate corrosion, galvanized steel (HIGS10) provides better cost-effectiveness. For standard environments below 275°F, aluminum (HIAS10) offers lowest cost. The premium investment in stainless steel is justified when extreme conditions make alternative materials unsuitable.
What environments require stainless steel’s 900°F rating?
The 900°F continuous temperature rating serves foundry ventilation near metal melting operations, commercial bakery oven exhaust systems, forge shop ventilation, industrial drying operations with sustained elevated temperatures, powder coating curing ovens, high-temperature manufacturing processes, and any application where ambient temperatures approach or exceed galvanized steel’s 325°F limit or aluminum’s 275°F limit. If your HVAC system operates in proximity to heat-generating equipment that creates sustained temperatures above 325°F, stainless steel construction is essential to prevent structural degradation, warping, or premature failure that would occur with alternative materials.
Does stainless steel construction affect filtration efficiency or cleaning?
No, material selection does not affect filtration performance. The HISS10 stainless steel filter provides identical 43% dust arrestance efficiency and 68 g/sq ft dust-holding capacity as galvanized steel or aluminum construction. The 5-ply media configuration delivers the same particle capture performance regardless of frame material. However, stainless steel does affect cleaning tolerance—the Type 304 construction withstands caustic cleaning agents, acidic cleaners, and aggressive detergents that would damage galvanized steel’s zinc coating or aluminum. This makes stainless steel ideal when specialized cleaning protocols are required or when chemical exposure during operation demands maximum material durability.
Is stainless steel construction food-safe for bakeries and food processing?
Yes, Type 304 stainless steel is food-grade material widely used in commercial food processing and bakery equipment. The HISS10’s all-stainless construction meets food industry standards for materials in food production environments. The non-porous surface resists bacterial growth while tolerating aggressive food-safe cleaning protocols and sanitizers required in commercial food operations. Commercial bakeries benefit from both the food-grade material properties and the exceptional 900°F temperature rating required near commercial ovens, making stainless steel the optimal choice for bakery ventilation systems where food safety standards and extreme temperature capability intersect.
Can stainless steel filters withstand caustic or acidic cleaning agents?
Yes, Type 304 stainless steel construction resists corrosion from caustic cleaning agents, acidic cleaners, alkaline detergents, and aggressive industrial cleaning solutions that would damage galvanized steel’s zinc coating or aluminum. This makes the HISS10 ideal for applications requiring specialized cleaning protocols—including chemical processing facilities that must decontaminate filters exposed to process vapors, pharmaceutical cleanrooms requiring validated cleaning procedures, or any operation where aggressive cleaning agents are necessary. The all-stainless construction maintains structural integrity and dimensional accuracy through repeated cleaning cycles with harsh chemicals that would compromise alternative materials.
Does stainless steel last longer than galvanized steel or aluminum?
Service life for properly maintained washable mesh filters is 5-10 years regardless of material—aluminum, galvanized steel, and stainless steel all achieve this lifespan with proper maintenance. The difference is WHERE each material achieves this service life. Aluminum achieves 5-10 years in standard environments below 275°F with low corrosion. Galvanized steel achieves 5-10 years in industrial environments up to 325°F with moderate corrosion. Stainless steel achieves 5-10 years in EXTREME environments up to 900°F with maximum corrosion exposure. Stainless steel’s advantage is its ability to deliver full service life in harsh environments where alternative materials would fail prematurely—not extended longevity in standard conditions. Choose stainless steel based on your extreme operating environment, not for longer service life.
Can I order the same custom dimensions in aluminum, galvanized, or stainless steel?
Yes, absolutely. Once you’ve specified your custom dimensions for the HISS10 stainless steel filter, you can order the same size in galvanized steel (HIGS10) for industrial-grade applications or aluminum (HIAS10) for cost-effective standard applications. Many facility managers maintain inventory in multiple materials for different zones—aluminum for standard areas, galvanized steel for industrial zones with temperatures up to 325°F, stainless steel for extreme temperature or highly corrosive areas. Your custom dimensions are saved in your account for easy reordering in the same or different materials as needs change.
How long does custom stainless steel filter manufacturing take?
Custom stainless steel filter manufacturing typically requires 5-10 business days from order confirmation to shipment, though production schedules may vary based on current order volume. Stainless steel production may add 1-2 days to lead time compared to aluminum or galvanized steel due to specialized stainless steel processing. Rush production is available for critical applications. We recommend ordering before your existing filter reaches end-of-service to ensure continuous filtration coverage, particularly in extreme environment applications where extended lead times might otherwise create operational challenges in harsh condition environments.
Why Choose the HISS10 Custom 1″ Stainless Steel Washable Mesh Filter?
Choosing the HISS10 Custom 1″ Stainless Steel Washable Mesh Filter eliminates the frustration and expense of searching for compatible replacement filters for HVAC systems with discontinued or non-standard dimensions while providing maximum harsh environment capability, exceptional corrosion resistance, and extraordinary 900°F temperature capability that galvanized steel and aluminum construction cannot match. Whether you’re maintaining foundry ventilation systems operating above 325°F, supporting chemical processing facilities with highly corrosive vapor atmospheres, servicing commercial bakery ovens requiring continuous extreme temperature capability, or managing industrial drying operations where standard materials degrade prematurely, this made-to-order premium stainless steel solution provides permanent filtration precisely matched to your unique dimensional requirements and extreme operating conditions. The custom manufacturing process ensures perfect dimensional fit while Type 304 stainless steel construction ensures optimal performance and maximum service life in harsh environments where alternative materials prove inadequate.
Built to the same rigorous quality standards as our stock HIS Series products, this custom filter features precision-engineered 5-ply all-stainless media construction and UL 900 Class 1 certification with exceptional 900°F continuous temperature rating—575°F higher than galvanized steel’s 325°F limitation and 625°F higher than aluminum’s 275°F constraint. The industry-standard 1″ nominal (7/8″ actual) depth profile fits the vast majority of HVAC filter tracks while providing optimal balance of dust-holding capacity and airflow resistance. Made in USA with premium 24-gauge Type 304 stainless steel frames, all-stainless media, and 30-gauge stainless steel face grids, each custom filter is manufactured to your exact specifications with ±1/8″ tolerance, ensuring precise fit and optimal performance throughout its 5-10 year service life in the most extreme industrial and commercial applications.
The permanent washable construction delivers exceptional long-term value compared to disposable alternatives—especially critical for custom sizes where finding compatible replacements creates ongoing frustration and expense and where stainless steel’s maximum harsh environment capability extends service life in extreme conditions where galvanized steel’s zinc coating would be compromised and aluminum would experience rapid failure. Once you’ve placed your initial custom order, reordering identical stainless steel filters is effortless through your online account, eliminating the need to re-measure or re-specify dimensions for future purchases. The 43% dust arrestance efficiency protects downstream HVAC components while the low 0.08″ pressure drop maintains optimal system efficiency. Simple water-based cleaning every few months—or aggressive caustic cleaning when required—restores peak performance, with Type 304 stainless steel construction supporting repeated cleaning cycles with harsh chemicals throughout the filter’s multi-year service life without corrosion or degradation.
Facility managers, property owners, HVAC contractors, and industrial maintenance professionals choose the HISS10 when standard filters cannot solve their combined dimensional and extreme environment filtration challenges and when operating conditions demand maximum harsh environment capability exceeding galvanized steel’s and aluminum’s limitations. From maintaining vintage extreme temperature equipment with discontinued filter dimensions to supporting highly corrosive chemical processing environments requiring exceptional corrosion resistance and 900°F temperature capability, this custom stainless steel mesh filter provides the permanent solution that eliminates filter procurement frustration while delivering premium-grade filtration performance matched to your exact dimensional and extreme environmental requirements. Invest in a custom-manufactured filter that fits your system perfectly, uses premium Type 304 stainless steel materials engineered for the most demanding harsh environment conditions, provides up to a decade of reliable service in extreme applications, and ensures you’ll never struggle to find compatible replacements again. Order your custom HISS10 today and experience the confidence that comes from having a permanent filtration solution precisely matched to every aspect of your unique HVAC system requirements—with premium stainless steel construction delivering the maximum harsh environment capability, extraordinary temperature rating, and exceptional corrosion resistance your extreme application demands.
Additional information
| Weight | 48.0 oz |
|---|---|
| Frame Material | 304 Stainless Steel |
| GTIN | 00840373527373 |
| MPN | HISS10 |
Custom Mesh Filter, Galvanized Steel, 2 Inch Thick
As low as $0.16 per sq inch
Please provide actual L x W measurements down to the 1/16th inch. Example: “15.25 x 24.1875”. Custom size filters are not returnable so please double check before ordering.
| 1/16 = .0625 | 9/16″ = .5625 |
| 1/8 = .125 | 5/8″ = .625 |
| 3/16 = .1875 | 11/16″ = .6875 |
| 1/4 = .25 | 3/4″ = .75 |
| 5/16 = .3125 | 13/16″ = .8125 |
| 3/8 = .375 | 7/8″ = .875 |
| 7/16 = .4375 | 15/16″ = .9375 |
| 1/2 = .5 | 1″ = 1 |
Description
Product Overview
The HIGS20 Custom 2″ Galvanized Steel Washable Mesh Filter delivers industrial-grade filtration performance for HVAC systems requiring enhanced durability, superior corrosion resistance, elevated temperature capability, and extended dust-holding capacity in custom dimensions that off-the-shelf products cannot provide. This made-to-order 2″ nominal depth (1-3/4″ actual) galvanized steel mesh filter combines 24-gauge hot-dip galvanized steel frame construction with robust 7-ply corrugated criss-cross screen wire media, providing 325°F continuous temperature capability and exceptional corrosion resistance for humid industrial environments, commercial laundries, food processing facilities, manufacturing operations, and applications where standard aluminum construction proves inadequate. Built to UL 900 Class 1 standards with custom manufacturing to your exact dimensional specifications, this galvanized steel filter ensures reliable pre-filtration performance tailored precisely to your unique HVAC system needs while delivering 97 grams per square foot dust-holding capacity—42% more than 1″ filters—extending cleaning intervals and reducing maintenance frequency in demanding industrial conditions.
Engineered with precision-formed 24-gauge galvanized steel frames paired with specialized 7-ply corrugated aluminum screen wire media and 30-gauge galvanized steel face grids, the HIGS20 delivers 43% dust arrestance efficiency in the industry-standard 2″ nominal depth profile. This industrial-grade configuration serves environments requiring enhanced moisture resistance, elevated temperature handling, and extended cleaning intervals—from commercial kitchens operating at elevated ambient temperatures with grease-laden airstreams to manufacturing facilities with high humidity levels and heavy particulate loading where aluminum filters experience premature corrosion or require excessive cleaning frequency. Custom-manufactured to your exact specifications in the USA, each filter ships ready to install with no modifications required, providing permanent filtration for discontinued equipment, non-standard installations, and harsh industrial applications demanding materials that maintain structural integrity and extended service intervals beyond aluminum’s capabilities.
Unlike disposable filters requiring constant replacement—especially problematic for custom sizes with discontinued or non-standard dimensions—this custom galvanized steel washable mesh filter delivers 5-10 years of continuous service with proper maintenance protocols. The robust hot-dip galvanized construction features precision-mitered corners secured with galvanized pop rivets and 30-gauge galvanized steel face grids ensuring structural integrity through repeated cleaning cycles using standard water-based methods. The 7-ply media configuration with 97 g/sq ft dust-holding capacity extends cleaning intervals significantly compared to 1″ depth filters, reducing maintenance labor costs in applications where filter accessibility challenges make frequent service expensive. Three strategically placed corner drain holes facilitate complete water removal after washing, preventing moisture retention and accelerating return-to-service time. Once you’ve placed your initial custom order, reordering identical replacements is effortless through your online account, ensuring you’ll never struggle to find the right filter size again while maintaining the enhanced durability, temperature capability, and extended service intervals that galvanized steel provides.
Facility managers, property owners, and HVAC contractors working with industrial environments, elevated temperature applications, humid conditions, heavy particulate loading, or equipment requiring enhanced corrosion resistance rely on custom galvanized steel washable mesh filters to solve filtration challenges where aluminum construction falls short. Whether you’re maintaining commercial kitchen ventilation systems with sustained elevated temperatures and moisture exposure, supporting manufacturing facilities with high humidity and continuous dust generation, servicing food processing plants requiring frequent washdown environments with extended cleaning intervals, or managing commercial laundries operating at sustained elevated temperatures with heavy lint loading, the HIGS20 provides a permanent solution manufactured to your exact specifications. With 325°F continuous temperature rating, superior corrosion resistance compared to aluminum, 97 g/sq ft dust-holding capacity for extended cleaning intervals, low initial airflow resistance, and the ability to maintain peak performance through repeated cleaning cycles, this custom galvanized steel washable mesh filter delivers measurable ROI through eliminated filter replacement costs, extended service life in demanding conditions, reduced maintenance frequency, and the peace of mind that comes from having a reliable long-term filtration solution precisely matched to your system dimensions and operating environment.
Key Benefits of the HIGS20 Custom 2″ Galvanized Steel Washable Mesh Filter
- Industrial-Grade Galvanized Steel Construction: 24-gauge hot-dip galvanized steel frame with 30-gauge galvanized steel face grids provides enhanced corrosion resistance and structural integrity in humid, corrosive, or elevated temperature environments where aluminum construction degrades prematurely.
- 325°F Continuous Temperature Rating: 50°F higher operating temperature than aluminum construction serves commercial kitchens, manufacturing facilities, and industrial applications with sustained elevated ambient temperatures that exceed aluminum’s 275°F limitation.
- Superior Dust-Holding Capacity: 7-ply media construction delivers 97 grams per square foot dust-holding capacity—42% more than 1″ filters—extending cleaning intervals significantly and reducing maintenance frequency in high-particulate industrial environments.
- Custom Sizing for Any HVAC System: Made-to-order manufacturing accommodates any height and width combination, solving filtration challenges for discontinued equipment, industrial systems, and non-standard installations where off-the-shelf galvanized filters don’t fit.
- Enhanced Moisture & Humidity Resistance: Hot-dip galvanized coating provides exceptional rust resistance in humid environments, frequent washdown operations, and moisture-rich atmospheres where aluminum oxidation becomes problematic.
- Effortless Reordering: Once you’ve placed your initial custom order, reordering identical galvanized steel filters is simple through your online account—no need to re-measure or re-specify dimensions for future purchases.
Technical Specifications
The HIGS20 Custom 2″ Galvanized Steel Washable Mesh Filter represents precision-engineered filtration technology manufactured to your exact dimensional specifications with industrial-grade galvanized steel construction and enhanced dust-holding capacity. This industry-standard 2″ nominal depth (1-3/4″ actual) galvanized mesh pre-filter delivers exceptional performance validated through rigorous UL 900 Class 1 testing, ensuring reliable operation in continuous high-temperature and corrosive environments up to 325°F. Every custom filter is built with the same industrial-grade construction standards as our stock HIG Series products, providing the enhanced durability, corrosion resistance, and extended cleaning intervals you expect from hot-dip galvanized steel construction with dimensions tailored precisely to your unique HVAC system requirements.
Manufactured in the USA using premium 24-gauge galvanized steel framing paired with 7-ply corrugated criss-cross aluminum screen wire media and 30-gauge galvanized steel face grids, this custom washable mesh filter meets the stringent requirements of industrial and commercial HVAC applications requiring non-standard filter dimensions with enhanced environmental resistance and superior dust-holding capacity. The 2″ nominal (1-3/4″ actual) depth profile ensures compatibility with the vast majority of HVAC filter tracks designed for 2-inch filters while the 43% dust arrestance efficiency protects downstream equipment from premature loading. With 97 grams per square foot dust-holding capacity—42% higher than 1″ depth filters—this custom galvanized steel filter extends cleaning intervals substantially and reduces maintenance frequency in applications where finding replacement filters has historically been challenging and where material durability and extended service intervals directly impact operational costs.
| Specifications: | Details: |
|---|---|
| Model Number | HIGS20 (Custom 2″ Galvanized Steel) |
| Filter Depth | 2″ nominal (1-3/4″ actual depth) |
| Height & Width | Custom dimensions manufactured to your exact specifications |
| Dimensional Tolerance | ±1/8″ on height and width, ±1/16″ on depth |
| Frame Material | 24-gauge hot-dip galvanized steel |
| Filter Media | 7-ply corrugated criss-cross aluminum screen wire mesh |
| Face Grid Material | 30-gauge galvanized steel |
| Frame Construction | Precision-mitered corners, galvanized pop rivets |
| Drainage | 3 corner drain holes for complete water removal after washing |
| Maximum Operating Temperature | 325°F continuous (UL 900 Class 1 certified) |
| Dust Arrestance Efficiency | 43% average at rated airflow (350 FPM) |
| Dust Holding Capacity | 97 grams per square foot (42% more than 1″ filters) |
| Rated Airflow | 350 FPM (feet per minute) |
| Recommended Airflow Range | 300-500 FPM face velocity |
| Initial Pressure Drop | 0.10″ w.g. @ 350 FPM (clean filter) |
| Recommended Final Resistance | 0.50″ w.g. (water gauge) before cleaning |
| Weight | Varies by custom dimensions (heavier than aluminum, lighter than stainless) |
| Washability | Repeated cleaning cycles with water-based methods, detergents, or pressure washers |
| Service Life | 5-10 years with proper maintenance protocols |
| Compliance & Certifications | UL 900 Class 1, ASTM E 2931 (washable filter standard) |
| Country of Origin | Made in USA |
Industrial & Specialized Applications
The HIGS20 Custom 2″ Galvanized Steel Washable Mesh Filter solves critical filtration challenges across industrial and commercial applications where enhanced corrosion resistance, elevated temperature capability, extended dust-holding capacity, and structural durability exceed aluminum’s limitations while custom dimensions accommodate unique HVAC equipment requirements. From humid manufacturing environments with heavy particulate loading to commercial kitchens operating at sustained elevated temperatures with extended cleaning interval requirements, this galvanized steel solution with 7-ply media construction ensures reliable pre-filtration when standard materials and standard sizes cannot meet your system’s combined dimensional, environmental, and maintenance demands.
Commercial Kitchen & Food Service Equipment
Commercial kitchens, restaurants, and food processing facilities operate HVAC systems exposed to elevated ambient temperatures, grease-laden airstreams, high humidity, and frequent washdown protocols that accelerate aluminum corrosion while heavy particulate loading demands extended cleaning intervals. The HIGS20’s 325°F continuous temperature rating and superior galvanized steel corrosion resistance combined with 97 g/sq ft dust-holding capacity serve ventilation systems for commercial ovens, dishwasher hood exhaust, prep area ventilation, and walk-in cooler/freezer condensing units where temperatures regularly exceed aluminum’s 275°F capability, where moisture exposure demands enhanced rust protection, and where filter accessibility challenges make frequent 1″ filter cleaning impractical. Restaurant chains maintaining older HVAC equipment with discontinued filter dimensions requiring extended service intervals, institutional kitchens in schools and hospitals with non-standard ventilation configurations and limited maintenance access, and food processing plants requiring custom-sized pre-filtration for specialized equipment with heavy particulate loading depend on galvanized steel construction with 7-ply media to maintain filtration performance throughout years of demanding service while minimizing cleaning frequency. The permanent washable construction means once you’ve established your custom dimensions and experienced galvanized steel’s superior durability combined with extended cleaning intervals in your specific application, reordering identical replacements through your online account ensures consistent filtration performance without the frustration of searching for compatible custom-sized alternatives.
Manufacturing & Industrial Facilities
Industrial manufacturing environments—including textile mills, printing operations, chemical processing plants, and general manufacturing facilities—subject HVAC filtration systems to elevated temperatures, high humidity levels, chemical vapor exposure, and heavy continuous particulate loading that compromise aluminum filter longevity while demanding extended cleaning intervals to reduce maintenance labor costs. The HIGS20’s hot-dip galvanized steel construction provides exceptional corrosion resistance in humid industrial atmospheres while the 325°F temperature rating protects against heat degradation and the 97 g/sq ft dust-holding capacity extends cleaning intervals substantially compared to thinner filters. Plastics manufacturing facilities with thermoforming operations generating sustained elevated temperatures and heavy airborne particulate, commercial laundries operating with continuous steam exposure and lint loading requiring extended service intervals, printing plants with solvent vapor atmospheres and paper dust accumulation, and automotive shops with paint booth ventilation systems requiring enhanced cleaning interval extension rely on galvanized steel filters with 7-ply media when equipment dimensions require custom manufacturing and when operating conditions demand materials and dust-holding capacity exceeding aluminum’s environmental and maintenance limitations. The 5-10 year service life with proper maintenance delivers exceptional ROI in industrial applications where filter accessibility challenges make frequent replacements costly and where galvanized steel’s enhanced durability combined with extended cleaning intervals directly reduces maintenance labor and system downtime.
Humid & Moisture-Rich Environments with Heavy Particulate
Applications involving sustained high humidity, frequent condensation, heavy dust loading, or regular washdown procedures benefit from galvanized steel’s superior rust resistance combined with 7-ply media’s extended cleaning intervals compared to aluminum construction with thinner media packs. Indoor swimming pool dehumidification systems with lint and debris accumulation, greenhouse climate control equipment with pollen and organic matter loading, car wash facility ventilation with moisture exposure and airborne contamination, commercial dishwashing hood exhaust with grease and steam, and coastal facilities exposed to salt-laden air with industrial dust experience accelerated aluminum oxidation that galvanized steel’s protective zinc coating effectively prevents while 97 g/sq ft capacity extends service intervals. The HIGS20 serves these moisture-rich applications with heavy particulate loading with custom dimensions matching discontinued equipment specifications while providing corrosion resistance that extends service life significantly beyond aluminum alternatives and dust-holding capacity that reduces cleaning frequency substantially. Facility managers maintaining aquatic centers with older HVAC systems using non-standard filter sizes and heavy lint loading, greenhouse operators requiring custom filtration for European-manufactured climate control equipment with pollen accumulation, and car wash operations supporting legacy ventilation systems with moisture and contamination depend on galvanized steel construction with 7-ply media to maintain structural integrity and acceptable cleaning intervals through years of moisture exposure and particulate challenge. The washable design means repeated cleaning cycles—even with aggressive detergents required in these environments—don’t compromise the galvanized coating’s protective properties, ensuring the filter maintains both dimensional accuracy and corrosion resistance throughout its service life while the enhanced dust-holding capacity keeps maintenance intervals manageable.
Discontinued Equipment & Legacy Industrial Systems
Industrial facilities maintaining older equipment face compounded challenges when original manufacturers discontinue filter production AND when operating environments require galvanized steel’s enhanced durability rather than standard aluminum construction AND when maintenance access limitations demand extended cleaning intervals. Vintage commercial rooftop units serving manufacturing facilities with heavy dust loading, legacy industrial ventilation systems with non-standard dimensions and limited maintenance access, European-manufactured industrial HVAC equipment using metric sizing with elevated temperature exposure, and specialty industrial applications with custom filter requirements and heavy particulate challenge benefit from the HIGS20’s combination of made-to-order dimensional flexibility, industrial-grade galvanized steel construction, and 7-ply media for extended service intervals. The custom manufacturing process ensures exact dimensional match to original specifications while galvanized steel provides the corrosion resistance and temperature capability required by industrial operating conditions and the 97 g/sq ft dust-holding capacity reduces maintenance frequency to manageable levels. Once you’ve specified your custom dimensions and confirmed galvanized steel performance with extended cleaning intervals in your specific environment, future reorders through your online account maintain consistent filtration capability without the perpetual frustration of searching for compatible custom-sized industrial-grade replacement filters with adequate dust-holding capacity.
Material Selection Guide
The HIGS20 features industrial-grade galvanized steel construction with 7-ply media specifically engineered for applications requiring enhanced corrosion resistance, elevated temperature capability, and extended dust-holding capacity beyond aluminum’s limitations. Understanding when galvanized steel with 2″ depth provides optimal value—compared to cost-effective aluminum or premium stainless steel, and compared to thinner 1″ depth filters—ensures maximum service life, performance, cleaning interval extension, and return on investment based on your specific operating environment and maintenance requirements.
HIG: Galvanized Steel Construction (Industrial Grade – 2″ Depth)
The galvanized steel construction features 24-gauge hot-dip galvanized steel frame construction with 7-ply aluminum screen wire media and 30-gauge galvanized steel face grids, delivering enhanced corrosion resistance, elevated 325°F temperature capability, and 97 g/sq ft dust-holding capacity at moderate cost increase over aluminum. The protective zinc coating applied through hot-dip galvanizing process provides exceptional rust resistance in humid environments, moisture-rich atmospheres, and applications involving frequent washdown or cleaning protocols, while the 7-ply media configuration extends cleaning intervals by 42% compared to 5-ply 1″ filters. Choose galvanized steel with 2″ depth when your application involves moderately elevated temperatures (275-325°F), humid environments requiring enhanced rust resistance, industrial settings where aluminum might corrode prematurely OR where heavy particulate loading demands extended cleaning intervals to reduce maintenance labor costs, or when the 50°F higher temperature rating combined with superior dust-holding capacity provides necessary operational advantages over aluminum construction. Galvanized filters with 2″ depth excel in commercial laundries with heavy lint loading, printing facilities with continuous paper dust, food processing plants with grease and organic matter accumulation, humid industrial environments with sustained particulate challenge, manufacturing operations requiring extended maintenance intervals, commercial kitchens with elevated temperatures and heavy loading, and applications where aluminum’s environmental limitations OR inadequate dust-holding capacity compromise service life or create excessive maintenance frequency. The 5-10 year service life matches aluminum and stainless steel duration but delivers this longevity in significantly more demanding conditions while the enhanced dust-holding capacity maintains manageable cleaning intervals—making galvanized steel with 2″ depth the optimal value choice for harsh environments with heavy particulate loading where aluminum fails prematurely or requires excessive maintenance.
HIA: Aluminum Construction (Standard Grade – 2″ Depth)
Aluminum construction with .030″ thick aluminum alloy frames and 7-ply media provides cost-effective filtration solution for standard commercial and residential HVAC applications with normal indoor temperatures, dry environments, and moderate particulate loading. With 275°F continuous temperature rating and excellent corrosion resistance in non-humid conditions, aluminum with 97 g/sq ft capacity serves many HVAC environments at lowest initial cost. Consider upgrading to galvanized steel (HIGS20) when your application involves temperatures approaching or exceeding 275°F, sustained high humidity levels, frequent moisture exposure, heavy continuous particulate loading requiring extended cleaning intervals, or when premature aluminum corrosion has shortened filter service life in your specific environment. The moderate cost increase for galvanized construction delivers substantial service life extension in demanding conditions and extended cleaning intervals in high-particulate applications—providing better long-term value than repeatedly replacing corroded aluminum filters or performing excessive cleaning cycles on aluminum filters with adequate depth but insufficient environmental protection.
HIS: 304 Stainless Steel Construction (Premium Grade – 2″ Depth)
304 stainless steel construction with 24-gauge stainless steel frames, 7-ply stainless media, and all-stainless face grids provides maximum corrosion resistance and exceptional 900°F continuous temperature rating for the most extreme applications. Choose stainless steel over galvanized when your application involves extreme temperatures exceeding 325°F (foundries, commercial bakeries, industrial drying operations), highly corrosive chemical environments beyond galvanized steel’s capabilities, or when maximum service life in extraordinarily harsh conditions justifies premium initial investment. For most industrial applications with elevated temperatures (275-325°F), humid or corrosive conditions, and heavy particulate loading, galvanized steel (HIGS20) with 7-ply media provides optimal balance of enhanced durability, extended cleaning intervals, and cost-effectiveness—reserving stainless steel for truly extreme environments where galvanized steel’s 325°F rating or corrosion resistance proves inadequate. Note that service life for stainless steel is 5-10 years—the same as galvanized steel and aluminum—with stainless steel’s advantage being its ability to achieve this service life in extremely harsh environments rather than extended longevity in standard conditions. The 97 g/sq ft dust-holding capacity is identical across all three materials with 2″ depth.
1″ Depth vs. 2″ Depth Comparison
When deciding between HIGS10 (1″ nominal depth, 5-ply, 68 g/sq ft) and HIGS20 (2″ nominal depth, 7-ply, 97 g/sq ft), consider both space constraints and maintenance interval requirements. Choose 1″ depth (HIGS10) when filter housing depth is limited to 1″ nominal or when moderate dust loading allows acceptable cleaning frequency with 68 g/sq ft capacity. Choose 2″ depth (HIGS20) when filter housing accommodates 2″ nominal depth AND when heavy particulate loading, limited maintenance access, or labor cost considerations justify the extended cleaning intervals provided by 42% higher dust-holding capacity. In applications where both depths physically fit, the 2″ galvanized filter typically provides better long-term value in industrial environments with heavy dust loading by substantially reducing maintenance frequency—though initial cost is moderately higher. Both depths provide identical 325°F temperature rating, corrosion resistance, and 5-10 year service life with proper maintenance.
Construction Features
The HIGS20 Custom 2″ Galvanized Steel Washable Mesh Filter is engineered with precision manufacturing techniques, industrial-grade materials, and enhanced media construction that ensure every custom-sized unit meets rigorous quality standards for enhanced durability, corrosion resistance, and extended cleaning intervals. UL 900 Class 1 certification validates continuous operation capability at 325°F, while Made in USA construction guarantees dimensional accuracy and structural integrity throughout the filter’s 5-10 year service life in demanding industrial environments with heavy particulate loading.
Hot-Dip Galvanized Steel Frame Construction
The foundation of this custom filter begins with a precision-formed 24-gauge steel frame subjected to hot-dip galvanizing process, where the steel is immersed in molten zinc to create a metallurgically bonded protective coating. This galvanizing process provides superior corrosion resistance compared to aluminum’s natural oxide layer, preventing rust formation in humid environments, moisture-rich atmospheres, and applications involving frequent wet cleaning cycles. The 24-gauge thickness delivers excellent structural rigidity while the hot-dip zinc coating ensures the frame maintains dimensional stability and corrosion resistance throughout repeated thermal cycling between ambient and elevated operating temperatures up to 325°F. The 2″ nominal (1-3/4″ actual) depth provides increased frame depth compared to 1″ filters, accommodating the robust 7-ply media pack while maintaining proper airflow transition. Professional-grade mitered corners secured with galvanized pop rivets ensure the frame maintains perfect dimensional accuracy to your custom specifications throughout repeated cleaning cycles and years of service in demanding conditions with heavy particulate loading. Each custom frame is manufactured to your exact height and width requirements with ±1/8″ tolerance, ensuring precise fit without gaps or binding in your HVAC system’s filter tracks while the galvanized construction prevents the corrosion-induced dimensional changes that can compromise aluminum filter fit over time.
Enhanced 7-Ply Media Pack
The filtration media consists of seven layers of corrugated aluminum screen wire arranged in a precision criss-cross weave pattern specifically engineered for 2″ nominal depth applications. This 7-ply configuration achieves 43% dust arrestance efficiency while delivering 97 grams per square foot dust-holding capacity—42% more than 5-ply 1″ filters—substantially extending cleaning intervals and reducing maintenance frequency in high-particulate industrial environments. The aluminum media provides excellent particulate capture with lightweight construction while the galvanized steel frame and face grids deliver the enhanced structural durability and temperature capability required for industrial applications. Each layer features expanded mesh construction with carefully engineered strand spacing that captures large particulates through multiple interception stages. The seven-layer corrugated structure provides significantly increased surface area within the 2″ nominal depth while the criss-cross weave pattern ensures uniform particle distribution across the entire media pack. This engineering approach delivers effective pre-filtration performance with manageable pressure drop, protecting downstream HVAC components without overburdening system blowers—with galvanized steel construction ensuring the frame and face grids maintain structural integrity even when industrial operating conditions would compromise aluminum alternatives, and with enhanced dust-holding capacity ensuring cleaning intervals remain manageable despite heavy particulate loading.
Corner Drain System
Three strategically positioned corner drain holes facilitate rapid water evacuation following cleaning operations, with typical air-drying times of 30-90 minutes depending on ambient conditions. The open mesh construction and robust galvanized steel frame design enable complete water drainage without trapped moisture in corner joints or frame channels. This drainage system prevents water pooling that could lead to odor development while the hot-dip galvanized coating ensures the frame resists corrosion even with repeated wet-dry cycles throughout the filter’s multi-year service life. The galvanized steel construction naturally resists rust formation in humid environments and moisture-rich applications, maintaining structural integrity and filtration performance through thousands of operational hours and repeated cleaning cycles—delivering consistent dimensional accuracy and reliable filtration in conditions where aluminum frames would experience oxidation and potential warping. The enhanced 1-3/4″ actual depth accommodates the 7-ply media pack while the drain system ensures complete moisture removal regardless of filter depth.
Galvanized Steel Face Grid Protection
Both upstream and downstream faces incorporate 30-gauge galvanized steel protective grids that shield the 7-ply media layers from physical damage during handling, installation, and operation. These galvanized steel face grids distribute incoming airflow uniformly across the entire filter surface, preventing concentrated jet streams that could damage the media structure while maintaining the manageable pressure drop characteristic of 2″ nominal depth filtration with 7-ply media. The grid construction provides impact resistance against accidental contact during filter changeouts while the hot-dip galvanized coating ensures the face grids resist corrosion in humid or corrosive atmospheres where aluminum grids might oxidize. This protective layer ensures the custom-manufactured filter maintains its structural integrity and filtration performance throughout thousands of operational hours and repeated cleaning cycles in heavy-particulate environments, with galvanized steel construction delivering enhanced durability compared to aluminum in demanding industrial and commercial applications with elevated temperatures and continuous dust loading.
Maintenance & Cleaning Protocol
The HIGS20 Custom 2″ Galvanized Steel Washable Mesh Filter requires minimal maintenance while delivering 5-10 years of reliable service in demanding industrial and commercial environments. Unlike disposable filters that create ongoing frustration finding compatible replacements for custom sizes, this industrial-grade galvanized steel mesh filter with 7-ply media supports repeated cleaning cycles using simple water-based methods without expensive cleaning agents or replacement costs—with hot-dip galvanized construction ensuring corrosion resistance throughout years of wet cleaning cycles and with enhanced dust-holding capacity substantially extending cleaning intervals compared to thinner filters.
Cleaning Methods
Four effective cleaning methods accommodate different facility capabilities and contamination levels. Garden hose cleaning provides the simplest approach, using high-pressure nozzle settings to spray both sides of the 7-ply media until water runs clear—typically sufficient for most commercial and light industrial applications, though the 2″ depth requires thorough rinsing of both faces to ensure complete cleaning of the thicker media pack. Sink or tub soaking works well for moderate to heavy contamination, submerging the filter in warm soapy water for 15-30 minutes before rinsing thoroughly (galvanized steel benefits from mild detergent and tolerates more aggressive cleaning agents than aluminum without corrosion concerns, while the 7-ply media may require extended soak time compared to thinner filters). Commercial dishwashers offer hands-free cleaning for facilities with industrial dishwashing equipment, with galvanized construction tolerating standard commercial dishwasher temperatures and detergents without degradation—ensure dishwasher accommodates the 2″ depth dimension. Pressure washing delivers fast results for heavier contamination typical in industrial applications, using 1000-1500 PSI with warm water—galvanized steel’s robust construction tolerates higher pressure than aluminum while the protective zinc coating prevents rust formation even with repeated high-pressure wet cleaning, and the 7-ply media’s enhanced thickness requires thorough pressure washing from both sides to dislodge accumulated particulate from the deeper media pack. The hot-dip galvanized frame and face grids withstand repeated washing without corrosion or degradation, maintaining structural integrity throughout the filter’s service life while operating continuously at 325°F temperature rating.
Recommended Cleaning Frequency
Cleaning intervals depend on operating environment and particulate loading rates, with the HIGS20’s enhanced 97 g/sq ft dust-holding capacity extending intervals substantially compared to 68 g/sq ft 1″ filters. Light dust environments such as standard commercial applications require cleaning every 4-6 months—roughly 50% longer intervals than 1″ filters in equivalent conditions. Moderate industrial applications including manufacturing facilities and commercial operations benefit from cleaning schedules every 6-8 weeks—extended from monthly intervals typical with 1″ filters. High-particulate industrial environments with continuous heavy dust generation may need monthly to bi-monthly cleaning—extended from bi-weekly to monthly intervals required with thinner filters. Visual inspection provides the most reliable cleaning indicator—schedule cleaning when the 7-ply screen wire media appears visibly loaded with dust or when system airflow seems reduced. Monitor pressure drop across the filter if instrumentation is available, cleaning when resistance reaches 0.50″ w.g. to maintain energy-efficient system operation. In humid environments or applications involving frequent moisture exposure, inspect the galvanized steel frame periodically to verify the protective zinc coating maintains its integrity—though properly maintained galvanized filters typically show no corrosion throughout their 5-10 year service life. The enhanced dust-holding capacity of the 2″ depth substantially reduces maintenance labor costs compared to 1″ filters in equivalent high-particulate applications, making the HIGS20 particularly cost-effective in industrial environments where filter accessibility challenges make frequent cleaning expensive.
Handling Considerations for Galvanized Steel Construction
Galvanized steel filters with 2″ depth provide enhanced durability with moderate weight increase compared to aluminum construction and increased weight compared to 1″ depth, tolerating somewhat more aggressive handling and cleaning pressure while still benefiting from proper support during maintenance. Support larger custom sizes from underneath during cleaning and installation to prevent frame stress, particularly important with the increased weight of 2″ depth filters. The 24-gauge galvanized steel frame construction with 1-3/4″ actual depth provides excellent structural rigidity, though heavier custom sizes may require two-person handling for safe installation and removal—the combination of galvanized steel material and 2″ depth creates noticeably heavier filters than aluminum 1″ alternatives. The hot-dip galvanized coating tolerates repeated wet-dry cycles and mechanical cleaning without degradation—maintaining corrosion resistance and dimensional stability throughout years of service in demanding industrial and commercial applications. Avoid using extremely abrasive cleaning tools that might damage the protective zinc coating, though normal pressure washing, detergent cleaning, and standard handling poses no risk to properly galvanized construction. The enhanced media depth requires thorough cleaning from both sides to ensure complete particulate removal from the 7-ply structure.
Installation
Installing the HIGS20 Custom 2″ Galvanized Steel Washable Mesh Filter follows the same straightforward procedures as standard filters, with attention to proper orientation, secure seating, and depth clearance to ensure optimal performance from your custom-manufactured industrial-grade filtration solution with enhanced dust-holding capacity.
Pre-Installation Verification
Before installing your custom galvanized steel 2″ filter, verify the dimensions match your original specifications and that your HVAC system is completely shut down with power disconnected. Inspect the filter housing interior for accumulated dust, debris, or damage that could compromise the seal. The custom-manufactured filter should fit your housing precisely with minimal clearance—if excessive gaps exist, verify you’re installing in the correct location and orientation. Confirm the filter housing accommodates the 2″ nominal (1-3/4″ actual) depth—measure the housing depth to ensure adequate clearance for the thicker filter compared to 1″ alternatives you may have previously used. Check the condition of existing gaskets or sealing surfaces, replacing worn gaskets before installing your new permanent filter. Clean the filter housing interior thoroughly with a vacuum or damp cloth to ensure optimal sealing surfaces. Locate the airflow direction arrow marked on your new custom filter frame, ensuring you understand proper orientation before installation. Note the galvanized steel construction and 2″ depth for documentation in your maintenance records, particularly in industrial environments where tracking filter material specifications and media depth supports compliance and quality management protocols.
Installation Steps
With the HVAC system powered off and locked out, open the filter access door or remove the access panel. Carefully remove any existing filter, noting its orientation and airflow direction. Inspect your new HIGS20 custom galvanized steel 2″ filter and locate the airflow direction arrow clearly marked on the frame. The 2″ nominal (1-3/4″ actual) depth creates increased handling weight compared to 1″ filters, and the galvanized steel construction creates slightly heavier weight than aluminum—larger custom sizes will likely require two-person installation for safety. Insert the filter into the housing with the airflow arrow pointing in the correct direction of air movement through your system. Press the filter firmly into place, ensuring all edges seat properly against the gasket or housing walls without forcing—the 2″ depth requires verification that the filter seats completely within the housing depth. The robust 24-gauge galvanized steel frame construction prevents flexing during installation while the custom dimensions create proper fit without excessive gaps around the perimeter. Verify the increased depth doesn’t interfere with access doors, adjacent components, or housing closure. Secure the access door or panel, restore power, and restart system operation.
Post-Installation Verification
After system restart, listen carefully for any unusual sounds such as air whistling or rattling that might indicate improper seating or depth interference. Verify proper airflow by checking that air velocity at supply registers matches expected performance levels. The slightly higher pressure drop of the 2″ nominal filter with 7-ply media (0.10″ w.g. vs. 0.08″ w.g. for 1″ filters) means system performance should still maintain acceptable levels while providing substantially extended cleaning intervals. Document the installation date, custom dimensions, galvanized steel construction specification, and 2″ depth in your maintenance records for future reordering through your online account. The 43% dust arrestance efficiency with 97 g/sq ft dust-holding capacity begins immediately protecting downstream HVAC components from large particulates and debris while the extended capacity delays the first cleaning interval substantially compared to thinner filters. Establish a regular inspection schedule based on your specific environmental conditions to monitor dust accumulation and maintain optimal system performance throughout the filter’s 5-10 year service life. In humid or corrosive industrial environments, the galvanized steel construction provides peace of mind that the filter will maintain structural integrity and dimensional accuracy throughout years of demanding service where aluminum alternatives might experience premature degradation, while the enhanced dust-holding capacity ensures cleaning intervals remain manageable despite heavy particulate loading.
Complementary Products
The HIGS20 Custom 2″ Galvanized Steel Washable Mesh Filter excels as a pre-filtration stage with extended cleaning intervals, but complete HVAC protection in multi-stage industrial systems may require complementary secondary filtration products. By combining this custom galvanized steel mesh pre-filter with specialized secondary filters, you achieve optimal air quality while protecting expensive downstream filtration equipment in demanding industrial environments with heavy particulate loading.
The 43% dust arrestance efficiency with 97 g/sq ft dust-holding capacity of this custom 2″ galvanized steel mesh pre-filter makes it the ideal first stage for industrial filtration systems requiring custom dimensions where standard filters cannot accommodate unique equipment specifications and where operating conditions demand galvanized steel’s enhanced durability with extended cleaning intervals.
Custom Secondary Filtration (Galvanized Steel)
For systems requiring secondary filtration in custom dimensions with consistent galvanized steel construction:
• Custom 4″ Galvanized Steel Secondary Filter (HIGS40) – Follow your custom 2″ galvanized pre-filter with custom 4″ galvanized secondary filtration for maximum dust-holding capacity and extended cleaning intervals while maintaining consistent material properties.
• Custom 1″ Galvanized Steel Tertiary Filter (HIGS10) – Add custom 1″ galvanized tertiary stage after 2″ pre-filtration for multi-stage industrial applications with space constraints in downstream positions.
Alternative Material Secondary Filters (Custom Dimensions)
For multi-stage systems with different material requirements per stage:
• Custom 2″ Stainless Steel Filter (HISS20) – Upgrade to stainless steel for secondary stage if temperatures exceed 325°F or extreme corrosion resistance required in downstream position.
• Custom 4″ Aluminum Filter (HIAS40) – Cost-effective aluminum secondary stage with maximum depth for applications where pre-filter faces harsher conditions than downstream filtration.
Standard Galvanized Steel Filters (If Dimensions Match)
If your secondary stage uses standard dimensions:
• HIG401620 – 16x20x4 Galvanized Steel Filter – Standard 4-inch galvanized steel filter for maximum secondary filtration dust-holding capacity in industrial applications.
• HIG401224 – 12x24x4 Galvanized Steel Filter – Stock 4-inch galvanized steel secondary filter for immediate availability with maximum capacity.
• HIG201625 – 16x25x2 Galvanized Steel Filter – Standard 2-inch galvanized steel filtration for secondary stage with extended cleaning intervals.
Frequently Asked Questions
Why choose 2″ galvanized steel over 1″ or aluminum?
Choose the HIGS20 (2″ galvanized steel) over alternatives when you need the combined benefits of industrial-grade corrosion resistance AND extended cleaning intervals from enhanced dust-holding capacity. The 2″ depth with 7-ply media provides 97 g/sq ft capacity—42% more than 1″ filters with 5-ply media (68 g/sq ft)—substantially extending cleaning intervals in high-particulate industrial environments. The galvanized steel construction adds 325°F temperature rating (50°F higher than aluminum) and superior rust resistance in humid conditions. Choose 2″ galvanized steel when your application involves elevated temperatures approaching or exceeding aluminum’s 275°F limit, humid environments where aluminum corrodes, AND heavy particulate loading where 1″ filter cleaning frequency becomes impractical. The combination delivers both environmental durability and extended maintenance intervals—providing better long-term value than repeatedly replacing corroded aluminum filters or performing excessive cleaning cycles on 1″ filters in heavy-dust applications.
How much longer can I go between cleanings with the 2″ filter versus 1″ filter?
The HIGS20’s 97 g/sq ft dust-holding capacity versus the HIGS10’s 68 g/sq ft represents 42% more capacity, typically translating to 40-50% longer cleaning intervals in equivalent particulate loading conditions. For example, if you currently clean 1″ filters monthly in your application, the 2″ filter would typically extend intervals to 6-8 weeks. In moderate-dust environments requiring quarterly cleaning with 1″ filters, the 2″ filter might extend to 5-6 months between cleanings. However, actual interval extension depends on your specific particulate characteristics, loading rate, and acceptable pressure drop—monitor your first cleaning cycle with the new 2″ filter to establish optimal interval for your application. The extended intervals reduce maintenance labor costs substantially in applications where filter accessibility challenges make frequent cleaning expensive.
Will the 2″ filter fit in my current 1″ filter housing?
No. The HIGS20 requires a filter housing designed for 2″ nominal (1-3/4″ actual) depth filters. If your current equipment uses 1″ nominal (7/8″ actual) depth filters, you cannot retrofit to 2″ depth without modifying the housing—the 2″ filter is nearly 1 inch deeper than 1″ filters. Before ordering the HIGS20, measure your filter housing depth to confirm it accommodates 2″ nominal filters. If your housing only accepts 1″ depth, order the HIGS10 (Custom 1″ Galvanized Steel) instead, which provides galvanized steel’s enhanced corrosion resistance and temperature capability in the thinner profile, though with lower dust-holding capacity (68 g/sq ft versus 97 g/sq ft).
Does galvanized steel affect filtration efficiency compared to aluminum?
No, material selection does not affect filtration performance. The HIGS20 galvanized steel filter provides identical 43% dust arrestance efficiency and 97 g/sq ft dust-holding capacity as aluminum (HIAS20) or stainless steel (HISS20) construction in 2″ depth. The 7-ply media configuration delivers the same particle capture performance and dust-holding capacity regardless of frame material. Material selection affects temperature rating (aluminum 275°F vs. galvanized 325°F vs. stainless 900°F), corrosion resistance, weight, and cost—but not filtration efficiency or dust-holding capacity. Choose galvanized steel for its enhanced environmental durability and temperature capability while achieving the same filtration performance as other materials, with identical cleaning interval benefits from the 2″ depth media pack.
Is galvanized steel washable and reusable like aluminum?
Yes, the HIGS20 galvanized steel filter is designed for repeated washing and reuse throughout its 5-10 year service life—identical to aluminum and stainless steel service life expectations. The hot-dip galvanized coating withstands repeated cleaning cycles using water-based methods, detergents, pressure washers, or commercial dishwashers without corrosion or degradation. In fact, galvanized steel’s superior rust resistance makes it more tolerant of aggressive cleaning protocols and repeated wet-dry cycles compared to aluminum—maintaining structural integrity and dimensional accuracy through years of regular washing in humid or moisture-rich applications where aluminum might experience oxidation. The 7-ply media requires thorough rinsing from both sides during cleaning to ensure complete particulate removal from the enhanced media depth.
Can I order aluminum, galvanized, or stainless in the same custom 2″ dimensions?
Yes, absolutely. Once you’ve specified your custom dimensions for the HIGS20 galvanized steel 2″ filter, you can order the same size in aluminum (HIAS20) for cost-effective applications or stainless steel (HISS20) for extreme conditions. Many facility managers maintain inventory in multiple materials for different zones—aluminum for standard areas, galvanized steel for humid or elevated temperature zones with heavy particulate, stainless steel for extreme applications. Your custom dimensions are saved in your account, making it easy to reorder in the same or different materials as needs change or as you optimize material selection based on actual operating experience. All three materials provide identical 97 g/sq ft dust-holding capacity and 43% filtration efficiency in 2″ depth.
How long does custom 2″ galvanized steel filter manufacturing take?
Custom galvanized steel 2″ filter manufacturing typically requires 5-10 business days from order confirmation to shipment, though production schedules may vary based on current order volume. Galvanized steel production may add 1-2 days to lead time compared to aluminum due to the hot-dip galvanizing process, but this modest lead time increase delivers substantial performance advantages in demanding applications. The 2″ depth does not significantly affect production time compared to 1″ or 4″ depths. Rush production is available for critical applications requiring faster turnaround. We recommend ordering before your existing filter reaches end-of-service to ensure continuous filtration coverage, particularly in industrial applications where extended lead times for custom-sized galvanized steel filters with enhanced depth might otherwise create operational challenges.
What maintenance does the 2″ galvanized steel filter require?
Galvanized steel 2″ filters require the same simple maintenance as aluminum construction—periodic washing with water-based methods when dust accumulation becomes visible or when pressure drop reaches 0.50″ w.g.—but with substantially extended intervals between cleanings due to the enhanced 97 g/sq ft capacity. The hot-dip galvanized coating requires no special maintenance or treatment, maintaining its corrosion protection throughout the filter’s 5-10 year service life with normal cleaning protocols. Clean using garden hose, sink soaking, commercial dishwasher, or pressure washer depending on facility capabilities and contamination level—ensure thorough rinsing of both faces of the 7-ply media. The galvanized construction tolerates aggressive cleaning methods without degradation—you can use stronger detergents and higher pressure than aluminum without corrosion concerns. The enhanced dust-holding capacity means you’ll perform fewer total cleaning cycles over the filter’s service life compared to 1″ alternatives, reducing cumulative maintenance labor substantially.
Why Choose the HIGS20 Custom 2″ Galvanized Steel Washable Mesh Filter?
Choosing the HIGS20 Custom 2″ Galvanized Steel Washable Mesh Filter eliminates the frustration and expense of searching for compatible replacement filters for HVAC systems with discontinued or non-standard dimensions while providing industrial-grade durability, enhanced corrosion resistance, elevated temperature capability, and substantially extended cleaning intervals that aluminum construction and thinner filters cannot match. Whether you’re maintaining commercial kitchen equipment operating at sustained elevated temperatures with heavy particulate loading, supporting manufacturing facilities with high humidity and continuous dust generation, servicing food processing plants requiring frequent washdown environments with limited maintenance access, or managing industrial systems where premature aluminum corrosion and excessive cleaning frequency have increased operational costs, this made-to-order galvanized steel solution with 7-ply media provides permanent filtration precisely matched to your unique dimensional requirements and demanding operating conditions. The custom manufacturing process ensures perfect dimensional fit while hot-dip galvanized steel construction with enhanced media depth ensures optimal performance, maximum service life in harsh environments, and manageable maintenance intervals despite heavy particulate challenge.
Built to the same rigorous quality standards as our stock HIG Series products, this custom filter features precision-engineered 7-ply media construction and UL 900 Class 1 certification with 325°F continuous temperature rating—50°F higher than aluminum’s limitation. The industry-standard 2″ nominal (1-3/4″ actual) depth profile fits the vast majority of HVAC filter tracks designed for 2-inch filters while the 97 grams per square foot dust-holding capacity extends cleaning intervals by 42% compared to 1″ filters, substantially reducing maintenance frequency and labor costs. Made in USA with premium 24-gauge hot-dip galvanized steel frames and 30-gauge galvanized steel face grids, each custom filter is manufactured to your exact specifications with ±1/8″ tolerance, ensuring precise fit and optimal performance throughout its 5-10 year service life in demanding industrial and commercial applications with heavy continuous particulate loading.
The permanent washable construction delivers exceptional long-term value compared to disposable alternatives—especially critical for custom sizes where finding compatible replacements creates ongoing frustration and expense and where galvanized steel’s enhanced durability extends service life significantly beyond aluminum in harsh operating conditions while the enhanced dust-holding capacity reduces maintenance frequency dramatically. Once you’ve placed your initial custom order, reordering identical galvanized steel 2″ filters is effortless through your online account, eliminating the need to re-measure or re-specify dimensions for future purchases. The 43% dust arrestance efficiency protects downstream HVAC components while the manageable pressure drop maintains acceptable system efficiency even with 7-ply media. Simple water-based cleaning when pressure drop reaches 0.50″ w.g. restores peak performance without expensive cleaning agents or professional services—but you’ll perform these cleanings far less frequently than with 1″ filters—with hot-dip galvanized construction supporting repeated cleaning cycles throughout the filter’s multi-year service life without corrosion or degradation.
Facility managers, property owners, HVAC contractors, and industrial maintenance professionals choose the HIGS20 when standard filters cannot solve their combined dimensional, environmental, and maintenance filtration challenges and when operating conditions demand materials and dust-holding capacity exceeding aluminum’s and thinner filters’ limitations. From maintaining vintage industrial equipment with discontinued filter dimensions and limited maintenance access to supporting harsh manufacturing environments requiring enhanced corrosion resistance, 325°F temperature capability, and extended cleaning intervals, this custom galvanized steel mesh filter with 7-ply media provides the permanent solution that eliminates filter procurement frustration while delivering industrial-grade filtration performance matched to your exact dimensional, environmental, and operational requirements. Invest in a custom-manufactured filter that fits your system perfectly, uses industrial-grade materials engineered for demanding conditions, provides enhanced dust-holding capacity for extended maintenance intervals, delivers up to a decade of reliable service, and ensures you’ll never struggle to find compatible replacements again. Order your custom HIGS20 today and experience the confidence that comes from having a permanent filtration solution precisely matched to every aspect of your unique HVAC system requirements—with galvanized steel construction delivering the enhanced durability and temperature capability your demanding application requires, and with 2″ depth delivering the extended cleaning intervals your maintenance operations demand.
Additional information
| Weight | 4 oz |
|---|---|
| Frame Material | Galvanized Steel |
| GTIN | 00840373527465 |
| MPN | HIGS20 |
Custom Mesh Filter, Stainless Steel, 2 Inch Thick
As low as $0.28 per sq inch
Please provide actual L x W measurements down to the 1/16th inch. Example: “15.25 x 24.1875”. Custom size filters are not returnable so please double check before ordering.
| 1/16 = .0625 | 9/16″ = .5625 |
| 1/8 = .125 | 5/8″ = .625 |
| 3/16 = .1875 | 11/16″ = .6875 |
| 1/4 = .25 | 3/4″ = .75 |
| 5/16 = .3125 | 13/16″ = .8125 |
| 3/8 = .375 | 7/8″ = .875 |
| 7/16 = .4375 | 15/16″ = .9375 |
| 1/2 = .5 | 1″ = 1 |
Description
Product Overview
The HISS20 Custom 2″ Stainless Steel Washable Mesh Filter delivers maximum harsh environment filtration performance with extended cleaning intervals for HVAC systems requiring exceptional corrosion resistance, extreme temperature capability, and enhanced dust-holding capacity in custom dimensions that off-the-shelf products cannot provide. This made-to-order 2″ nominal depth (1-3/4″ actual) stainless steel mesh filter combines 24-gauge Type 304 stainless steel frame construction with 7-ply corrugated criss-cross stainless steel screen wire media and 30-gauge stainless steel face grids, providing 900°F continuous temperature capability and unmatched corrosion resistance for the most extreme industrial environments, highly corrosive chemical processing facilities, foundries, commercial bakeries, and applications where galvanized steel or aluminum construction proves inadequate. Built to UL 900 Class 1 standards with custom manufacturing to your exact dimensional specifications, this premium stainless steel filter ensures reliable pre-filtration performance tailored precisely to your unique HVAC system needs while withstanding the most demanding harsh environment conditions that would compromise alternative materials.
Engineered with precision-formed 24-gauge Type 304 stainless steel frames paired with specialized 7-ply corrugated stainless steel screen wire media and 30-gauge stainless steel face grids, the HISS20 delivers 43% dust arrestance efficiency in the industry-standard 2″ nominal depth profile. This premium-grade all-stainless construction serves extreme environments requiring maximum corrosion resistance, extraordinary temperature handling capability, and chemical resistance that galvanized steel and aluminum cannot provide—from foundries operating at temperatures exceeding 325°F to chemical processing facilities with highly corrosive atmospheres to commercial bakeries with continuous elevated temperature exposure. The deeper 2″ profile significantly extends cleaning intervals compared to 1″ filters while custom manufacturing to your exact specifications in the USA ensures each filter ships ready to install with no modifications required, providing permanent filtration for discontinued equipment, non-standard installations, and harsh environment applications demanding materials that maintain structural integrity and filtration performance in conditions where alternative materials fail prematurely.
Unlike disposable filters requiring constant replacement—especially problematic for custom sizes with discontinued or non-standard dimensions—this custom stainless steel washable mesh filter delivers 5-10 years of continuous service with proper maintenance protocols. The robust all-stainless construction features precision-mitered corners secured with stainless steel pop rivets and 30-gauge stainless steel face grids ensuring structural integrity through repeated cleaning cycles using standard water-based methods, aggressive detergents, and even caustic cleaning agents without corrosion concerns. The enhanced 7-ply media configuration with greater depth dramatically extends the interval between cleanings compared to 1″ filters, reducing maintenance frequency while maintaining peak filtration performance in demanding harsh environment applications. Three strategically placed corner drain holes facilitate complete water removal after washing, preventing moisture retention and accelerating return-to-service time. Once you’ve placed your initial custom order, reordering identical replacements is effortless through your online account, ensuring you’ll never struggle to find the right filter size again while maintaining the maximum harsh environment capability, exceptional corrosion resistance, and extraordinary temperature handling that stainless steel provides.
Facility managers, property owners, and HVAC contractors working with extreme temperature applications, highly corrosive chemical environments, foundries, commercial bakeries, industrial drying operations, or equipment requiring maximum corrosion resistance beyond galvanized steel’s capabilities rely on custom stainless steel washable mesh filters to solve filtration challenges where alternative materials fall short. Whether you’re maintaining foundry ventilation systems operating above 325°F, supporting chemical processing facilities with corrosive vapor atmospheres, servicing commercial bakery ovens requiring continuous elevated temperature capability, or managing industrial drying operations where standard materials degrade prematurely, the HISS20 provides a permanent solution manufactured to your exact specifications with extended cleaning intervals that reduce maintenance burden. With 900°F continuous temperature rating, unmatched corrosion resistance in highly corrosive environments, low initial airflow resistance, dramatically extended cleaning intervals compared to 1″ filters, and the ability to maintain peak performance through repeated cleaning cycles even with aggressive caustic cleaning agents, this custom stainless steel washable mesh filter delivers measurable ROI through eliminated filter replacement costs, reduced maintenance frequency, maximum service life in the most demanding harsh environment conditions, and the peace of mind that comes from having a reliable long-term filtration solution precisely matched to your system dimensions and extreme operating environment.
Key Benefits of the HISS20 Custom 2″ Stainless Steel Washable Mesh Filter
- Premium Type 304 Stainless Steel Construction: 24-gauge Type 304 stainless steel frame with 30-gauge stainless steel face grids and all-stainless 7-ply media provides maximum corrosion resistance and structural integrity in highly corrosive, extreme temperature, or chemical environments where galvanized steel and aluminum construction degrade prematurely.
- 900°F Continuous Temperature Rating: Exceptional 900°F operating temperature—575°F higher than aluminum and 575°F higher than galvanized steel—serves foundries, commercial bakeries, industrial drying operations, and extreme temperature applications that alternative materials cannot handle.
- Extended Cleaning Intervals: 2″ nominal depth with 7-ply media dramatically extends time between cleanings compared to 1″ filters—reducing maintenance frequency, labor costs, and operational disruptions while maintaining superior harsh environment filtration performance.
- Custom Sizing for Any HVAC System: Made-to-order manufacturing accommodates any height and width combination, solving filtration challenges for discontinued equipment, industrial systems, and non-standard installations where off-the-shelf stainless steel filters don’t fit.
- Maximum Harsh Environment Corrosion Resistance: Type 304 stainless steel provides unmatched rust and corrosion resistance in highly corrosive chemical environments, salt-laden coastal atmospheres, caustic cleaning operations, and aggressive industrial atmospheres where galvanized steel’s zinc coating would be compromised.
- Chemical Resistance & Aggressive Cleaning Tolerance: Stainless steel construction tolerates caustic cleaning agents, aggressive detergents, and corrosive cleaning protocols that would damage galvanized or aluminum alternatives—ideal for applications requiring specialized cleaning procedures.
- Effortless Reordering: Once you’ve placed your initial custom order, reordering identical stainless steel filters is simple through your online account—no need to re-measure or re-specify dimensions for future purchases.
Technical Specifications
The HISS20 Custom 2″ Stainless Steel Washable Mesh Filter represents precision-engineered filtration technology manufactured to your exact dimensional specifications with premium Type 304 stainless steel construction. This industry-standard 2″ nominal depth (1-3/4″ actual) stainless steel mesh pre-filter delivers exceptional performance validated through rigorous UL 900 Class 1 testing, ensuring reliable operation in continuous extreme temperature and highly corrosive environments up to 900°F. Every custom filter is built with the same premium-grade construction standards as our stock HIS Series products, providing the maximum harsh environment capability and extraordinary corrosion resistance you expect from all-stainless steel construction with dimensions tailored precisely to your unique HVAC system requirements.
Manufactured in the USA using premium 24-gauge Type 304 stainless steel framing paired with 7-ply corrugated criss-cross stainless steel screen wire media and 30-gauge stainless steel face grids, this custom washable mesh filter meets the stringent requirements of extreme industrial and commercial HVAC applications requiring non-standard filter dimensions with maximum environmental resistance. The 2″ nominal (1-3/4″ actual) depth profile provides optimal balance between cleaning interval extension and HVAC system compatibility while the 43% dust arrestance efficiency protects downstream equipment from premature loading. With 136 grams per square foot dust-holding capacity—double that of 1″ filters—this custom stainless steel filter dramatically extends cleaning intervals and reduces maintenance frequency in applications where finding replacement filters has historically been challenging and where material durability in harsh environments directly impacts service life.
| Specifications: | Details: |
|---|---|
| Model Number | HISS20 (Custom 2″ Stainless Steel) |
| Filter Depth | 2″ nominal (1-3/4″ actual depth) |
| Height & Width | Custom dimensions manufactured to your exact specifications |
| Dimensional Tolerance | ±1/8″ on height and width |
| Frame Material | 24-gauge Type 304 stainless steel |
| Filter Media | 7-ply corrugated criss-cross stainless steel screen wire mesh |
| Face Grid Material | 30-gauge Type 304 stainless steel |
| Frame Construction | Precision-mitered corners, stainless steel pop rivets |
| Drainage | 3 corner drain holes for complete water removal after washing |
| Maximum Operating Temperature | 900°F continuous (UL 900 Class 1 certified) |
| Dust Arrestance Efficiency | 43% average at rated airflow (350 FPM) |
| Dust Holding Capacity | 136 grams per square foot (double 1″ capacity) |
| Rated Airflow | 350 FPM (feet per minute) |
| Recommended Airflow Range | 300-500 FPM face velocity |
| Initial Pressure Drop | 0.10″ w.g. @ 350 FPM (clean filter) |
| Recommended Final Resistance | 0.50″ w.g. (water gauge) before cleaning |
| Weight | Varies by custom dimensions (heavier than aluminum and galvanized) |
| Washability | Repeated cleaning cycles with water-based methods, aggressive detergents, caustic agents, or pressure washers |
| Service Life | 5-10 years with proper maintenance protocols |
| Compliance & Certifications | UL 900 Class 1, ASTM E 2931 (washable filter standard) |
| Country of Origin | Made in USA |
Industrial Applications
The HISS20 Custom 2″ Stainless Steel Washable Mesh Filter solves critical filtration challenges across extreme industrial and commercial applications where maximum corrosion resistance, extraordinary temperature capability, and chemical resistance exceed galvanized steel’s and aluminum’s limitations while extended cleaning intervals reduce maintenance burden and custom dimensions accommodate unique HVAC equipment requirements. From foundries operating at temperatures exceeding 325°F to chemical processing facilities with highly corrosive vapor atmospheres, this premium stainless steel solution with enhanced dust-holding capacity ensures reliable pre-filtration when standard materials, standard sizes, and alternative construction cannot meet your system’s combined dimensional, temperature, harsh environment, and maintenance frequency demands.
Foundries & Extreme Temperature Operations
Foundry operations, metal casting facilities, forge shops, and high-temperature manufacturing environments subject HVAC systems to continuous extreme temperatures that exceed galvanized steel’s 325°F and aluminum’s 275°F limitations. The HISS20’s exceptional 900°F continuous temperature rating serves ventilation systems for foundry operations, metal melting furnaces, forging operations, and high-temperature manufacturing processes where alternative materials would experience structural degradation, warping, or complete failure. Metal casting facilities with continuous elevated ambient temperatures, forge shops with sustained high-temperature exposure near work areas, aluminum smelting operations requiring extreme temperature capability, and specialty metal fabrication facilities with temperatures regularly exceeding 325°F depend on stainless steel construction to maintain filtration performance and structural integrity throughout years of extreme temperature service. The 2″ depth with 7-ply media significantly extends cleaning intervals in these heavy particulate environments—reducing the frequency of filter removal in hazardous high-temperature areas and minimizing maintenance labor exposure to extreme conditions. The permanent washable construction means once you’ve established your custom dimensions and experienced stainless steel’s extraordinary temperature capability in your specific application, reordering identical replacements through your online account ensures consistent filtration performance without the frustration of searching for compatible custom-sized alternatives with adequate temperature ratings.
Commercial Bakeries & Food Processing
Commercial bakery operations, large-scale food production facilities, and industrial baking operations require HVAC filtration near commercial ovens, proofing chambers, and baking equipment operating continuously at elevated temperatures that compromise aluminum and galvanized steel materials. The HISS20’s 900°F temperature rating and food-grade Type 304 stainless steel construction serve ventilation systems for commercial bread ovens, industrial cookie production lines, large-scale baking operations, and specialty food manufacturing where oven proximity creates sustained elevated ambient temperatures. Multi-deck commercial ovens with ventilation systems exposed to radiant heat, conveyor-style industrial baking lines with continuous elevated temperature exposure, specialty bakeries with artisan ovens generating sustained high temperatures, and food production facilities requiring food-grade materials depend on stainless steel’s extraordinary temperature capability and corrosion resistance. The enhanced 2″ depth dramatically extends cleaning intervals in flour dust-heavy bakery environments—reducing maintenance disruptions during peak production hours while the all-stainless construction tolerates aggressive cleaning protocols required in food production environments, maintaining structural integrity through repeated washdown cycles with food-safe sanitizers and caustic cleaning agents.
Chemical Processing & Corrosive Environments
Chemical processing facilities, pharmaceutical manufacturing operations, electroplating facilities, and industrial operations involving corrosive vapors or aggressive atmospheres require filtration materials that resist chemical attack beyond galvanized steel’s capabilities. The HISS20’s Type 304 stainless steel construction provides maximum corrosion resistance to acidic vapors, alkaline atmospheres, salt spray, chlorine exposure, and chemical environments where galvanized steel’s zinc coating would be compromised or aluminum would experience rapid degradation. Chemical manufacturing plants with acid vapor exposure, electroplating facilities with caustic fume generation, pharmaceutical production cleanrooms requiring corrosion-resistant materials, and coastal industrial facilities exposed to severe salt-laden atmospheres depend on stainless steel construction when equipment dimensions require custom manufacturing and when operating conditions demand materials exceeding galvanized steel’s and aluminum’s chemical resistance limitations. The 2″ depth with enhanced dust-holding capacity extends cleaning intervals in particulate-laden corrosive environments, reducing the frequency of filter handling in hazardous chemical atmospheres and minimizing personnel exposure during maintenance operations. The 5-10 year service life with proper maintenance delivers exceptional ROI in corrosive applications where filter accessibility challenges make frequent replacements costly and where stainless steel’s maximum corrosion resistance directly reduces maintenance labor and premature filter replacement.
Industrial Drying Operations & Continuous Elevated Temperature
Industrial drying operations, powder coating curing ovens, paint drying systems, and manufacturing processes involving continuous elevated temperature exposure benefit from stainless steel’s 900°F rating and structural stability under sustained thermal cycling. Powder coating facilities with curing ovens generating sustained elevated ambient temperatures, industrial paint drying operations with continuous heat exposure, textile drying operations with high-temperature air handling, and specialty manufacturing requiring elevated temperature capability depend on stainless steel construction to maintain filtration performance when alternative materials would experience premature failure. The HISS20 serves these continuous elevated temperature applications with custom dimensions matching discontinued equipment specifications while providing temperature capability and structural stability that extends service life significantly beyond galvanized steel’s 325°F limitation and aluminum’s 275°F constraint. The 2″ depth extends cleaning intervals in these high-temperature particulate environments, reducing maintenance frequency and improving operational efficiency while the enhanced dust-holding capacity accommodates the heavy particulate loading typical of industrial drying and curing operations. Facility managers maintaining industrial drying systems with older HVAC equipment using non-standard filter sizes, powder coating operations requiring maximum temperature capability with reduced maintenance frequency, and specialty manufacturing with sustained elevated temperature exposure depend on stainless steel construction to maintain dimensional accuracy and filtration performance through years of thermal cycling between ambient and extreme operating temperatures.
Discontinued Equipment & Legacy Extreme Environment Systems
Industrial facilities maintaining older equipment in extreme environments face compounded challenges when original manufacturers discontinue filter production AND when operating environments require stainless steel’s maximum harsh environment capability rather than standard aluminum or galvanized steel construction. Vintage commercial equipment serving foundries, legacy industrial ventilation systems in chemical processing facilities with non-standard dimensions, European-manufactured extreme temperature HVAC equipment using metric sizing, and specialty extreme environment applications with custom filter requirements benefit from the HISS20’s combination of made-to-order dimensional flexibility and premium stainless steel construction with extended cleaning intervals. The custom manufacturing process ensures exact dimensional match to original specifications while stainless steel provides the extraordinary temperature capability and maximum corrosion resistance required by extreme operating conditions. The 2″ depth delivers the extended cleaning intervals that reduce maintenance burden on aging equipment where filter access may be difficult or time-consuming. Once you’ve specified your custom dimensions and confirmed stainless steel performance in your specific harsh environment, future reorders through your online account maintain consistent filtration capability without the perpetual frustration of searching for compatible custom-sized extreme-duty replacement filters.
Material Selection Guide
The HISS20 features premium Type 304 stainless steel construction specifically engineered for extreme temperature applications and highly corrosive environments requiring maximum harsh environment capability beyond galvanized steel’s and aluminum’s limitations. Understanding when stainless steel provides essential performance—compared to cost-effective aluminum or industrial-grade galvanized steel—ensures optimal material selection, maximum service life, and return on investment based on your specific extreme operating environment.
HIS: 304 Stainless Steel Construction (Premium Grade – Harsh Environment)
The Type 304 stainless steel construction features 24-gauge stainless steel frame with 7-ply stainless steel screen wire media and 30-gauge stainless steel face grids, delivering exceptional 900°F continuous temperature rating and maximum corrosion resistance for the most extreme and harsh environment applications. The chromium-nickel alloy composition provides unmatched resistance to corrosion from acidic vapors, alkaline atmospheres, salt spray, chemical exposure, and aggressive industrial environments while maintaining structural integrity at temperatures up to 900°F—575°F higher than galvanized steel and 575°F higher than aluminum. Choose stainless steel when your application involves extreme temperatures exceeding 325°F (foundries, commercial bakeries, industrial drying operations, forge shops), highly corrosive chemical environments with acid or alkaline vapor exposure, salt-laden coastal atmospheres requiring maximum corrosion resistance, operations requiring caustic cleaning agents that would damage alternative materials, or when maximum 5-10 year service life in extraordinarily harsh environments justifies premium investment. Stainless steel excels in foundries, commercial bakery ovens, chemical processing facilities, powder coating curing operations, industrial drying systems, pharmaceutical cleanrooms, electroplating facilities, and extreme corrosion or temperature applications where galvanized steel’s 325°F rating or zinc coating protection proves inadequate. Note that service life for stainless steel is 5-10 years—the same as galvanized steel and aluminum—with stainless steel’s advantage being its ability to achieve this service life in extremely harsh environments rather than extended longevity in standard conditions. The premium cost is justified when extreme temperature or corrosion conditions make alternative materials unsuitable.
HIG: Galvanized Steel Construction (Industrial Grade)
Galvanized steel construction with 325°F temperature rating provides enhanced corrosion resistance and elevated temperature capability at moderate cost, serving most industrial applications effectively. With hot-dip galvanized coating for exceptional rust resistance and 50°F higher temperature rating than aluminum, galvanized steel handles humid environments, moderate corrosion exposure, and temperatures up to 325°F. Consider upgrading to stainless steel (HISS20) when your application involves extreme temperatures exceeding 325°F, highly corrosive chemical environments beyond galvanized steel’s zinc coating protection, salt spray or acidic vapor exposure that would compromise zinc coating, or when caustic cleaning agents are required. For temperatures between 275-325°F and moderate corrosion environments, galvanized steel (HIGS20) provides optimal cost-effectiveness—reserve stainless steel for truly extreme applications where galvanized steel’s capabilities prove inadequate.
HIA: Aluminum Construction (Standard Grade)
Aluminum construction with 275°F temperature rating provides the most cost-effective filtration solution for standard commercial and residential HVAC applications with normal indoor temperatures and dry environments. Aluminum serves the majority of HVAC environments at lowest initial cost with excellent performance in non-extreme conditions. Consider upgrading to stainless steel (HISS20) when your application involves temperatures approaching or exceeding 275°F, highly corrosive environments, chemical vapor exposure, or when previous aluminum filters have shown rapid degradation due to environmental conditions. For extreme applications requiring maximum temperature capability or harsh environment corrosion resistance, stainless steel’s premium cost delivers necessary performance that aluminum cannot provide.
Depth Comparison & Selection Guide
Choosing the optimal filter depth balances dust-holding capacity, cleaning frequency, and system compatibility. The HISS20’s 2″ nominal depth provides the ideal middle ground for most extreme environment applications requiring extended cleaning intervals without the space constraints of deeper 4″ filters.
HISS10: 1″ Nominal Depth (Standard Profile)
The 1″ nominal (7/8″ actual) depth fits the vast majority of HVAC filter tracks with 5-ply media providing 68 g/sq ft dust-holding capacity. Choose 1″ depth when space is limited, when filter track depth is restricted to 1″ nominal, or when your application involves light to moderate particulate loading where frequent cleaning is acceptable. The 1″ profile serves standard extreme temperature applications, chemical processing with light particulate, and situations where the slimmer profile is required for equipment compatibility. Upgrade to 2″ (HISS20) when cleaning frequency becomes burdensome or when particulate loading justifies enhanced capacity.
HISS20: 2″ Nominal Depth (Extended Intervals) – THIS PRODUCT
The 2″ nominal (1-3/4″ actual) depth provides optimal balance between cleaning interval extension and system compatibility with 7-ply media delivering 136 g/sq ft dust-holding capacity—double that of 1″ filters. Choose 2″ depth when you need to reduce maintenance frequency in harsh environments, when particulate loading is moderate to heavy, when system downtime for filter maintenance is costly, or when your filter tracks accommodate 2″ nominal depth. The 2″ profile dramatically extends cleaning intervals in foundries with heavy particulate, commercial bakeries with flour dust accumulation, industrial drying operations with continuous particulate generation, and chemical processing facilities where reducing filter handling in hazardous atmospheres improves safety. The 2″ depth provides the sweet spot for most extreme environment applications—significant interval extension without the depth requirements of 4″ filters. Upgrade to 4″ (HISS40) only when maximum dust-holding capacity and longest possible cleaning intervals justify the deeper profile.
HISS40: 4″ Nominal Depth (Maximum Capacity)
The 4″ nominal (3-3/4″ actual) depth provides maximum dust-holding capacity with 9-ply media delivering 204 g/sq ft capacity—triple that of 1″ filters and 50% more than 2″ filters. Choose 4″ depth when cleaning intervals must be extended to quarterly or even annual frequency, when particulate loading is extremely heavy, when labor costs make frequent maintenance prohibitively expensive, or when remote/difficult filter access justifies maximum capacity. Reserve 4″ depth for extreme environment applications where maintenance reduction is critical: foundries with continuous heavy particulate generation, large commercial bakeries requiring minimal operational disruption, industrial facilities with difficult filter access in extreme conditions, or high-temperature applications where reducing personnel exposure to hazardous areas justifies the deeper profile and higher initial investment.
Construction Features
The HISS20 Custom 2″ Stainless Steel Washable Mesh Filter is engineered with precision manufacturing techniques and premium Type 304 stainless steel materials that ensure every custom-sized unit meets rigorous quality standards for maximum harsh environment durability, extraordinary temperature capability, and exceptional corrosion resistance. UL 900 Class 1 certification validates continuous operation capability at 900°F, while Made in USA construction guarantees dimensional accuracy and structural integrity throughout the filter’s 5-10 year service life in the most extreme industrial environments.
Type 304 Stainless Steel Frame Construction
The foundation of this custom filter begins with a precision-formed 24-gauge Type 304 stainless steel frame, featuring chromium-nickel alloy composition that provides maximum corrosion resistance and extraordinary temperature capability. Type 304 stainless steel resists corrosion from acidic environments, alkaline atmospheres, salt spray, chemical exposure, and aggressive industrial conditions that would compromise galvanized steel’s zinc coating or aluminum’s oxide layer. The 24-gauge thickness delivers excellent structural rigidity while the stainless steel composition ensures the frame maintains dimensional stability and structural integrity throughout repeated thermal cycling between ambient and extreme operating temperatures up to 900°F. Professional-grade mitered corners secured with Type 304 stainless steel pop rivets ensure the frame maintains perfect dimensional accuracy to your custom specifications throughout repeated cleaning cycles—even with aggressive caustic cleaning agents—and years of service in the most demanding harsh environment conditions. Each custom frame is manufactured to your exact height and width requirements with ±1/8″ tolerance, ensuring precise fit without gaps or binding in your HVAC system’s filter tracks while the stainless steel construction prevents the corrosion-induced dimensional changes and thermal degradation that can compromise alternative materials in extreme applications.
Premium 7-Ply Stainless Steel Media Pack
The filtration media consists of seven layers of corrugated Type 304 stainless steel screen wire arranged in a precision criss-cross weave pattern specifically engineered for 2″ nominal depth applications. This all-stainless 7-ply configuration achieves 43% dust arrestance efficiency while maintaining low airflow resistance of just 0.10″ w.g. at rated airflow. The stainless steel media provides excellent particulate capture while delivering the extraordinary temperature capability and maximum corrosion resistance required for extreme and harsh environment applications. Each layer features expanded mesh construction with carefully engineered strand spacing that captures large particulates through multiple interception stages. The corrugated structure provides increased surface area within the 2″ nominal depth while the criss-cross weave pattern ensures uniform particle distribution across the entire media pack. The enhanced 7-ply configuration—compared to 5-ply in 1″ filters—significantly extends cleaning intervals by providing double the dust-holding capacity (136 g/sq ft vs 68 g/sq ft), reducing maintenance frequency while maintaining optimal airflow performance. This all-stainless engineering approach delivers effective pre-filtration performance with minimal pressure drop, protecting downstream HVAC components without overburdening system blowers—with stainless steel construction ensuring the entire filter assembly maintains structural integrity and filtration performance even when extreme operating conditions would compromise galvanized steel’s zinc coating or cause aluminum degradation.
Corner Drain System
Three strategically positioned corner drain holes facilitate rapid water evacuation following cleaning operations, with typical air-drying times of 60-120 minutes depending on ambient conditions and the enhanced media thickness. The open mesh construction and robust stainless steel frame design enable complete water drainage without trapped moisture in corner joints or frame channels. This drainage system prevents water pooling that could lead to odor development while the Type 304 stainless steel construction ensures the frame resists corrosion even with repeated wet-dry cycles, aggressive caustic cleaning agents, and exposure to corrosive cleaning protocols throughout the filter’s multi-year service life. The stainless steel construction naturally resists rust formation and chemical attack in all environments, maintaining structural integrity and filtration performance through thousands of operational hours at extreme temperatures and repeated cleaning cycles with aggressive agents—delivering consistent dimensional accuracy and reliable filtration in harsh environment conditions where galvanized steel’s zinc coating would be compromised or aluminum would experience severe degradation.
Stainless Steel Face Grid Protection
Both upstream and downstream faces incorporate 30-gauge Type 304 stainless steel protective grids that shield the 7-ply media layers from physical damage during handling, installation, and operation. These stainless steel face grids distribute incoming airflow uniformly across the entire filter surface, preventing concentrated jet streams that could damage the media structure while maintaining the low pressure drop characteristic of 2″ nominal depth filtration. The grid construction provides impact resistance against accidental contact during filter changeouts while the stainless steel composition ensures the face grids resist corrosion and maintain structural integrity in highly corrosive chemical atmospheres, salt-laden environments, and extreme temperature applications where alternative materials would fail. This protective layer ensures the custom-manufactured filter maintains its structural integrity and filtration performance throughout thousands of operational hours at extreme temperatures, repeated cleaning cycles with caustic agents, and continuous exposure to harsh environment conditions—with all-stainless construction delivering maximum durability in demanding industrial and commercial applications that exceed galvanized steel’s and aluminum’s capabilities.
Maintenance & Cleaning Protocol
The HISS20 Custom 2″ Stainless Steel Washable Mesh Filter requires minimal maintenance while delivering 5-10 years of reliable service in the most extreme industrial and commercial environments. Unlike disposable filters that create ongoing frustration finding compatible replacements for custom sizes, this premium stainless steel mesh filter supports repeated cleaning cycles using simple water-based methods, aggressive detergents, and even caustic cleaning agents without corrosion concerns—with Type 304 stainless steel construction ensuring maximum durability throughout years of cleaning cycles in harsh environments.
Cleaning Methods
Four effective cleaning methods accommodate different facility capabilities and contamination levels. Garden hose cleaning provides the simplest approach, using high-pressure nozzle settings to spray both sides of the 7-ply media until water runs clear—typically sufficient for most commercial and light industrial applications (note that the 2″ depth requires more thorough rinsing to ensure complete particulate removal from deeper media layers). Sink or tub soaking works well for moderate to heavy contamination, submerging the filter in warm soapy water for 20-40 minutes before rinsing thoroughly (stainless steel tolerates aggressive detergents, caustic cleaning agents, and corrosive cleaning solutions that would damage galvanized or aluminum construction—longer soak times accommodate the enhanced depth). Commercial dishwashers offer hands-off cleaning for facilities with industrial dishwashing equipment, with stainless steel construction tolerating extreme temperatures and harsh commercial detergents without degradation (verify dishwasher rack capacity accommodates 2″ depth). Pressure washing delivers fast results for heavy contamination typical in extreme-particulate industrial applications, using 1000-1500 PSI with warm water—stainless steel’s robust construction tolerates maximum pressure and aggressive cleaning without corrosion while maintaining structural integrity throughout repeated high-pressure wet cleaning cycles (thoroughly clean both sides and edges to ensure complete particulate removal from 7-ply media). The Type 304 stainless steel frame, media, and face grids withstand repeated washing with caustic agents, acidic cleaners, or alkaline detergents without corrosion or degradation, maintaining structural integrity throughout the filter’s service life while operating continuously at temperatures up to 900°F.
Recommended Cleaning Frequency
Cleaning intervals depend on operating environment and particulate loading rates, with the 2″ depth significantly extending intervals compared to 1″ filters. Light dust environments such as standard commercial applications require cleaning every 6-9 months (double the 1″ filter interval). Moderate industrial applications including manufacturing facilities and commercial operations benefit from quarterly to semi-annual cleaning schedules (compared to monthly for 1″ filters). High-particulate industrial environments with continuous dust generation may need monthly to bi-monthly cleaning to maintain optimal system performance (compared to bi-weekly for 1″ filters). The enhanced dust-holding capacity of 136 g/sq ft—double that of 1″ filters—means the HISS20 can accumulate significantly more particulate before cleaning is required, reducing maintenance frequency and improving operational efficiency. Visual inspection provides the most reliable cleaning indicator—schedule cleaning when the 7-ply screen wire media appears visibly loaded with dust or when system airflow seems reduced. Monitor pressure drop across the filter if instrumentation is available, cleaning when resistance reaches 0.50″ w.g. to maintain energy-efficient system operation. In harsh corrosive environments or applications involving chemical exposure, the Type 304 stainless steel construction maintains its integrity indefinitely—properly maintained stainless steel filters show no corrosion throughout their 5-10 year service life even in the most aggressive chemical and temperature environments.
Handling Considerations for Stainless Steel Construction
Stainless steel filters provide maximum durability with heavier weight compared to galvanized steel and aluminum construction, tolerating aggressive handling, caustic cleaning agents, and extreme pressure washing while still benefiting from proper support during maintenance. Support larger custom sizes from underneath during cleaning and installation to prevent frame stress. The 24-gauge stainless steel frame construction provides exceptional structural rigidity, though the 2″ depth with enhanced media weight makes these filters noticeably heavier than 1″ versions—most custom sizes benefit from two-person handling for safe installation and removal. The Type 304 stainless steel construction tolerates repeated wet-dry cycles, caustic cleaning agents, acidic or alkaline cleaners, and aggressive mechanical cleaning without degradation—maintaining corrosion resistance, structural integrity, and dimensional stability throughout years of service in the most demanding harsh environment applications. Stainless steel construction resists damage from all standard cleaning protocols, making it the optimal choice when aggressive cleaning procedures are required or when chemical exposure demands maximum material durability.
Installation
Installing the HISS20 Custom 2″ Stainless Steel Washable Mesh Filter follows the same straightforward procedures as standard filters, with attention to proper orientation and secure seating to ensure optimal performance from your custom-manufactured premium-grade harsh environment filtration solution.
Pre-Installation Verification
Before installing your custom stainless steel filter, verify the dimensions match your original specifications and that your HVAC system is completely shut down with power disconnected. Inspect the filter housing interior for accumulated dust, debris, or damage that could compromise the seal. The custom-manufactured filter should fit your housing precisely with minimal clearance—if excessive gaps exist, verify you’re installing in the correct location and orientation. Check the condition of existing gaskets or sealing surfaces, replacing worn gaskets before installing your new permanent filter. Clean the filter housing interior thoroughly with a vacuum or damp cloth to ensure optimal sealing surfaces. Locate the airflow direction arrow marked on your new custom filter frame, ensuring you understand proper orientation before installation. Verify that your filter tracks accommodate 2″ nominal depth—the HISS20 requires 2″ nominal filter track depth and will not fit in tracks designed for 1″ filters only. Note the stainless steel construction for documentation in your maintenance records, particularly in extreme environment applications where tracking filter material specifications supports compliance and quality management protocols and where the 900°F temperature rating and maximum corrosion resistance are critical performance requirements.
Installation Steps
With the HVAC system powered off and locked out, open the filter access door or remove the access panel. Carefully remove any existing filter, noting its orientation and airflow direction. Inspect your new HISS20 custom stainless steel filter and locate the airflow direction arrow clearly marked on the frame. The 2″ nominal (1-3/4″ actual) depth provides comfortable handling for smaller sizes, though the stainless steel construction creates heavier weight than galvanized steel or aluminum—most custom sizes benefit from two-person installation for safety. Insert the filter into the housing with the airflow arrow pointing in the correct direction of air movement through your system. Press the filter firmly into place, ensuring all edges seat properly against the gasket or housing walls without forcing. The robust 24-gauge stainless steel frame construction prevents flexing during installation while the custom dimensions create proper fit without excessive gaps around the perimeter. Verify the filter is fully seated in the 2″ nominal depth track—the enhanced depth requires proper track engagement to prevent bypass airflow around the filter. Secure the access door or panel, restore power, and restart system operation.
Post-Installation Verification
After system restart, listen carefully for any unusual sounds such as air whistling or rattling that might indicate improper seating. Verify proper airflow by checking that air velocity at supply registers matches expected performance levels. The low pressure drop of the 2″ nominal filter means system performance should match or exceed previous levels with superior harsh environment filtration capability and extended cleaning intervals. Document the installation date, custom dimensions, 2″ depth specification, and stainless steel construction specification in your maintenance records for future reordering through your online account. The 43% dust arrestance efficiency begins immediately protecting downstream HVAC components from large particulates and debris while the 900°F temperature rating and maximum corrosion resistance ensure filtration performance in extreme environments. Establish a regular inspection schedule based on your specific environmental conditions to monitor dust accumulation and maintain optimal system performance throughout the filter’s 5-10 year service life. In extreme temperature or highly corrosive industrial environments, the Type 304 stainless steel construction provides peace of mind that the filter will maintain structural integrity, dimensional accuracy, and filtration performance throughout years of demanding service in conditions where galvanized steel’s zinc coating would be compromised and aluminum would experience premature failure.
Complementary Products
The HISS20 Custom 2″ Stainless Steel Washable Mesh Filter excels as a pre-filtration stage in extreme environments, but complete HVAC protection in multi-stage harsh environment systems may require complementary secondary filtration products. By combining this custom stainless steel mesh pre-filter with specialized secondary filters, you achieve optimal air quality while protecting expensive downstream filtration equipment in the most demanding industrial extreme temperature and corrosive environments.
The 43% dust arrestance efficiency of this custom 2″ stainless steel mesh pre-filter makes it the ideal first stage for extreme environment filtration systems requiring custom dimensions where standard filters cannot accommodate unique equipment specifications and where operating conditions demand stainless steel’s maximum harsh environment capability with extended cleaning intervals.
Custom Secondary Filtration (Stainless Steel, Greater Depth)
For systems requiring secondary filtration in custom dimensions with consistent stainless steel construction and maximum capacity:
• Custom 4″ Stainless Steel Secondary Filter (HISS40) – Follow your custom 2″ stainless pre-filter with custom 4″ stainless secondary filtration for maximum particle capture, longest cleaning intervals, and consistent extreme temperature capability and maximum corrosion resistance throughout your filtration system.
Custom Pre-Filtration (Stainless Steel, Reduced Depth)
For multi-stage systems where the HISS20 serves as secondary filtration:
• Custom 1″ Stainless Steel Pre-Filter (HISS10) – Use custom 1″ stainless pre-filter before 2″ secondary stage to extend the secondary filter’s life while maintaining consistent extreme temperature capability and maximum corrosion resistance throughout the filtration system.
Alternative Material Secondary Filters (Custom Dimensions)
For multi-stage systems where pre-filter faces harsher conditions than secondary stages:
• Custom 1″ Aluminum Filter (HIAS10) – Cost-effective aluminum pre-filter stage for applications where secondary HISS20 requires stainless steel’s extreme temperature capability but upstream positions operate in standard temperature ranges.
• Custom 2″ Galvanized Steel Filter (HIGS20) – Industrial-grade galvanized secondary stage at same depth for applications where pre-filter requires stainless steel’s extreme temperature capability but downstream positions operate within galvanized steel’s 325°F rating.
Standard Stainless Steel Filters (If Dimensions Match)
If your secondary stage uses standard dimensions:
• HIS401620 – 16x20x4 Stainless Steel Filter – Deep 4-inch stainless steel filtration for maximum secondary stage dust-holding capacity in extreme environments.
• HIS402424 – 24x24x4 Stainless Steel Filter – Large 4-inch stainless steel secondary filter for commercial systems requiring maximum capacity with 900°F rating.
• HIS101224 – 12x24x1 Stainless Steel Filter – Stock 1-inch stainless steel pre-filter for immediate availability when using HISS20 as secondary stage.
Frequently Asked Questions
How much longer do cleaning intervals last with 2″ vs 1″ filters?
The HISS20 2″ filter with 7-ply media provides 136 g/sq ft dust-holding capacity—exactly double the 68 g/sq ft capacity of HISS10 1″ filters with 5-ply media. In real-world applications, this typically extends cleaning intervals by 80-100%. If you currently clean 1″ filters monthly, upgrading to 2″ filters typically extends intervals to every 2 months. If you clean 1″ filters quarterly, 2″ filters often extend to semi-annual cleaning. The exact interval depends on your specific particulate loading, but the doubled dust-holding capacity consistently reduces maintenance frequency by approximately half, significantly reducing labor costs and operational disruptions in harsh environment applications where filter access may be difficult or time-consuming.
Will 2″ filters fit in my current filter tracks?
No, the HISS20 requires filter tracks designed for 2″ nominal depth filters. The 2″ nominal (1-3/4″ actual) filter will not fit in tracks designed for 1″ nominal (7/8″ actual) filters. Before ordering, verify your HVAC system’s filter housing accommodates 2″ nominal depth. If your current system uses 1″ filters, upgrading to 2″ depth requires either modifying filter tracks or replacing filter housings—contact your HVAC contractor to assess feasibility. Many commercial and industrial HVAC systems offer adjustable or multi-depth filter tracks that can accommodate different depths. If track modification isn’t feasible, the HISS10 1″ stainless steel filter provides the same 900°F rating and maximum corrosion resistance in the slimmer profile that fits your existing tracks.
When should I choose 2″ instead of 1″ or 4″ stainless steel filters?
Choose 2″ (HISS20) when you need extended cleaning intervals beyond 1″ capacity but your system cannot accommodate 4″ depth, when maintenance frequency reduction justifies moderate upgrade cost, or when your tracks accommodate 2″ nominal depth. The 2″ depth provides the optimal balance for most harsh environment applications—significantly extended intervals (double 1″ capacity) without the space requirements, deeper profile, or higher cost of 4″ filters. Choose 1″ (HISS10) when space is limited or light particulate loading doesn’t justify enhanced capacity. Choose 4″ (HISS40) only when maximum capacity is critical: extremely heavy particulate loading, quarterly or annual cleaning requirements, or difficult filter access in extreme conditions where maintenance frequency reduction justifies premium investment.
Does stainless steel last longer than galvanized steel or aluminum?
Service life for properly maintained washable mesh filters is 5-10 years regardless of material—aluminum, galvanized steel, and stainless steel all achieve this lifespan with proper maintenance. The difference is WHERE each material achieves this service life. Aluminum achieves 5-10 years in standard environments below 275°F with low corrosion. Galvanized steel achieves 5-10 years in industrial environments up to 325°F with moderate corrosion. Stainless steel achieves 5-10 years in EXTREME environments up to 900°F with maximum corrosion exposure. Stainless steel’s advantage is its ability to deliver full service life in harsh environments where alternative materials would fail prematurely—not extended longevity in standard conditions. Choose stainless steel based on your extreme operating environment, not for longer service life.
Can I use 2″ stainless steel filters in multi-stage filtration systems?
Yes, the HISS20 excels in multi-stage harsh environment filtration systems. Use as first-stage pre-filter before higher-efficiency secondary filters to extend secondary filter life while maintaining extreme temperature capability throughout the system. Use as second-stage filter after 1″ stainless steel pre-filter (HISS10) for enhanced particle capture with extended cleaning intervals. The 2″ depth provides excellent balance in multi-stage systems—sufficient capacity to significantly extend intervals without the cost and space requirements of 4″ filters. In extreme environment multi-stage systems, consistent stainless steel construction throughout all stages ensures temperature capability and corrosion resistance isn’t compromised at any point in the filtration chain.
How does weight compare to galvanized steel and aluminum 2″ filters?
Stainless steel filters are heavier than equivalent galvanized steel or aluminum filters due to stainless steel’s higher material density. A custom HISS20 2″ stainless steel filter typically weighs 15-20% more than the equivalent HIGS20 2″ galvanized steel filter, and 35-50% more than an equivalent HIAS20 2″ aluminum filter. The exact weight varies by custom dimensions. Larger custom sizes (20×25″ and above) benefit from two-person handling during installation and removal. The enhanced weight reflects the premium Type 304 stainless steel construction that provides 900°F temperature capability, maximum corrosion resistance, and caustic cleaning tolerance—performance characteristics that justify the modest weight increase for extreme environment applications.
Can I order the same custom dimensions in different materials and depths?
Yes, absolutely. Once you’ve specified your custom dimensions for the HISS20 stainless steel filter, you can order the same size in galvanized steel (HIGS20) for industrial-grade applications, aluminum (HIAS20) for cost-effective standard applications, or different depths (HISS10 for 1″, HISS40 for 4″) in the same stainless steel material. Many facility managers maintain inventory in multiple materials and depths for different zones—aluminum for standard areas, galvanized steel for industrial zones, stainless steel 1″ for space-constrained extreme temperature areas, stainless steel 2″ for general extreme environment applications, stainless steel 4″ for maximum capacity requirements. Your custom dimensions are saved in your account for easy reordering in any material/depth combination.
How long does custom stainless steel filter manufacturing take?
Custom stainless steel filter manufacturing typically requires 5-10 business days from order confirmation to shipment, though production schedules may vary based on current order volume. Stainless steel production may add 1-2 days to lead time compared to aluminum or galvanized steel due to specialized stainless steel processing. The 2″ depth doesn’t significantly affect production time compared to 1″ or 4″ depths. Rush production is available for critical applications. We recommend ordering before your existing filter reaches end-of-service to ensure continuous filtration coverage, particularly in extreme environment applications where extended lead times might otherwise create operational challenges in harsh condition environments.
Why Choose the HISS20 Custom 2″ Stainless Steel Washable Mesh Filter?
Choosing the HISS20 Custom 2″ Stainless Steel Washable Mesh Filter eliminates the frustration and expense of searching for compatible replacement filters for HVAC systems with discontinued or non-standard dimensions while providing maximum harsh environment capability, exceptional corrosion resistance, extraordinary 900°F temperature capability, and dramatically extended cleaning intervals that galvanized steel and aluminum construction cannot match. Whether you’re maintaining foundry ventilation systems operating above 325°F, supporting chemical processing facilities with highly corrosive vapor atmospheres, servicing commercial bakery ovens requiring continuous extreme temperature capability with reduced maintenance frequency, or managing industrial drying operations where standard materials degrade prematurely and where cleaning frequency impacts operational efficiency, this made-to-order premium stainless steel solution provides permanent filtration precisely matched to your unique dimensional requirements and extreme operating conditions. The custom manufacturing process ensures perfect dimensional fit while Type 304 stainless steel construction ensures optimal performance and maximum service life in harsh environments where alternative materials prove inadequate—all with extended cleaning intervals that reduce maintenance burden by approximately half compared to 1″ filters.
Built to the same rigorous quality standards as our stock HIS Series products, this custom filter features precision-engineered 7-ply all-stainless media construction and UL 900 Class 1 certification with exceptional 900°F continuous temperature rating—575°F higher than galvanized steel’s 325°F limitation and 625°F higher than aluminum’s 275°F constraint. The industry-standard 2″ nominal (1-3/4″ actual) depth profile provides optimal balance between cleaning interval extension and system compatibility, delivering 136 g/sq ft dust-holding capacity—exactly double that of 1″ filters—while maintaining excellent airflow performance. Made in USA with premium 24-gauge Type 304 stainless steel frames, all-stainless media, and 30-gauge stainless steel face grids, each custom filter is manufactured to your exact specifications with ±1/8″ tolerance, ensuring precise fit and optimal performance throughout its 5-10 year service life in the most extreme industrial and commercial applications.
The permanent washable construction delivers exceptional long-term value compared to disposable alternatives—especially critical for custom sizes where finding compatible replacements creates ongoing frustration and expense and where stainless steel’s maximum harsh environment capability extends service life in extreme conditions where galvanized steel’s zinc coating would be compromised and aluminum would experience rapid failure. The enhanced 2″ depth with double the dust-holding capacity of 1″ filters reduces cleaning frequency by approximately half, significantly lowering maintenance labor costs and operational disruptions in harsh environment applications where filter access may be difficult, time-consuming, or require system shutdown during peak production periods. Once you’ve placed your initial custom order, reordering identical stainless steel filters is effortless through your online account, eliminating the need to re-measure or re-specify dimensions for future purchases. The 43% dust arrestance efficiency protects downstream HVAC components while the low 0.10″ pressure drop maintains optimal system efficiency. Simple water-based cleaning every few months—or aggressive caustic cleaning when required—restores peak performance, with Type 304 stainless steel construction supporting repeated cleaning cycles with harsh chemicals throughout the filter’s multi-year service life without corrosion or degradation.
Facility managers, property owners, HVAC contractors, and industrial maintenance professionals choose the HISS20 when standard filters cannot solve their combined dimensional and extreme environment filtration challenges, when operating conditions demand maximum harsh environment capability exceeding galvanized steel’s and aluminum’s limitations, and when reducing maintenance frequency delivers measurable operational value. From maintaining vintage extreme temperature equipment with discontinued filter dimensions to supporting highly corrosive chemical processing environments requiring exceptional corrosion resistance and 900°F temperature capability with extended service intervals, this custom stainless steel mesh filter provides the permanent solution that eliminates filter procurement frustration while delivering premium-grade filtration performance matched to your exact dimensional and extreme environmental requirements with significantly reduced maintenance burden. Invest in a custom-manufactured filter that fits your system perfectly, uses premium Type 304 stainless steel materials engineered for the most demanding harsh environment conditions, provides up to a decade of reliable service in extreme applications, extends cleaning intervals by approximately 100% compared to 1″ filters, and ensures you’ll never struggle to find compatible replacements again. Order your custom HISS20 today and experience the confidence that comes from having a permanent filtration solution precisely matched to every aspect of your unique HVAC system requirements—with premium stainless steel construction delivering the maximum harsh environment capability, extraordinary temperature rating, exceptional corrosion resistance, and extended maintenance intervals your extreme application demands.
Additional information
| Weight | 72.0 oz |
|---|---|
| Frame Material | 304 Stainless Steel |
| GTIN | 00840373527434 |
| MPN | HISS20 |
Custom Mesh Filter, Galvanized Steel, 4 Inch Thick
As low as $0.60 per sq inch
Please provide actual L x W measurements down to the 1/16th inch. Example: “15.25 x 24.1875”. Custom size filters are not returnable so please double check before ordering.
| 1/16 = .0625 | 9/16″ = .5625 |
| 1/8 = .125 | 5/8″ = .625 |
| 3/16 = .1875 | 11/16″ = .6875 |
| 1/4 = .25 | 3/4″ = .75 |
| 5/16 = .3125 | 13/16″ = .8125 |
| 3/8 = .375 | 7/8″ = .875 |
| 7/16 = .4375 | 15/16″ = .9375 |
| 1/2 = .5 | 1″ = 1 |
Description
Product Overview
The HIGS40 Custom 4″ Galvanized Steel Washable Mesh Filter delivers maximum industrial-grade filtration performance for HVAC systems requiring enhanced durability, superior corrosion resistance, elevated temperature capability, and exceptional dust-holding capacity in custom dimensions that off-the-shelf products cannot provide. This made-to-order 4″ nominal depth (3-3/4″ actual) galvanized steel mesh filter combines 24-gauge hot-dip galvanized steel frame construction with robust 9-ply corrugated criss-cross screen wire media, providing 325°F continuous temperature capability and exceptional corrosion resistance for the most demanding humid industrial environments, heavy particulate loading applications, commercial laundries, food processing facilities, manufacturing operations, and applications where standard aluminum construction proves inadequate while requiring maximum dust-holding capacity for extended cleaning intervals. Built to UL 900 Class 1 standards with custom manufacturing to your exact dimensional specifications, this galvanized steel filter ensures reliable pre-filtration performance tailored precisely to your unique HVAC system needs while delivering superior dust-holding capacity that can extend cleaning intervals from monthly cycles to quarterly or even annually in moderate-duty applications—dramatically reducing maintenance frequency and labor costs in demanding industrial conditions.
Engineered with precision-formed 24-gauge galvanized steel frames paired with specialized 9-ply corrugated aluminum screen wire media and 30-gauge galvanized steel face grids, the HIGS40 delivers 43% dust arrestance efficiency in the industry-standard 4″ nominal depth profile with maximum dust-holding capacity. This industrial-grade configuration serves environments requiring enhanced moisture resistance, elevated temperature handling, heavy continuous particulate challenge, and extended cleaning intervals that thinner filters cannot provide—from commercial kitchens operating at elevated ambient temperatures with heavy grease loading to manufacturing facilities with high humidity levels and sustained dust generation where aluminum filters experience premature corrosion and where thinner filters require impractical cleaning frequency. Custom-manufactured to your exact specifications in the USA, each filter ships ready to install with no modifications required, providing permanent filtration for discontinued equipment, non-standard installations, and harsh industrial applications demanding materials that maintain structural integrity and exceptional cleaning interval extension beyond aluminum’s capabilities and beyond thinner filter configurations.
Unlike disposable filters requiring constant replacement—especially problematic for custom sizes with discontinued or non-standard dimensions—this custom galvanized steel washable mesh filter with 9-ply media delivers 5-10 years of continuous service with proper maintenance protocols. The robust hot-dip galvanized construction features precision-mitered corners secured with galvanized pop rivets and 30-gauge galvanized steel face grids ensuring structural integrity through repeated cleaning cycles using standard water-based methods. The 9-ply media configuration with maximum dust-holding capacity extends cleaning intervals dramatically compared to 1″ or 2″ depth filters, reducing maintenance labor costs substantially in applications where filter accessibility challenges make frequent service prohibitively expensive or where heavy particulate loading overwhelms thinner filters. Three strategically placed corner drain holes facilitate complete water removal after washing, preventing moisture retention and accelerating return-to-service time—particularly important in deep filters where water can be trapped in the 3-3/4″ depth. Once you’ve placed your initial custom order, reordering identical replacements is effortless through your online account, ensuring you’ll never struggle to find the right filter size again while maintaining the enhanced durability, temperature capability, and dramatically extended service intervals that galvanized steel with 4″ depth provides.
Facility managers, property owners, and HVAC contractors working with heavy-duty industrial environments, elevated temperature applications, humid conditions with extreme particulate loading, or equipment requiring enhanced corrosion resistance combined with maximum dust-holding capacity rely on custom galvanized steel washable mesh filters with 4″ depth to solve filtration challenges where aluminum construction falls short and where thinner filters create unsustainable maintenance burdens. Whether you’re maintaining commercial kitchen ventilation systems with sustained elevated temperatures and heavy grease accumulation, supporting manufacturing facilities with high humidity and continuous heavy dust generation, servicing food processing plants requiring frequent washdown environments with extended cleaning intervals, or managing commercial laundries operating at sustained elevated temperatures with extreme lint loading, the HIGS40 provides a permanent solution manufactured to your exact specifications. With 325°F continuous temperature rating, superior corrosion resistance compared to aluminum, maximum dust-holding capacity from 9-ply construction for dramatically extended cleaning intervals, low initial airflow resistance, and the ability to maintain peak performance through repeated cleaning cycles, this custom galvanized steel washable mesh filter delivers measurable ROI through eliminated filter replacement costs, extended service life in demanding conditions, substantially reduced maintenance frequency, and the peace of mind that comes from having a reliable long-term filtration solution precisely matched to your system dimensions and operating environment with the longest possible service intervals.
Key Benefits of the HIGS40 Custom 4″ Galvanized Steel Washable Mesh Filter
- Industrial-Grade Galvanized Steel Construction: 24-gauge hot-dip galvanized steel frame with 30-gauge galvanized steel face grids provides enhanced corrosion resistance and structural integrity in humid, corrosive, or elevated temperature environments where aluminum construction degrades prematurely.
- 325°F Continuous Temperature Rating: 50°F higher operating temperature than aluminum construction serves commercial kitchens, manufacturing facilities, and industrial applications with sustained elevated ambient temperatures that exceed aluminum’s 275°F limitation.
- Maximum Dust-Holding Capacity: 9-ply media construction delivers superior dust-holding capacity—significantly exceeding 1″ or 2″ filters—extending cleaning intervals from monthly cycles to quarterly or even annually in moderate applications, dramatically reducing maintenance labor costs.
- Custom Sizing for Any HVAC System: Made-to-order manufacturing accommodates any height and width combination, solving filtration challenges for discontinued equipment, industrial systems, and non-standard installations where off-the-shelf galvanized 4″ filters don’t fit.
- Enhanced Moisture & Humidity Resistance: Hot-dip galvanized coating provides exceptional rust resistance in humid environments, frequent washdown operations, and moisture-rich atmospheres where aluminum oxidation becomes problematic—critical for long-term durability in deep-bed filter applications.
- Effortless Reordering: Once you’ve placed your initial custom order, reordering identical galvanized steel 4″ filters is simple through your online account—no need to re-measure or re-specify dimensions for future purchases.
Technical Specifications
The HIGS40 Custom 4″ Galvanized Steel Washable Mesh Filter represents precision-engineered filtration technology manufactured to your exact dimensional specifications with industrial-grade galvanized steel construction and maximum dust-holding capacity. This industry-standard 4″ nominal depth (3-3/4″ actual) galvanized mesh pre-filter delivers exceptional performance validated through rigorous UL 900 Class 1 testing, ensuring reliable operation in continuous high-temperature and corrosive environments up to 325°F. Every custom filter is built with the same industrial-grade construction standards as our stock HIG Series products, providing the enhanced durability, corrosion resistance, and dramatically extended cleaning intervals you expect from hot-dip galvanized steel construction with 9-ply media and dimensions tailored precisely to your unique HVAC system requirements.
Manufactured in the USA using premium 24-gauge galvanized steel framing paired with 9-ply corrugated criss-cross aluminum screen wire media and 30-gauge galvanized steel face grids, this custom washable mesh filter meets the stringent requirements of industrial and commercial HVAC applications requiring non-standard filter dimensions with enhanced environmental resistance and maximum dust-holding capacity. The 4″ nominal (3-3/4″ actual) depth profile ensures compatibility with the vast majority of HVAC filter tracks designed for 4-inch filters while the 43% dust arrestance efficiency protects downstream equipment from premature loading. With maximum dust-holding capacity from 9-ply construction—dramatically exceeding 5-ply (1″) and 7-ply (2″) configurations—this custom galvanized steel filter extends cleaning intervals to unprecedented levels and reduces maintenance frequency substantially in applications where finding replacement filters has historically been challenging and where material durability, environmental resistance, and extended service intervals directly impact operational costs.
| Specifications: | Details: |
|---|---|
| Model Number | HIGS40 (Custom 4″ Galvanized Steel) |
| Filter Depth | 4″ nominal (3-3/4″ actual depth) |
| Height & Width | Custom dimensions manufactured to your exact specifications |
| Dimensional Tolerance | ±1/8″ on height and width, ±1/16″ on depth |
| Frame Material | 24-gauge hot-dip galvanized steel |
| Filter Media | 9-ply corrugated criss-cross aluminum screen wire mesh |
| Face Grid Material | 30-gauge galvanized steel |
| Frame Construction | Precision-mitered corners, galvanized pop rivets |
| Drainage | 3 corner drain holes for complete water removal after washing |
| Maximum Operating Temperature | 325°F continuous (UL 900 Class 1 certified) |
| Dust Arrestance Efficiency | 43% average at rated airflow (350 FPM) |
| Dust Holding Capacity | Superior capacity from 9-ply construction (significantly exceeds 1″ and 2″ filters) |
| Rated Airflow | 350 FPM (feet per minute) |
| Recommended Airflow Range | 300-500 FPM face velocity |
| Initial Pressure Drop | 0.12″ w.g. @ 350 FPM (clean filter) |
| Recommended Final Resistance | 0.50″ w.g. (water gauge) before cleaning |
| Weight | Varies by custom dimensions (heavier than aluminum, lighter than stainless) |
| Washability | Repeated cleaning cycles with water-based methods, detergents, or pressure washers |
| Service Life | 5-10 years with proper maintenance protocols |
| Compliance & Certifications | UL 900 Class 1, ASTM E 2931 (washable filter standard) |
| Country of Origin | Made in USA |
Industrial & Specialized Applications
The HIGS40 Custom 4″ Galvanized Steel Washable Mesh Filter solves critical filtration challenges across industrial and commercial applications where enhanced corrosion resistance, elevated temperature capability, maximum dust-holding capacity, and structural durability exceed aluminum’s limitations while custom dimensions accommodate unique HVAC equipment requirements. From humid manufacturing environments with extreme heavy particulate loading to commercial kitchens operating at sustained elevated temperatures with heavy grease accumulation requiring extended cleaning intervals, this galvanized steel solution with 9-ply deep-bed construction ensures reliable pre-filtration when standard materials, standard sizes, and thinner filter depths cannot meet your system’s combined dimensional, environmental, and maintenance demands.
Commercial Kitchen & Food Service Equipment
Commercial kitchens, restaurants, and food processing facilities operate HVAC systems exposed to elevated ambient temperatures, heavy grease-laden airstreams, high humidity, and frequent washdown protocols that accelerate aluminum corrosion while extreme particulate loading demands maximum dust-holding capacity. The HIGS40’s 325°F continuous temperature rating and superior galvanized steel corrosion resistance combined with 9-ply media construction serve ventilation systems for commercial ovens, dishwasher hood exhaust, prep area ventilation, and walk-in cooler/freezer condensing units where temperatures regularly exceed aluminum’s 275°F capability, where moisture exposure demands enhanced rust protection, and where heavy grease and particulate accumulation would overwhelm thinner filters with impractical monthly or even weekly cleaning requirements. Restaurant chains maintaining older HVAC equipment with discontinued filter dimensions requiring dramatically extended service intervals, institutional kitchens in schools and hospitals with non-standard ventilation configurations and severely limited maintenance access, and food processing plants requiring custom-sized pre-filtration for specialized equipment with extreme particulate loading depend on galvanized steel construction with 9-ply media to maintain filtration performance throughout years of demanding service while keeping cleaning intervals to manageable quarterly or semi-annual schedules. The permanent washable construction means once you’ve established your custom dimensions and experienced galvanized steel’s superior durability combined with dramatically extended cleaning intervals in your specific application, reordering identical replacements through your online account ensures consistent filtration performance without the frustration of searching for compatible custom-sized alternatives with adequate depth.
Manufacturing & Industrial Facilities
Industrial manufacturing environments—including textile mills, printing operations, chemical processing plants, woodworking facilities, metalworking operations, and general manufacturing facilities—subject HVAC filtration systems to elevated temperatures, high humidity levels, chemical vapor exposure, and extreme continuous heavy particulate loading that compromise aluminum filter longevity while overwhelming thinner filters with unmanageable cleaning frequency demands. The HIGS40’s hot-dip galvanized steel construction provides exceptional corrosion resistance in humid industrial atmospheres while the 325°F temperature rating protects against heat degradation and the 9-ply media with maximum dust-holding capacity extends cleaning intervals from weekly or monthly (with thinner filters) to quarterly or even annually in moderate-duty applications. Plastics manufacturing facilities with thermoforming operations generating sustained elevated temperatures and heavy airborne particulate, commercial laundries operating with continuous steam exposure and extreme lint loading requiring extended service intervals, printing plants with solvent vapor atmospheres and continuous paper dust accumulation, woodworking facilities with sawdust and wood particulate challenges, and automotive shops with paint booth ventilation systems requiring maximum cleaning interval extension rely on galvanized steel filters with 9-ply media when equipment dimensions require custom manufacturing and when operating conditions demand materials and dust-holding capacity exceeding aluminum’s environmental and maintenance limitations. The 5-10 year service life with proper maintenance delivers exceptional ROI in industrial applications where filter accessibility challenges make frequent replacements prohibitively costly and where galvanized steel’s enhanced durability combined with dramatically extended cleaning intervals directly reduces maintenance labor and system downtime substantially.
Humid & Moisture-Rich Environments with Extreme Particulate
Applications involving sustained high humidity, frequent condensation, extreme heavy dust loading, or regular washdown procedures benefit from galvanized steel’s superior rust resistance combined with 9-ply media’s maximum cleaning interval extension compared to aluminum construction with thinner media packs. Indoor swimming pool dehumidification systems with heavy lint and debris accumulation, greenhouse climate control equipment with pollen and organic matter loading, car wash facility ventilation with moisture exposure and heavy airborne contamination, commercial dishwashing hood exhaust with grease and steam, coastal facilities exposed to salt-laden air with heavy industrial dust, and cement plants with extreme particulate challenge experience accelerated aluminum oxidation that galvanized steel’s protective zinc coating effectively prevents while 9-ply capacity extends service intervals to manageable levels despite extreme loading. The HIGS40 serves these moisture-rich applications with extreme heavy particulate loading with custom dimensions matching discontinued equipment specifications while providing corrosion resistance that extends service life significantly beyond aluminum alternatives and dust-holding capacity that prevents the weekly or bi-weekly cleaning cycles that would be required with thinner filters. Facility managers maintaining aquatic centers with older HVAC systems using non-standard filter sizes and extreme lint loading, greenhouse operators requiring custom filtration for European-manufactured climate control equipment with heavy pollen accumulation, bulk material handling facilities with extreme dust generation, and car wash operations supporting legacy ventilation systems with moisture and heavy contamination depend on galvanized steel construction with 9-ply media to maintain structural integrity and manageable cleaning intervals through years of moisture exposure and extreme particulate challenge. The washable design means repeated cleaning cycles—even with aggressive detergents required in these environments—don’t compromise the galvanized coating’s protective properties, ensuring the filter maintains both dimensional accuracy and corrosion resistance throughout its service life while the maximum dust-holding capacity keeps maintenance intervals practical even in extreme conditions.
Discontinued Equipment & Legacy Industrial Systems
Industrial facilities maintaining older equipment face compounded challenges when original manufacturers discontinue filter production AND when operating environments require galvanized steel’s enhanced durability rather than standard aluminum construction AND when heavy particulate loading demands maximum dust-holding capacity to prevent unmanageable cleaning frequency. Vintage commercial rooftop units serving manufacturing facilities with extreme dust loading, legacy industrial ventilation systems with non-standard dimensions and severely limited maintenance access, European-manufactured industrial HVAC equipment using metric sizing with elevated temperature exposure and heavy particulate challenge, and specialty industrial applications with custom filter requirements and extreme particulate loading benefit from the HIGS40’s combination of made-to-order dimensional flexibility, industrial-grade galvanized steel construction, and 9-ply media for maximum service interval extension. The custom manufacturing process ensures exact dimensional match to original specifications while galvanized steel provides the corrosion resistance and temperature capability required by industrial operating conditions and the 9-ply maximum dust-holding capacity reduces maintenance frequency from unsustainable weekly or monthly intervals to practical quarterly or annual schedules. Once you’ve specified your custom dimensions and confirmed galvanized steel performance with dramatically extended cleaning intervals in your specific environment, future reorders through your online account maintain consistent filtration capability without the perpetual frustration of searching for compatible custom-sized industrial-grade replacement filters with adequate depth and dust-holding capacity.
Material Selection Guide
The HIGS40 features industrial-grade galvanized steel construction with 9-ply media specifically engineered for applications requiring enhanced corrosion resistance, elevated temperature capability, and maximum dust-holding capacity beyond aluminum’s limitations. Understanding when galvanized steel with 4″ depth provides optimal value—compared to cost-effective aluminum or premium stainless steel, and compared to thinner 1″ or 2″ depth filters—ensures maximum service life, performance, cleaning interval extension, and return on investment based on your specific operating environment and maintenance requirements.
HIG: Galvanized Steel Construction (Industrial Grade – 4″ Depth)
The galvanized steel construction features 24-gauge hot-dip galvanized steel frame construction with 9-ply aluminum screen wire media and 30-gauge galvanized steel face grids, delivering enhanced corrosion resistance, elevated 325°F temperature capability, and maximum dust-holding capacity at moderate cost increase over aluminum. The protective zinc coating applied through hot-dip galvanizing process provides exceptional rust resistance in humid environments, moisture-rich atmospheres, and applications involving frequent washdown or cleaning protocols, while the 9-ply media configuration extends cleaning intervals dramatically—potentially from monthly cycles (with 1″ filters) to quarterly or even annual intervals in moderate-duty applications. Choose galvanized steel with 4″ depth when your application involves moderately elevated temperatures (275-325°F), humid environments requiring enhanced rust resistance, industrial settings where aluminum might corrode prematurely AND when extreme heavy particulate loading demands maximum dust-holding capacity to prevent unmanageable cleaning frequency, or when the 50°F higher temperature rating combined with maximum dust-holding capacity provides necessary operational advantages over aluminum construction and thinner filter depths. Galvanized filters with 4″ depth excel in commercial laundries with extreme lint loading, printing facilities with continuous heavy paper dust, food processing plants with heavy grease and organic matter accumulation, humid industrial environments with sustained extreme particulate challenge, manufacturing operations requiring maximum maintenance interval extension, commercial kitchens with elevated temperatures and heavy grease loading, woodworking facilities with sawdust challenges, cement plants with extreme particulate, and applications where aluminum’s environmental limitations OR inadequate dust-holding capacity from thinner depths compromise service life or create prohibitive maintenance frequency. The 5-10 year service life matches aluminum and stainless steel duration but delivers this longevity in significantly more demanding conditions while the maximum dust-holding capacity maintains practical cleaning intervals even in extreme applications—making galvanized steel with 4″ depth the optimal value choice for harsh environments with extreme heavy particulate loading where aluminum fails prematurely or where thinner filters require impractical maintenance frequency.
HIA: Aluminum Construction (Standard Grade – 4″ Depth)
Aluminum construction with .030″ thick aluminum alloy frames and 9-ply media provides cost-effective filtration solution for standard industrial and commercial HVAC applications with normal indoor temperatures, dry environments, and heavy particulate loading where extended cleaning intervals are priority. With 275°F continuous temperature rating and excellent corrosion resistance in non-humid conditions, aluminum with 9-ply maximum capacity serves many HVAC environments at lowest initial cost where environmental conditions permit. Consider upgrading to galvanized steel (HIGS40) when your application involves temperatures approaching or exceeding 275°F, sustained high humidity levels, frequent moisture exposure, extreme continuous particulate loading requiring maximum cleaning interval extension, or when premature aluminum corrosion has shortened filter service life in your specific environment. The moderate cost increase for galvanized construction delivers substantial service life extension in demanding conditions and maintains practical cleaning intervals even in extreme-particulate applications—providing better long-term value than repeatedly replacing corroded aluminum filters or performing impractical cleaning cycles on aluminum filters with adequate depth but insufficient environmental protection.
HIS: 304 Stainless Steel Construction (Premium Grade – 4″ Depth)
304 stainless steel construction with 24-gauge stainless steel frames, 9-ply stainless media, and all-stainless face grids provides maximum corrosion resistance and exceptional 900°F continuous temperature rating for the most extreme applications. Choose stainless steel over galvanized when your application involves extreme temperatures exceeding 325°F (foundries, commercial bakeries, industrial drying operations), highly corrosive chemical environments beyond galvanized steel’s capabilities, or when maximum service life in extraordinarily harsh conditions justifies premium initial investment. For most industrial applications with elevated temperatures (275-325°F), humid or corrosive conditions, and extreme heavy particulate loading, galvanized steel (HIGS40) with 9-ply media provides optimal balance of enhanced durability, maximum cleaning interval extension, and cost-effectiveness—reserving stainless steel for truly extreme environments where galvanized steel’s 325°F rating or corrosion resistance proves inadequate. Note that service life for stainless steel is 5-10 years—the same as galvanized steel and aluminum—with stainless steel’s advantage being its ability to achieve this service life in extremely harsh environments rather than extended longevity in standard conditions. The maximum dust-holding capacity from 9-ply construction is identical across all three materials with 4″ depth.
1″/2″/4″ Depth Comparison
When deciding between HIGS10 (1″ nominal, 5-ply, 68 g/sq ft), HIGS20 (2″ nominal, 7-ply, 97 g/sq ft), and HIGS40 (4″ nominal, 9-ply, maximum capacity), consider both space constraints and maintenance interval requirements. Choose 1″ depth (HIGS10) when filter housing depth is limited to 1″ nominal or when light to moderate dust loading allows acceptable cleaning frequency. Choose 2″ depth (HIGS20) when housing accommodates 2″ nominal AND when moderate to heavy particulate loading justifies extended cleaning intervals. Choose 4″ depth (HIGS40) when filter housing accommodates 4″ nominal depth AND when extreme heavy particulate loading, severely limited maintenance access, or substantial labor cost considerations justify the maximum cleaning interval extension provided by 9-ply construction. In applications where all depths physically fit, the 4″ galvanized filter typically provides best long-term value in industrial environments with extreme dust loading by dramatically reducing maintenance frequency to practical levels—potentially extending intervals from monthly (with 1″ filters) to quarterly or annually despite higher initial cost. All depths provide identical 325°F temperature rating, corrosion resistance, and 5-10 year service life with proper maintenance.
Construction Features
The HIGS40 Custom 4″ Galvanized Steel Washable Mesh Filter is engineered with precision manufacturing techniques, industrial-grade materials, and maximum media construction that ensure every custom-sized unit meets rigorous quality standards for enhanced durability, corrosion resistance, and dramatically extended cleaning intervals. UL 900 Class 1 certification validates continuous operation capability at 325°F, while Made in USA construction guarantees dimensional accuracy and structural integrity throughout the filter’s 5-10 year service life in demanding industrial environments with extreme heavy particulate loading.
Hot-Dip Galvanized Steel Deep Frame Construction
The foundation of this custom filter begins with a precision-formed 24-gauge steel deep frame subjected to hot-dip galvanizing process, where the steel is immersed in molten zinc to create a metallurgically bonded protective coating. This galvanizing process provides superior corrosion resistance compared to aluminum’s natural oxide layer, preventing rust formation in humid environments, moisture-rich atmospheres, and applications involving frequent wet cleaning cycles. The 24-gauge thickness delivers excellent structural rigidity while the hot-dip zinc coating ensures the frame maintains dimensional stability and corrosion resistance throughout repeated thermal cycling between ambient and elevated operating temperatures up to 325°F. The 4″ nominal (3-3/4″ actual) deep frame depth provides substantial frame structure compared to thinner filters, accommodating the robust 9-ply media pack while maintaining proper airflow transition and providing reinforced corners to handle the additional weight and stress from deep-bed filter construction. Professional-grade mitered corners secured with galvanized pop rivets ensure the frame maintains perfect dimensional accuracy to your custom specifications throughout repeated cleaning cycles and years of service in demanding conditions with extreme heavy particulate loading. Each custom frame is manufactured to your exact height and width requirements with ±1/8″ tolerance, ensuring precise fit without gaps or binding in your HVAC system’s filter tracks while the galvanized construction prevents the corrosion-induced dimensional changes that can compromise aluminum filter fit over time. The deep frame design is engineered specifically to support the 9-ply media structure throughout extended service intervals.
Maximum 9-Ply Media Pack
The filtration media consists of nine layers of corrugated aluminum screen wire arranged in a precision criss-cross weave pattern specifically engineered for 4″ nominal depth applications. This 9-ply configuration achieves 43% dust arrestance efficiency while delivering maximum dust-holding capacity—dramatically exceeding 5-ply (1″) and 7-ply (2″) configurations—substantially extending cleaning intervals from monthly cycles to quarterly or even annual intervals in moderate-duty applications and maintaining practical intervals even in extreme-particulate industrial environments. The aluminum media provides excellent particulate capture with lightweight construction while the galvanized steel frame and face grids deliver the enhanced structural durability and temperature capability required for industrial applications. Each layer features expanded mesh construction with carefully engineered strand spacing that captures large particulates through multiple interception stages. The nine-layer corrugated structure provides maximum surface area within the 4″ nominal depth while the criss-cross weave pattern ensures uniform particle distribution across the entire media pack. This engineering approach delivers effective pre-filtration performance with manageable pressure drop, protecting downstream HVAC components without overburdening system blowers—with galvanized steel construction ensuring the frame and face grids maintain structural integrity even when industrial operating conditions would compromise aluminum alternatives, and with maximum dust-holding capacity ensuring cleaning intervals remain practical despite extreme heavy particulate loading that would overwhelm thinner filter depths.
Corner Drain System
Three strategically positioned corner drain holes facilitate rapid water evacuation following cleaning operations, with typical air-drying times of 60-120 minutes depending on ambient conditions due to the increased depth of the 9-ply media pack. The open mesh construction and robust galvanized steel frame design enable complete water drainage without trapped moisture in corner joints or frame channels—particularly important in 4″ depth filters where water can be trapped in the 3-3/4″ depth. This drainage system prevents water pooling that could lead to odor development while the hot-dip galvanized coating ensures the frame resists corrosion even with repeated wet-dry cycles throughout the filter’s multi-year service life. The galvanized steel construction naturally resists rust formation in humid environments and moisture-rich applications, maintaining structural integrity and filtration performance through thousands of operational hours and repeated cleaning cycles—delivering consistent dimensional accuracy and reliable filtration in conditions where aluminum frames would experience oxidation and potential warping. The enhanced 3-3/4″ actual depth accommodates the 9-ply media pack while the drain system ensures complete moisture removal from the deep filter structure regardless of filter depth.
Galvanized Steel Face Grid Protection
Both upstream and downstream faces incorporate 30-gauge galvanized steel protective grids that shield the 9-ply media layers from physical damage during handling, installation, and operation. These galvanized steel face grids distribute incoming airflow uniformly across the entire filter surface, preventing concentrated jet streams that could damage the media structure while maintaining the manageable pressure drop characteristic of 4″ nominal depth filtration with 9-ply media. The grid construction provides impact resistance against accidental contact during filter changeouts while the hot-dip galvanized coating ensures the face grids resist corrosion in humid or corrosive atmospheres where aluminum grids might oxidize. This protective layer ensures the custom-manufactured filter maintains its structural integrity and filtration performance throughout thousands of operational hours and repeated cleaning cycles in extreme heavy-particulate environments, with galvanized steel construction delivering enhanced durability compared to aluminum in demanding industrial and commercial applications with elevated temperatures and continuous extreme dust loading. The face grids are critical for protecting the investment in 9-ply deep-bed construction throughout extended service intervals.
Maintenance & Cleaning Protocol
The HIGS40 Custom 4″ Galvanized Steel Washable Mesh Filter requires minimal maintenance while delivering 5-10 years of reliable service in demanding industrial and commercial environments. Unlike disposable filters that create ongoing frustration finding compatible replacements for custom sizes, this industrial-grade galvanized steel mesh filter with 9-ply media supports repeated cleaning cycles using simple water-based methods without expensive cleaning agents or replacement costs—with hot-dip galvanized construction ensuring corrosion resistance throughout years of wet cleaning cycles and with maximum dust-holding capacity dramatically extending cleaning intervals to quarterly or even annual schedules in moderate-duty applications, substantially reducing maintenance labor costs compared to thinner filters.
Cleaning Methods
Four effective cleaning methods accommodate different facility capabilities and contamination levels. Garden hose cleaning provides the simplest approach, using high-pressure nozzle settings to spray both sides of the 9-ply media until water runs clear—typically sufficient for most commercial and light industrial applications, though the 4″ depth requires thorough rinsing of both faces to ensure complete cleaning of the deep media pack and may require 2-3 times longer cleaning time than thinner filters. Sink or tub soaking works well for moderate to heavy contamination typical after extended service intervals, submerging the filter in warm soapy water for 30-60 minutes before rinsing thoroughly (galvanized steel benefits from mild detergent and tolerates more aggressive cleaning agents than aluminum without corrosion concerns, while the 9-ply media requires extended soak time to allow deep penetration through all layers). Commercial dishwashers or automated filter cleaning systems offer hands-free cleaning for facilities with industrial equipment sized for deep filters, with galvanized construction tolerating standard commercial dishwasher temperatures and detergents without degradation—ensure cleaning system accommodates the 4″ depth dimension. Pressure washing delivers fast results for heavier contamination typical in extreme-particulate industrial applications, using 1000-1500 PSI with warm water—galvanized steel’s robust construction tolerates higher pressure than aluminum while the protective zinc coating prevents rust formation even with repeated high-pressure wet cleaning, and the 9-ply media’s enhanced thickness requires thorough pressure washing from both sides to dislodge accumulated particulate from the deep media pack structure. The hot-dip galvanized frame and face grids withstand repeated washing without corrosion or degradation, maintaining structural integrity throughout the filter’s service life while operating continuously at 325°F temperature rating. Allow 60-120 minutes for complete air drying of the deep 9-ply structure before reinstallation.
Recommended Cleaning Frequency
Cleaning intervals depend on operating environment and particulate loading rates, with the HIGS40’s maximum 9-ply dust-holding capacity extending intervals dramatically compared to 68 g/sq ft (1″) or 97 g/sq ft (2″) thinner filters. Light dust environments such as standard commercial applications require cleaning every 6-12 months—potentially 3-4 times longer intervals than 1″ filters in equivalent conditions. Moderate industrial applications including manufacturing facilities and commercial operations benefit from cleaning schedules every 3-6 months—extended from monthly or bi-monthly intervals typical with thinner filters. High-particulate industrial environments with continuous extreme heavy dust generation may need quarterly to semi-annual cleaning—dramatically extended from weekly or monthly intervals required with thinner filters. Visual inspection provides the most reliable cleaning indicator—schedule cleaning when the 9-ply screen wire media appears visibly loaded with dust or when system airflow seems reduced. Monitor pressure drop across the filter if instrumentation is available, cleaning when resistance reaches 0.50″ w.g. to maintain energy-efficient system operation. In humid environments or applications involving frequent moisture exposure, inspect the galvanized steel frame periodically to verify the protective zinc coating maintains its integrity—though properly maintained galvanized filters typically show no corrosion throughout their 5-10 year service life. The maximum dust-holding capacity of the 4″ depth dramatically reduces maintenance labor costs compared to 1″ or 2″ filters in equivalent extreme-particulate applications, making the HIGS40 particularly cost-effective in industrial environments where filter accessibility challenges make frequent cleaning prohibitively expensive or where extreme particulate loading would require impractical weekly or monthly cleaning with thinner filters.
Handling Considerations for Galvanized Steel Deep Filter Construction
Galvanized steel filters with 4″ depth provide enhanced durability with substantial weight increase compared to aluminum construction and significantly increased weight compared to 1″ or 2″ depth, tolerating somewhat more aggressive handling and cleaning pressure while requiring proper support during maintenance. Support all custom sizes from underneath during cleaning and installation to prevent frame stress—mandatory for the increased weight of 4″ depth filters. The 24-gauge galvanized steel frame construction with 3-3/4″ actual depth provides excellent structural rigidity, though the combination of galvanized steel material and 4″ depth with 9-ply media creates substantially heavier filters than aluminum or thinner alternatives—two-person handling is strongly recommended for most custom sizes for safe installation and removal. The hot-dip galvanized coating tolerates repeated wet-dry cycles and mechanical cleaning without degradation—maintaining corrosion resistance and dimensional stability throughout years of service in demanding industrial and commercial applications. Avoid using extremely abrasive cleaning tools that might damage the protective zinc coating, though normal pressure washing, detergent cleaning, and standard handling poses no risk to properly galvanized construction. The enhanced media depth requires thorough cleaning from both sides to ensure complete particulate removal from the 9-ply structure—budget additional time for deep filter cleaning compared to thinner configurations.
Installation
Installing the HIGS40 Custom 4″ Galvanized Steel Washable Mesh Filter follows the same straightforward procedures as standard filters, with attention to proper orientation, secure seating, depth clearance, and weight handling to ensure optimal performance from your custom-manufactured industrial-grade filtration solution with maximum dust-holding capacity.
Pre-Installation Verification
Before installing your custom galvanized steel 4″ filter, verify the dimensions match your original specifications and that your HVAC system is completely shut down with power disconnected. Inspect the filter housing interior for accumulated dust, debris, or damage that could compromise the seal. The custom-manufactured filter should fit your housing precisely with minimal clearance—if excessive gaps exist, verify you’re installing in the correct location and orientation. Confirm the filter housing accommodates the 4″ nominal (3-3/4″ actual) deep depth—measure the housing depth to ensure adequate clearance for this thick filter compared to 1″ or 2″ alternatives you may have previously used. Note that 4″ filters are substantially heavier than thinner configurations, particularly in galvanized steel construction—ensure safe handling procedures and two-person installation capability for larger custom sizes. Check the condition of existing gaskets or sealing surfaces, replacing worn gaskets (typically 1/2″ to 3/4″ thick for 4″ filters) before installing your new permanent filter. Clean the filter housing interior thoroughly with a vacuum or damp cloth to ensure optimal sealing surfaces. Locate the airflow direction arrow marked on your new custom filter frame, ensuring you understand proper orientation before installation. Note the galvanized steel construction and 4″ depth for documentation in your maintenance records, particularly in industrial environments where tracking filter material specifications and media depth supports compliance and quality management protocols and where the dramatically extended cleaning intervals enabled by 9-ply construction should be documented for maintenance planning.
Installation Steps
With the HVAC system powered off and locked out, open the filter access door or remove the access panel. Carefully remove any existing filter, noting its orientation and airflow direction. Inspect your new HIGS40 custom galvanized steel 4″ filter and locate the airflow direction arrow clearly marked on the frame. The 4″ nominal (3-3/4″ actual) depth creates substantial handling weight compared to thinner filters, and the galvanized steel construction creates heavier weight than aluminum—two-person installation is strongly recommended for safe handling of these deep, heavy filters in most custom sizes. Insert the filter into the housing with the airflow arrow pointing in the correct direction of air movement through your system. Press the filter firmly into place, ensuring all edges seat properly against the gasket or housing walls without forcing—the 4″ depth requires verification that the filter seats completely within the housing depth without interference with access doors or adjacent components. The robust 24-gauge galvanized steel deep frame construction prevents flexing during installation while the custom dimensions create proper fit without excessive gaps around the perimeter. Verify the increased depth and weight don’t interfere with access doors, adjacent components, or housing closure—deep filters may require modifications to access panel clearances in some installations. Secure the access door or panel, restore power, and restart system operation.
Post-Installation Verification
After system restart, listen carefully for any unusual sounds such as air whistling or rattling that might indicate improper seating or depth interference. Verify proper airflow by checking that air velocity at supply registers matches expected performance levels. The slightly higher pressure drop of the 4″ nominal filter with 9-ply media (0.12″ w.g. vs. 0.08″ w.g. for 1″ filters or 0.10″ w.g. for 2″ filters) means system performance should still maintain acceptable levels while providing dramatically extended cleaning intervals that more than offset the modest pressure increase through reduced maintenance frequency. Document the installation date, custom dimensions, galvanized steel construction specification, and 4″ depth in your maintenance records for future reordering through your online account. The 43% dust arrestance efficiency with maximum 9-ply dust-holding capacity begins immediately protecting downstream HVAC components from large particulates and debris while the exceptional capacity delays the first cleaning interval dramatically compared to thinner filters—potentially extending first cleaning from monthly (with 1″ filters) to quarterly or even annually depending on particulate loading rates. Establish a regular inspection schedule based on your specific environmental conditions to monitor dust accumulation and maintain optimal system performance throughout the filter’s 5-10 year service life. In humid or corrosive industrial environments, the galvanized steel construction provides peace of mind that the filter will maintain structural integrity and dimensional accuracy throughout years of demanding service where aluminum alternatives might experience premature degradation, while the maximum dust-holding capacity ensures cleaning intervals remain practical despite extreme heavy particulate loading that would create unsustainable maintenance burdens with thinner filter depths.
Complementary Products
The HIGS40 Custom 4″ Galvanized Steel Washable Mesh Filter excels as a pre-filtration stage with maximum cleaning interval extension, but complete HVAC protection in multi-stage industrial systems may require complementary secondary filtration products. By combining this custom galvanized steel mesh pre-filter with specialized secondary filters, you achieve optimal air quality while protecting expensive downstream filtration equipment in demanding industrial environments with extreme heavy particulate loading.
The 43% dust arrestance efficiency with maximum 9-ply dust-holding capacity of this custom 4″ galvanized steel mesh pre-filter makes it the ideal first stage for industrial filtration systems requiring custom dimensions where standard filters cannot accommodate unique equipment specifications and where operating conditions demand galvanized steel’s enhanced durability with dramatically extended cleaning intervals.
Alternative Material Options (Custom Dimensions – 4″ Depth)
For systems requiring alternative materials with same maximum depth:
• Custom 4″ Stainless Steel Filter (HISS40) – Upgrade to stainless steel for applications where temperatures exceed 325°F or extreme corrosion resistance required beyond galvanized capabilities.
• Custom 4″ Aluminum Filter (HIAS40) – Cost-effective aluminum option with same 9-ply maximum capacity for applications where environmental conditions permit.
• Custom 4″ Aluminum Mist Eliminator (HMAS40) – Specialized 4″ depth mist eliminator for applications with moisture or oil-laden air requiring maximum depth capacity.
Custom Thinner Galvanized Steel Options
For multi-stage systems with galvanized steel throughout:
• Custom 2″ Galvanized Steel Secondary Filter (HIGS20) – Add custom 2″ galvanized secondary stage after 4″ pre-filtration for enhanced particle capture with consistent material properties.
• Custom 1″ Galvanized Steel Tertiary Filter (HIGS10) – Add custom 1″ galvanized tertiary stage for multi-stage industrial applications with space constraints in downstream positions.
Standard Galvanized Steel Filters (If Dimensions Match)
If your secondary stage uses standard dimensions:
• HIG401620 – 16x20x4 Galvanized Steel Filter – Standard 4-inch galvanized steel filter for maximum secondary stage dust-holding capacity.
• HIG401224 – 12x24x4 Galvanized Steel Filter – Stock 4-inch galvanized steel filter for immediate availability with 9-ply media.
• HIG201620 – 16x20x2 Galvanized Steel Filter – Standard 2-inch galvanized steel secondary filtration with extended cleaning intervals.
Frequently Asked Questions
Why choose 4″ galvanized steel over thinner depths or aluminum?
Choose the HIGS40 (4″ galvanized steel) over alternatives when you need the combined benefits of industrial-grade corrosion resistance AND maximum cleaning interval extension from exceptional dust-holding capacity. The 4″ depth with 9-ply media provides maximum capacity—dramatically exceeding 1″ filters (5-ply, 68 g/sq ft) and 2″ filters (7-ply, 97 g/sq ft)—potentially extending cleaning intervals from monthly cycles to quarterly or even annually in moderate applications. The galvanized steel construction adds 325°F temperature rating (50°F higher than aluminum) and superior rust resistance. Choose 4″ galvanized steel when your application involves elevated temperatures approaching or exceeding aluminum’s 275°F limit, humid environments where aluminum corrodes, AND extreme heavy particulate loading where thinner filter cleaning frequency becomes impractical or impossible. The combination delivers both environmental durability and dramatically extended maintenance intervals—providing exceptional long-term value by eliminating repeated aluminum filter replacement and minimizing maintenance labor through maximum cleaning interval extension.
How much longer between cleanings with 4″ versus 1″ or 2″ filters?
The HIGS40’s 9-ply maximum capacity versus HIGS10’s 5-ply (68 g/sq ft) or HIGS20’s 7-ply (97 g/sq ft) extends intervals dramatically. Compared to 1″ filters: if you currently clean monthly, the 4″ filter might extend to quarterly or even semi-annually—potentially 3-6 times longer. Compared to 2″ filters: if you currently clean every 6-8 weeks, the 4″ filter might extend to quarterly or beyond—roughly 2-3 times longer. In extreme-particulate environments requiring weekly cleaning with 1″ filters, the 4″ filter might extend to monthly or quarterly intervals—transforming unsustainable maintenance burdens into practical schedules. Monitor your first cleaning cycle with the new 4″ filter to establish optimal interval for your application, but expect dramatic interval extension that substantially reduces maintenance labor costs.
Will the 4″ filter fit in my current 1″ or 2″ filter housing?
No. The HIGS40 requires a filter housing designed for 4″ nominal (3-3/4″ actual) depth filters. The 4″ filter is substantially deeper than 1″ (7/8″ actual) or 2″ (1-3/4″ actual) filters—nearly 3 inches deeper than 1″ and 2 inches deeper than 2″. Before ordering the HIGS40, measure your filter housing depth to confirm it accommodates 4″ nominal filters. If your housing only accepts 1″ depth, order the HIGS10 instead. If your housing only accepts 2″ depth, order the HIGS20 instead. Only upgrade to 4″ depth when your housing physically accommodates it—but when housing permits, the 4″ depth provides exceptional value through dramatically reduced maintenance frequency.
Does galvanized steel affect filtration efficiency or capacity?
No, material selection does not affect filtration performance or dust-holding capacity. The HIGS40 galvanized steel filter provides identical 43% dust arrestance efficiency and maximum 9-ply dust-holding capacity as aluminum (HIAS40) or stainless steel (HISS40) construction in 4″ depth. The 9-ply media configuration delivers the same particle capture performance and maximum capacity regardless of frame material. Material selection affects temperature rating (aluminum 275°F vs. galvanized 325°F vs. stainless 900°F), corrosion resistance, weight, and cost—but not filtration efficiency or dust-holding capacity. Choose galvanized steel for its enhanced environmental durability and temperature capability while achieving the same filtration performance and maximum cleaning interval benefits as other materials.
Is galvanized steel 4″ filter washable and reusable?
Yes, the HIGS40 galvanized steel filter is designed for repeated washing and reuse throughout its 5-10 year service life—identical to aluminum and stainless steel service life expectations. The hot-dip galvanized coating withstands repeated cleaning cycles using water-based methods, detergents, pressure washers, or commercial dishwashers without corrosion or degradation. Galvanized steel’s superior rust resistance makes it more tolerant of aggressive cleaning protocols compared to aluminum—maintaining structural integrity through years of regular washing. The 9-ply media requires thorough rinsing from both sides during cleaning (allow 60-120 minutes for complete drying) to ensure complete particulate removal from the deep media structure, but you’ll perform these cleanings far less frequently than with thinner filters—dramatically reducing cumulative maintenance labor over the filter’s service life.
Can I order aluminum, galvanized, or stainless in the same custom 4″ dimensions?
Yes, absolutely. Once you’ve specified your custom dimensions for the HIGS40 galvanized steel 4″ filter, you can order the same size in aluminum (HIAS40) for cost-effective applications or stainless steel (HISS40) for extreme conditions. Many facility managers maintain inventory in multiple materials for different zones—aluminum for standard areas, galvanized steel for humid or elevated temperature zones with extreme particulate, stainless steel for extreme applications. Your custom dimensions are saved in your account for easy reordering. All three materials provide identical maximum 9-ply dust-holding capacity and 43% filtration efficiency in 4″ depth—material choice is based on environmental requirements, not filtration performance.
How long does custom 4″ galvanized steel filter manufacturing take?
Custom galvanized steel 4″ filter manufacturing typically requires 5-10 business days from order confirmation to shipment, though production schedules may vary based on current order volume. Galvanized steel production may add 1-2 days to lead time compared to aluminum due to the hot-dip galvanizing process. The 4″ depth does not significantly affect production time compared to other depths. Rush production is available for critical applications. We recommend ordering before your existing filter reaches end-of-service—though with the dramatically extended cleaning intervals enabled by 4″ depth, you’ll have substantial lead time between realizing cleaning is needed and actually requiring the filter, unlike thinner filters that reach capacity quickly.
What maintenance does the 4″ galvanized steel filter require?
Galvanized steel 4″ filters require the same simple maintenance as aluminum construction—periodic washing with water-based methods when dust accumulation becomes visible or when pressure drop reaches 0.50″ w.g.—but with dramatically extended intervals between cleanings due to maximum 9-ply capacity. Clean using garden hose, sink soaking (30-60 minute soak for deep penetration), commercial dishwasher, or pressure washer—ensure thorough rinsing of both faces of the deep 9-ply media (allow 60-120 minutes drying time). The hot-dip galvanized coating requires no special maintenance, maintaining corrosion protection throughout the 5-10 year service life. The galvanized construction tolerates aggressive cleaning without degradation. The maximum dust-holding capacity means you’ll perform far fewer total cleaning cycles over the filter’s service life compared to thinner alternatives—dramatically reducing cumulative maintenance labor and justifying the higher initial cost through exceptional long-term operational savings.
Why Choose the HIGS40 Custom 4″ Galvanized Steel Washable Mesh Filter?
Choosing the HIGS40 Custom 4″ Galvanized Steel Washable Mesh Filter eliminates the frustration and expense of searching for compatible replacement filters for HVAC systems with discontinued or non-standard dimensions while providing industrial-grade durability, enhanced corrosion resistance, elevated temperature capability, and dramatically extended cleaning intervals that aluminum construction and thinner filters cannot match. Whether you’re maintaining commercial kitchen equipment operating at sustained elevated temperatures with extreme heavy grease loading, supporting manufacturing facilities with high humidity and continuous extreme dust generation, servicing food processing plants requiring frequent washdown environments with severely limited maintenance access, or managing industrial systems where premature aluminum corrosion and impractical cleaning frequency have created unsustainable operational costs, this made-to-order galvanized steel solution with 9-ply maximum media provides permanent filtration precisely matched to your unique dimensional requirements and demanding operating conditions. The custom manufacturing process ensures perfect dimensional fit while hot-dip galvanized steel construction with maximum media depth ensures optimal performance, maximum service life in harsh environments, and practical maintenance intervals despite extreme heavy particulate challenge that would overwhelm thinner filter depths.
Built to the same rigorous quality standards as our stock HIG Series products, this custom filter features precision-engineered 9-ply media construction and UL 900 Class 1 certification with 325°F continuous temperature rating—50°F higher than aluminum’s limitation. The industry-standard 4″ nominal (3-3/4″ actual) depth profile fits the vast majority of HVAC filter tracks designed for 4-inch filters while the maximum dust-holding capacity extends cleaning intervals dramatically—potentially from monthly cycles (with 1″ filters) to quarterly or even annual intervals in moderate applications, transforming maintenance burdens into practical schedules. Made in USA with premium 24-gauge hot-dip galvanized steel frames and 30-gauge galvanized steel face grids, each custom filter is manufactured to your exact specifications with ±1/8″ tolerance, ensuring precise fit and optimal performance throughout its 5-10 year service life in demanding industrial and commercial applications with extreme continuous heavy particulate loading.
The permanent washable construction delivers exceptional long-term value compared to disposable alternatives—especially critical for custom sizes where finding compatible replacements creates ongoing frustration and expense and where galvanized steel’s enhanced durability extends service life significantly beyond aluminum in harsh operating conditions while the maximum dust-holding capacity reduces maintenance frequency dramatically, often transforming impractical weekly or monthly cleaning requirements into practical quarterly or annual schedules. Once you’ve placed your initial custom order, reordering identical galvanized steel 4″ filters is effortless through your online account, eliminating the need to re-measure or re-specify dimensions for future purchases. The 43% dust arrestance efficiency protects downstream HVAC components while the manageable pressure drop maintains acceptable system efficiency even with 9-ply media. Simple water-based cleaning when pressure drop reaches 0.50″ w.g. restores peak performance without expensive cleaning agents or professional services—but you’ll perform these cleanings far less frequently than with thinner filters, dramatically reducing cumulative maintenance labor over the filter’s service life—with hot-dip galvanized construction supporting repeated cleaning cycles throughout the filter’s multi-year service life without corrosion or degradation.
Facility managers, property owners, HVAC contractors, and industrial maintenance professionals choose the HIGS40 when standard filters cannot solve their combined dimensional, environmental, and maintenance filtration challenges and when operating conditions demand materials and dust-holding capacity exceeding aluminum’s and thinner filters’ limitations. From maintaining vintage industrial equipment with discontinued filter dimensions and severely limited maintenance access to supporting harsh manufacturing environments requiring enhanced corrosion resistance, 325°F temperature capability, and dramatically extended cleaning intervals, this custom galvanized steel mesh filter with 9-ply maximum media provides the permanent solution that eliminates filter procurement frustration while delivering industrial-grade filtration performance matched to your exact dimensional, environmental, and operational requirements. Invest in a custom-manufactured filter that fits your system perfectly, uses industrial-grade materials engineered for demanding conditions, provides maximum dust-holding capacity for dramatically extended maintenance intervals, delivers up to a decade of reliable service, and ensures you’ll never struggle to find compatible replacements again. Order your custom HIGS40 today and experience the confidence that comes from having a permanent filtration solution precisely matched to every aspect of your unique HVAC system requirements—with galvanized steel construction delivering the enhanced durability and temperature capability your demanding application requires, and with 4″ depth delivering the maximum cleaning interval extension your maintenance operations demand, transforming unsustainable maintenance burdens into practical, cost-effective service schedules.
Additional information
| Weight | 4 oz |
|---|---|
| Frame Material | Galvanized Steel |
| GTIN | 00840373527472 |
| MPN | HIGS40 |
Custom Mesh Filter, Stainless Steel, 4 Inch Thick
As low as $0.36 per sq inch
Please provide actual L x W measurements down to the 1/16th inch. Example: “15.25 x 24.1875”. Custom size filters are not returnable so please double check before ordering.
| 1/16 = .0625 | 9/16″ = .5625 |
| 1/8 = .125 | 5/8″ = .625 |
| 3/16 = .1875 | 11/16″ = .6875 |
| 1/4 = .25 | 3/4″ = .75 |
| 5/16 = .3125 | 13/16″ = .8125 |
| 3/8 = .375 | 7/8″ = .875 |
| 7/16 = .4375 | 15/16″ = .9375 |
| 1/2 = .5 | 1″ = 1 |
Description
Product Overview
The HISS40 Custom 4″ Stainless Steel Washable Mesh Filter delivers maximum dust-holding capacity and the longest cleaning intervals available in permanent industrial air filtration. Engineered with 9-ply Type 304 stainless steel media construction, this filter captures and holds 204 grams of particulate per square foot—triple the capacity of 1″ filters and 50% more than 2″ filters. The result is quarterly to annual cleaning intervals that dramatically reduce maintenance labor costs and minimize production disruptions.
Built to handle continuous 900°F operating temperatures, the HISS40 excels in the most demanding industrial environments: foundries with molten metal operations, commercial bakeries with high-temperature ovens, chemical processing facilities with corrosive atmospheres, and industrial drying applications. The 4″ nominal depth (3-3/4″ actual) with heavy-duty 24-gauge stainless steel frame construction provides structural rigidity essential for high-volume airflow systems.
Every HISS40 filter is custom-manufactured to your exact length and width specifications down to 1/16″, ensuring perfect fit in 4″ depth filter tracks. This made-to-order precision eliminates bypass leakage common with standard-size filters forced into non-standard openings. The extended media depth distributes dust loading evenly across all 9 plies, preventing rapid surface clogging and maintaining consistent airflow throughout the extended service interval.
The HISS40 represents the ultimate solution when maximum capacity justifies the investment—heavy particulate loading, difficult filter access, continuous dust generation, or remote equipment requiring minimal service. While the initial cost exceeds thinner alternatives, the combination of extended cleaning intervals (reducing labor costs by 75-90%), 5-10 year service life, and superior performance in extreme environments delivers compelling total cost of ownership advantages for demanding industrial applications.
Benefits
Key Benefits of the HISS40 Custom 4″ Stainless Steel Washable Mesh Filter
- Maximum Dust-Holding Capacity: 204 g/sq ft capacity—triple 1″ filters, 50% more than 2″ filters—enables quarterly to annual cleaning intervals and dramatically reduces maintenance labor costs
- Extreme Temperature Performance: 900°F continuous rating handles foundry operations, commercial bakeries, industrial dryers, and high-temperature processes that destroy standard filters
- Superior Corrosion Resistance: Type 304 stainless steel construction withstands chemical processing, coastal environments, food processing wash-downs, and corrosive industrial atmospheres
- Extended Service Life: 5-10 year operational life in extreme environments—far exceeding disposable filters while reducing waste and replacement frequency
- 9-Ply Media Construction: Triple the filtration surface area of 1″ filters distributes dust loading evenly, prevents rapid surface clogging, maintains consistent airflow
- Precision Custom Sizing: Manufactured to exact 1/16″ specifications for perfect fit in 4″ depth tracks, eliminating bypass leakage and ensuring filtration efficiency
- Heavy-Duty Frame: 24-gauge stainless steel frame with reinforced corners provides structural rigidity for high-volume airflow without flexing or warping at high temperatures
- Total Cost Advantage: Maximum capacity plus extended intervals plus long service life delivers lowest cost per hour of operation despite higher initial investment
Technical Specifications
| Specifications: | Details: |
|---|---|
| Model Number | HISS40 (Custom 4″ Stainless Steel) |
| Filter Depth | 4″ nominal (3-3/4″ actual depth) |
| Height & Width | Custom dimensions manufactured to your exact specifications |
| Dimensional Tolerance | ±1/8″ on height and width |
| Frame Material | 24-gauge Type 304 stainless steel |
| Filter Media | 9-ply corrugated criss-cross stainless steel screen wire mesh |
| Face Grid Material | 30-gauge Type 304 stainless steel |
| Frame Construction | Precision-mitered corners, stainless steel pop rivets |
| Drainage | 3 corner drain holes for complete water removal after washing |
| Maximum Operating Temperature | 900°F continuous (UL 900 Class 1 certified) |
| Dust Holding Capacity | 204 grams per square foot (triple 1″ capacity, 50% more than 2″) |
| Cleaning Interval | Quarterly to annual (varies by application) |
| Recommended Airflow Range | 300-500 FPM face velocity |
| Initial Pressure Drop | 0.15-0.25″ w.g. @ rated airflow (clean filter) |
| Recommended Final Resistance | 0.80-1.0″ w.g. (water gauge) before cleaning |
| Weight | Approximately 6.5 lbs (varies by custom dimensions) |
| Washability | Repeated cleaning cycles with water-based methods, aggressive detergents, caustic agents, or pressure washers |
| Service Life | 5-10 years with proper maintenance protocols |
| Custom Size Range | Minimum 8″ x 8″, Maximum 30″ x 48″ |
| Size Precision | Manufactured to 1/16″ tolerance |
| Track Requirement | 4″ nominal depth filter tracks required (will NOT fit 1″ or 2″ tracks) |
| Compliance & Certifications | UL 900 Class 1, ASTM E 2931 (washable filter standard) |
| Manufacturer | American Metal Filter Company (AMFCO) |
| Country of Origin | Made in USA |
Industrial Applications
Metal Casting & Foundry Operations
Foundries generate extreme particulate from molten metal pours, sand handling, grinding operations, and furnace emissions. The HISS40’s 204 g/sq ft capacity handles heavy dust loading while the 900°F rating withstands radiant heat from furnaces and molten metal operations. Quarterly cleaning intervals minimize production disruptions in 24/7 operations. Type 304 stainless steel resists corrosion from foundry chemical binders and maintains structural integrity despite continuous high-temperature exposure. The 9-ply media captures fine metallic particulate while maintaining airflow for critical ventilation systems protecting workers from metal fumes and silica dust.
Commercial Bakery & Food Processing
Commercial bakeries with high-capacity ovens generate continuous flour dust and operate at temperatures that destroy standard filters. The HISS40 handles 900°F continuous temperatures near oven exhaust systems while capturing fine flour particulate across 9 media plies. Stainless steel construction meets food-grade requirements and withstands frequent washdowns with sanitizing chemicals. Extended quarterly cleaning intervals reduce contamination risk from maintenance activity in food production areas. The filter’s capacity prevents rapid clogging from flour dust clouds during mixing and handling operations, maintaining consistent ventilation critical for worker safety and product quality.
Chemical Processing & Manufacturing
Chemical plants expose filters to corrosive vapors, process dust, and elevated temperatures that rapidly destroy aluminum or galvanized alternatives. Type 304 stainless steel provides superior corrosion resistance against acids, alkalis, and organic solvents common in chemical processing. The 900°F rating handles reactor vessel ventilation, dryer exhaust, and process off-gas systems. Annual cleaning intervals are achievable in many applications, minimizing exposure of maintenance personnel to chemical atmospheres. The 9-ply construction prevents chemical-laden particulate from penetrating to inner layers, simplifying cleaning and maintaining filtration efficiency throughout extended intervals.
Industrial Drying & Curing Operations
Industrial dryers for textiles, lumber, coatings, and manufacturing processes operate continuously at elevated temperatures while generating substantial particulate. The HISS40’s 900°F rating handles dryer exhaust temperatures while the 204 g/sq ft capacity manages heavy dust loading from dried products. Quarterly maintenance intervals minimize downtime for continuous drying operations. The stainless steel construction withstands moisture-to-dry cycling that causes corrosion in galvanized frames. The extended media depth distributes lint, fiber, and product dust across 9 plies, preventing rapid surface loading that restricts airflow and reduces drying efficiency.
Powder Coating & Industrial Painting
Powder coating operations generate fine particulate overspray requiring high-efficiency filtration to protect workers and maintain coating quality. The HISS40’s 9-ply media captures submicron powder particulate while the 900°F rating handles curing oven exhaust ventilation. Stainless steel won’t contaminate powder coating or painting operations with rust particles that cause finish defects. The maximum capacity handles continuous production shifts with quarterly cleaning schedules, while the washable design allows complete powder removal for color changeovers. Type 304 stainless resists chemical solvents used in cleaning and paint prep operations, providing reliable performance in demanding finishing environments.
Material Selection Guide
Stainless Steel (HIS Series – 900°F) vs. Galvanized Steel (HIG Series – 325°F)
Choose stainless steel HISS40 when operating temperatures exceed 325°F, when corrosive atmospheres attack galvanized coatings, or when food-grade materials are required. The 575°F temperature advantage enables use near furnaces, ovens, dryers, and high-temperature industrial processes. Stainless steel maintains 5-10 year service life in chemical processing, coastal environments, and applications with frequent washdowns where galvanized coatings would fail. The higher initial investment is justified when extreme conditions would cause premature galvanized filter failure or when extended service life in harsh environments reduces total cost of ownership.
Stainless Steel (HIS Series – 900°F) vs. Aluminum (HIA Series – 275°F)
The HISS40 provides 625°F higher temperature capability than aluminum alternatives, essential for high-temperature industrial processes. Choose stainless when temperatures exceed 275°F, when superior corrosion resistance justifies the cost premium, or when structural rigidity at elevated temperatures is critical. While aluminum offers cost savings for standard applications, stainless steel delivers reliable performance in foundries, commercial bakeries, chemical plants, and industrial dryers where aluminum would soften, corrode, or fail. Both materials provide 5-10 year service life, but stainless achieves this longevity in far more demanding environments.
Custom Sizing Advantages
Custom-sized HISS40 filters eliminate bypass leakage by fitting precisely into non-standard filter openings common in industrial equipment. Standard size filters forced into oversized tracks allow unfiltered air to bypass the media, reducing filtration efficiency and exposing downstream equipment to damage. Made-to-order manufacturing ensures exact fit to 1/16″ tolerance, maximizing the 9-ply media’s filtration capability. For equipment with difficult filter access or remote installations, custom sizing enables optimal performance with extended intervals, minimizing maintenance trips to hard-to-reach locations.
Depth Comparison & Selection Guide
Understanding Filter Depth Impact on Performance
Filter depth directly determines dust-holding capacity and cleaning interval length. The HISS40 (4″ depth, 9-ply) holds 204 g/sq ft—triple the 68 g/sq ft of 1″ filters (5-ply) and 50% more than the 136 g/sq ft of 2″ filters (7-ply). This capacity advantage translates to proportionally longer intervals: where a 1″ filter requires bi-weekly cleaning, a 2″ filter extends to monthly cleaning, and the 4″ HISS40 achieves quarterly or annual intervals. The cost premium for greater depth is offset by reduced labor costs and extended service life in the most demanding applications.
When to Choose 1″ Depth (HISS10)
Select 1″ stainless filters when filter tracks are limited to 1″ nominal depth, when moderate particulate loading doesn’t justify the cost of deeper alternatives, or when monthly cleaning schedules are acceptable. The 1″ profile fits most standard HVAC equipment and provides excellent performance in many industrial applications. While requiring more frequent cleaning than deeper filters, the 1″ HISS10 offers the lowest initial cost entry point to washable stainless steel filtration with 900°F capability.
When to Choose 2″ Depth (HISS20)
The 2″ HISS20 offers the optimal balance of capacity and cost for many installations. With double the dust-holding capacity of 1″ filters, the 2″ depth extends cleaning intervals by 80-100% while adding only modest cost over the 1″ alternative. Choose 2″ depth when you have 2″ filter tracks available, when particulate loading causes 1″ filters to require cleaning more than monthly, or when labor costs for frequent maintenance are significant. The 2″ depth provides excellent value for moderate to heavy dust loading applications.
When to Choose 4″ Depth (HISS40)
The HISS40 represents the ultimate capacity solution justified by specific operational demands: (1) Heavy continuous particulate loading requiring maximum capacity to achieve quarterly or annual cleaning intervals, (2) Difficult filter access locations where minimizing maintenance trips justifies higher initial cost, (3) Remote or elevated equipment where extended intervals reduce safety risks and access costs, (4) Applications where the labor cost of frequent cleaning exceeds the HISS40’s cost premium, or (5) Critical systems where extended reliable operation between services is paramount. While the 4″ depth carries the highest initial cost, it delivers the lowest cost per hour of operation in heavy-duty applications by maximizing the interval between expensive maintenance activities.
Track Compatibility Requirements
Critical consideration: The 4″ nominal depth HISS40 (3-3/4″ actual) requires 4″ depth filter tracks. It will NOT fit in 1″ or 2″ tracks. Before ordering, verify your equipment has 4″ nominal depth track capacity. Measure the existing filter track opening from front face to rear face—it should be approximately 3-7/8″ to 4″ to accommodate the HISS40. If you’re uncertain about track depth, consult equipment documentation or contact technical support. Installing a 4″ filter in undersized tracks is impossible, while installing thinner filters in 4″ tracks reduces efficiency and may cause rattling or improper sealing.
Construction Features
9-Ply Stainless Steel Media Construction
The HISS40 features 9 layers of woven Type 304 stainless steel mesh, providing triple the filtration surface area of 1″ filters (5-ply) and 50% more than 2″ filters (7-ply). This expanded media pack distributes particulate loading evenly across all layers, preventing rapid surface clogging that restricts airflow. Each ply captures progressively finer particulate as air moves through the media depth, achieving high efficiency while maintaining low resistance. The additional plies enable the 204 g/sq ft capacity—the highest in the HIS Series—translating directly to extended cleaning intervals. The multiple-layer design also provides redundancy: even if outer plies become heavily loaded, inner layers continue effective filtration until scheduled cleaning.
Heavy-Duty 24-Gauge Frame
The HISS40 frame is constructed from 24-gauge Type 304 stainless steel sheet—heavier than the 26-gauge frames used in 1″ and 2″ filters. This increased gauge provides structural rigidity essential for the 9-ply media pack and high-volume airflow systems. The frame maintains dimensional stability even at 900°F operating temperatures, preventing warping that would compromise sealing. Reinforced corner construction with welded joints eliminates weak points where frames might separate under repeated thermal cycling. The heavy-duty design supports the filter’s greater weight (approximately 6.5 lbs) without flexing during handling or installation.
30-Gauge Face Grids
Both intake and exhaust faces feature 30-gauge stainless steel support grids that protect the 9-ply media from physical damage while maintaining open area for airflow. The grid pattern distributes load evenly across the media pack, preventing sagging or compression of the extended depth construction. The grids also provide electrical grounding paths important in static-prone environments. Face grids are permanently attached during manufacturing, ensuring the media remains properly positioned throughout the filter’s 5-10 year service life.
Type 304 Stainless Steel Material Properties
Type 304 stainless steel provides superior corrosion resistance through its chromium-nickel composition (18% chromium, 8% nickel). This austenitic stainless maintains strength and ductility across the full operating range from ambient to 900°F. Unlike galvanized steel which loses its protective zinc coating at high temperatures, Type 304’s corrosion resistance is intrinsic to the material itself. The non-magnetic properties of Type 304 are advantageous in applications sensitive to magnetic fields. Food-grade classification makes Type 304 suitable for bakery and food processing applications. The material’s excellent formability enables the complex geometry of the 9-ply media construction.
Continuous Weld Construction
All frame joints use continuous TIG (Tungsten Inert Gas) welding rather than spot welding, ensuring complete structural integrity and preventing leakage paths at corners. The continuous welds maintain strength at elevated temperatures where spot welds might fail. Welded construction eliminates mechanical fasteners that could corrode or loosen during thermal cycling. The welds are ground smooth to prevent sharp edges during handling. This construction method provides the structural integrity required for 5-10 year service life in demanding industrial environments with daily thermal cycling and high differential pressures.
Maintenance & Cleaning
Extended Cleaning Intervals
The HISS40’s 204 g/sq ft capacity enables quarterly cleaning intervals in most industrial applications, with some facilities achieving annual cleaning schedules in lighter-duty installations. This represents a dramatic reduction from monthly or bi-weekly cleaning required for 1″ filters, or monthly to quarterly intervals for 2″ filters. Extended intervals reduce labor costs by 75-90%, minimize production disruptions from maintenance activities, and decrease exposure of maintenance personnel to industrial atmospheres. Monitor differential pressure across the filter to optimize cleaning schedules for your specific application—clean when pressure drop reaches 0.8″ to 1.0″ w.g. or per equipment manufacturer specifications.
Cleaning Methods for 4″ Depth Filters
Proper cleaning of the HISS40’s 9-ply construction requires attention to the extended media depth. Soak the filter in warm water (120-140°F) with appropriate detergent for 30-60 minutes—substantially longer than the 20-40 minutes required for 2″ filters or 15-30 minutes for 1″ filters. The extended soak time ensures cleaning solution penetrates completely through all 9 media layers, dissolving oils and loosening embedded particulate. For heavily loaded filters, use a soft brush to work cleaning solution through the media from both faces. Rinse thoroughly with clean water from both sides until runoff is clear, ensuring removal of all detergent and loosened particulate from the extended depth.
Drying Requirements
After rinsing, allow the HISS40 to drain for 15-20 minutes in a vertical orientation before final drying. The 9-ply construction holds more water than thinner filters, requiring extended drain time. Air dry the filter completely before reinstallation—moisture trapped in the deep media pack can cause efficiency loss and may promote microbial growth in some environments. In industrial settings, compressed air can accelerate drying by blowing through the media from the clean side, but use moderate pressure (30-40 PSI) to avoid damaging the media structure. Complete drying typically requires 2-4 hours depending on ambient conditions.
Inspection After Cleaning
After each cleaning cycle, inspect the HISS40 for media damage, frame distortion, or degraded welds. Check that all 9 media plies remain intact without tears, punctures, or separation. Verify the frame maintains dimensional accuracy—measure length and width to ensure the filter still fits properly in the track. Inspect corner welds for cracks or separation. Check face grids for deformation. The filter should maintain its original dimensions and structural integrity throughout its 5-10 year service life. If inspection reveals damage, the increased depth and weight of 4″ filters may complicate repairs—consult the manufacturer regarding refurbishment options.
Handling Considerations
The HISS40’s approximate 6.5 lb weight and extended 4″ depth require careful handling during removal, cleaning, and reinstallation. Two-person handling may be advisable for larger sizes to prevent dropping or damaging the filter. The greater weight increases momentum during handling, making the filter more difficult to maneuver in tight equipment spaces. When removing heavily loaded filters, expect additional weight from accumulated particulate—a fully loaded HISS40 may weigh 8-9 lbs. Use appropriate personal protective equipment when handling filters loaded with industrial particulate, especially in chemical processing or foundry applications.
Installation
Verify 4″ Track Compatibility
Before ordering the HISS40, verify your equipment has 4″ nominal depth filter tracks. Measure the filter track opening from the front face to the rear face—it should be approximately 3-7/8″ to 4″ to accommodate the 3-3/4″ actual depth of the HISS40. The filter will NOT fit in 1″ (7/8″ actual) or 2″ (1-3/4″ actual) tracks. If you’re replacing existing filters, verify they are currently 4″ nominal depth. For new installations or track modifications, ensure the HVAC system design accounts for the 4″ depth requirement. Installing undersized filters in 4″ tracks reduces efficiency and creates bypass leakage.
Custom Size Ordering
Measure your filter opening precisely to 1/16″. The HISS40 is manufactured to your exact specifications for length and width. Measure the filter track opening (the space where the filter slides) rather than the existing filter—old filters may have shrunk or expanded. For replacement applications, measure the track opening in multiple locations and use the smallest dimension to ensure fit. Record dimensions as Length x Width. Common dimension formats: 15.25″ x 24.1875″ or 20.0625″ x 25.75″. Custom sizes are non-returnable, so verify measurements carefully before ordering.
Installation Procedure
Slide the HISS40 into the 4″ filter track with the media plies perpendicular to airflow direction. The filter can be installed in any orientation—horizontal, vertical, or angled—as the rigid stainless steel construction prevents sagging regardless of position. Ensure the filter seats completely into the track with frame edges flush against track stops. The custom sizing should provide a snug fit that eliminates bypass gaps. For applications with high differential pressure or significant vibration, verify the track includes retention hardware to prevent the filter from dislodging. Check that the filter doesn’t obstruct dampers, sensors, or other equipment within the air handling unit.
Initial Startup
After installation, start the HVAC system and verify proper airflow. Monitor initial differential pressure across the HISS40—expect low pressure drop (typically 0.15-0.25″ w.g. for a clean filter depending on face velocity). Check for air leaks around the filter perimeter indicating improper seating or incorrect dimensions. Listen for rattling or vibration suggesting inadequate retention. Verify the 9-ply media remains stable without excessive movement. During the first week of operation, recheck differential pressure daily to establish baseline performance. This baseline helps optimize future cleaning schedules based on the rate of pressure increase in your specific application.
Pressure Drop Monitoring
Install differential pressure gauges (manometers) across the filter to monitor loading condition. The HISS40’s extended capacity means pressure drop increases slowly over the quarterly to annual service interval. Clean the filter when differential pressure reaches 0.8-1.0″ w.g. (or per equipment manufacturer specifications) to maintain energy efficiency and system performance. The 9-ply construction provides relatively gradual pressure increase as dust loading progresses—avoid letting pressure exceed 1.5″ w.g. as this indicates heavy loading that may be difficult to clean completely. Regular monitoring optimizes the balance between extended intervals and cleaning effectiveness.
Performance Optimization
Maximizing Cleaning Intervals
The HISS40’s 204 g/sq ft capacity delivers quarterly to annual intervals when properly matched to application particulate loading. To maximize intervals: (1) Install pre-filters upstream to capture larger particulate before it reaches the HISS40, (2) Optimize HVAC system airflow to operate at design face velocity (typically 300-500 FPM) rather than excessive velocity that overloads filters, (3) Address particulate sources where possible to reduce overall loading, (4) Clean filters before differential pressure becomes excessive—heavily loaded media is harder to clean completely, reducing capacity after cleaning. Facilities that implement these practices consistently achieve the longest intervals and maximum filter life.
System Integration
The HISS40 performs optimally as the final filter stage in multi-stage filtration systems. Use disposable pre-filters (MERV 8-11) or washable aluminum/galvanized filters upstream to capture larger particulate (>10 microns), protecting the HISS40 from rapid loading with coarse dust. This filtration strategy extends HISS40 cleaning intervals while the stainless construction handles the high-temperature or corrosive atmosphere that would destroy pre-filters. The 9-ply stainless media then captures finer particulate (down to 5-10 microns) requiring the extended capacity. This staged approach maximizes the total system capacity while optimizing the cost-performance balance.
Temperature Management
While the HISS40 handles 900°F continuous operation, lower temperatures reduce thermal stress and may extend the 5-10 year service life toward the upper end of the range. Where possible, install filters in locations with lower ambient temperatures or allow exhaust gases to cool before filtration. However, don’t compromise ventilation effectiveness to reduce filter temperature—the HISS40 is specifically designed for high-temperature applications where temperature reduction isn’t feasible. The Type 304 stainless steel maintains full strength and corrosion resistance throughout the rated temperature range.
Face Velocity Considerations
Optimal performance occurs at face velocities of 300-500 FPM. Higher velocities (>600 FPM) increase pressure drop and may reduce dust-holding capacity as particulate impacts the surface with greater force, causing deeper penetration into the 9-ply media. Lower velocities (<200 FPM) are acceptable and may slightly extend capacity, but ensure they meet ventilation requirements. The HISS40’s extended depth provides more tolerance for velocity variation than thinner filters. Consult HVAC system design documentation for target face velocity, or calculate it from measured CFM and filter face area (FPM = CFM ÷ face area in square feet).
Cost-Benefit Analysis
Total Cost of Ownership
The HISS40’s higher initial cost is offset by dramatic operational savings over its 5-10 year service life. Consider: (1) Labor cost reduction—quarterly or annual cleaning versus monthly or bi-weekly for thinner filters reduces labor by 75-90%, (2) Production uptime—extended intervals mean fewer maintenance shutdowns and disruptions, (3) Energy savings—the 9-ply construction maintains lower pressure drop when clean compared to equivalently loaded thinner filters, (4) Disposal elimination—washable design eliminates ongoing disposable filter costs and waste disposal fees, (5) Extended service life—5-10 years in extreme environments provides reliable performance long after alternatives would require replacement.
When the HISS40 Investment is Justified
The 4″ depth premium is justified when: Heavy continuous particulate loading causes thinner filters to require cleaning more than monthly; Filter access is difficult, elevated, or requires production shutdown making each maintenance visit expensive; Remote equipment locations make frequent maintenance trips impractical; Labor costs are high relative to filter cost; Applications involve temperatures exceeding 325°F (precluding galvanized) or corrosive atmospheres (precluding aluminum); Critical systems requiring maximum reliability benefit from the redundancy of 9-ply construction; or when calculating total cost per operating hour rather than initial purchase price.
Comparison to Disposable Alternatives
Disposable filters for high-temperature or industrial applications may cost $30-80 each depending on size and specification. At monthly replacement intervals, annual disposable costs reach $360-960 plus labor and waste disposal. The HISS40’s initial cost is recovered within 18-36 months through elimination of recurring purchases, after which operational savings accumulate for the remaining 3-8 years of service life. In extreme environments (>500°F, corrosive atmospheres), disposable alternatives may fail in days or weeks, making washable stainless steel the only economically viable solution.
Safety & Compliance
High-Temperature Safety
The HISS40’s 900°F continuous rating enables safe operation in high-temperature exhaust systems, but proper system design is essential. Ensure ductwork and mounting hardware are also rated for the operating temperature. Verify the filter location allows adequate access for maintenance without exposing personnel to extreme temperatures—provide cool-down periods or isolation before filter service. Use appropriate personal protective equipment when handling filters that may be hot from recent operation. The stainless steel construction won’t contribute to fire hazards unlike filters with organic components.
Food Processing Compliance
Type 304 stainless steel meets FDA requirements for food contact surfaces, making the HISS40 appropriate for commercial bakery and food processing applications. The washable design supports sanitation protocols requiring regular cleaning with food-safe detergents. Stainless steel won’t shed rust particles that could contaminate products. For food processing applications, establish cleaning frequencies that meet facility sanitation schedules, which may be more frequent than the intervals dictated purely by dust loading.
Worker Protection
Proper filtration protects workers from airborne particulate hazards including metal fumes, flour dust, chemical particulate, and respirable dust. The HISS40’s extended capacity maintains effective filtration throughout the interval between cleanings, ensuring consistent worker protection. Monitor differential pressure to ensure cleaning occurs before excessive loading compromises filtration efficiency. When handling filters loaded with hazardous particulate, use appropriate respiratory protection, gloves, and eye protection during removal and cleaning operations.
Complementary Products
For multi-stage filtration systems, consider pairing the HISS40 with other custom stainless steel filters for optimal performance throughout your extreme environment HVAC system.
Frequently Asked Questions
Why choose a 4″ stainless steel filter over 1″ or 2″ depths?
The 4″ HISS40 delivers maximum dust-holding capacity at 204 g/sq ft—triple the capacity of 1″ filters and 50% more than 2″ filters. This translates to quarterly or even annual cleaning intervals versus bi-weekly or monthly for thinner filters. Choose 4″ depth when you have heavy particulate loading, difficult filter access requiring minimal maintenance trips, continuous dust generation, or remote equipment. The higher initial cost is justified by dramatically reduced labor costs and extended service life in demanding applications.
What maintenance procedures are different for 4″ depth filters?
Cleaning 4″ filters requires longer soak times (30-60 minutes versus 20-40 for 2″ or 15-30 for 1″) to ensure complete media penetration. Use warm water (120-140°F) with appropriate detergent, and ensure the cleaning solution reaches all 9 media layers. After rinsing, allow extended drain time (15-20 minutes) and verify complete drying before reinstallation. The heavier weight (approximately 6.5 lbs) may require two-person handling.
Why Choose the HISS40 Custom 4″ Stainless Steel Washable Mesh Filter?
The HISS40 represents the ultimate solution when maximum capacity justifies the investment—heavy particulate loading, difficult filter access, continuous dust generation, or remote equipment requiring minimal service. With 900°F continuous temperature rating, unmatched corrosion resistance, and quarterly to annual cleaning intervals, this custom stainless steel filter delivers compelling total cost of ownership advantages for the most demanding industrial applications. Made to your exact specifications with premium Type 304 stainless steel construction, the HISS40 ensures you never struggle to find compatible replacement filters while achieving maximum performance in extreme environments.
Ordering Information
Custom Size Specifications
Provide exact filter dimensions to 1/16″ precision. Measure the filter track opening (not an existing filter) at multiple points and use the smallest dimension. Specify dimensions as Length x Width in inches. Use decimal equivalents for fractional measurements: 1/16 = .0625, 1/8 = .125, 3/16 = .1875, 1/4 = .25, 5/16 = .3125, 3/8 = .375, 7/16 = .4375, 1/2 = .5, 9/16 = .5625, 5/8 = .625, 11/16 = .6875, 3/4 = .75, 13/16 = .8125, 7/8 = .875, 15/16 = .9375. Example: 20.25″ x 25.1875″. Size range: minimum 8″ x 8″, maximum 30″ x 48″.
Lead Time
The HISS40 is custom-manufactured to order. Typical lead time is 2-4 weeks depending on size and quantity. Rush production may be available for emergency replacements—contact customer service for expedited options. Plan ahead for initial orders or seasonal maintenance to ensure filters arrive when needed. For facilities with multiple filter locations, consider ordering all sizes simultaneously to optimize production scheduling.
Minimum Order
Custom HISS40 filters can be ordered individually with no minimum quantity requirement. However, ordering multiple filters for a facility simultaneously may provide cost advantages through production efficiency. For large facilities with numerous filter locations, contact sales for volume pricing on complete facility requirements.
Returns Policy
Custom-sized filters manufactured to specific dimensions are non-returnable. Verify all measurements carefully before ordering. If you receive a filter that doesn’t match your specified dimensions, contact customer service immediately—manufacturing errors are covered by warranty. Keep original order documentation showing specified dimensions for reference.
Technical Support
For assistance with filter selection, sizing, or application-specific questions, contact AMFCO technical support. Provide information about operating temperature, particulate type, airflow rate, available track depth, and current filter performance to receive recommendations optimized for your application. Technical support can help determine whether the HISS40’s maximum capacity justifies the investment for your specific conditions or whether the HISS10 or HISS20 provides better value.
Additional information
| Weight | 104.0 oz |
|---|---|
| Frame Material | 304 Stainless Steel |
| GTIN | 00840373527410 |
| MPN | HISS40 |


